1991 Ford F-150

High concern

Owners filed 304 complaints about this vehicle with federal regulators, most often about the fuel system, gasoline › storage › tank assembly. It has been recalled 6 times.

When it fails
020k40k60k90k120k200k

39 complaints record an odometer reading. Failures cluster around 120,000150,000 miles; the median is 107,000 miles.

What fails
ComponentReportsCrashesFiresInjuries
Fuel System, Gasoline › Storage › Tank Assembly43
021
Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices42
000
Fuel System, Gasoline › Storage › Auxillary Tank20
000
Electrical System › Ignition › Switch19
0130
Fuel System, Gasoline18
010
Service Brakes, Hydraulic › Antilock/Traction Control/Electronic Limited Slip11
100
Fuel System, Gasoline › Delivery › Fuel Pump10
000
Tires › Tread/Belt9
000
Vehicle Speed Control7
201
Engine and Engine Cooling › Engine › Gasoline6
030

6 safety recalls

Part 573 reports
Fuel System, Gasoline01I008000
Filed Jul 19, 20011,556,221 vehiclesFord Motor Company

Defect. THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN THE FUEL PUMP/SENDER ASSEMBLY. FUEL MAY BE SUPPLIED FROM ONE TANK AND SOME OR ALL OF THE UNUSED FUEL MAY BE RETURNED TO THE OTHER TANK.

Risk. SHOULD THIS OCCUR, THE CAPACITY OF THE RECEIVING TANK MAY BE EXCEEDED AND FUEL MAY OVERFLOW FROM THE FILLER CAP.

Remedy. FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE ALREADY HAS MORE THAN 150,000 MILES, THIS OVERAGE WILL LAST UNTIL DECEMBER 31, 2001. IF THE VEHICLE IS EXPERIENCING A FUEL CROSS-FLOW CONDITION, DEALERS WILL REPAIR THE CONDITION FREE OF CHARGE.

Tires › Tread/Belt01X001000
Filed May 22, 200113,000,000 vehiclesFord Motor Company

Defect. THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. EQUIPMENT DESCRIPTION: FORD IS REPLACING ALL FIRESTONE WILDERNESS AT 15, 16, AND 17 INCH TIRES MOUNTED ON FORD TRUCKS AND SUVS. FORD REPORTS TREAD SEPARATION CAN OCCUR DUE TO A COMBINATION OF THE SENSITIVITY OF THE TIRE DESIGN TO STRESS, AGING, AND MANUFACTURING DIFFERENCES BETWEEN PLANTS. FORD IS REPLACING THESE TIRES TO PREVENT POSSIBLE PREMATURE TIRE FAILURE. VEHICLE DESCRIPTION: THE VEHICLES LISTED BELOW MAY HAVE BEEN ORIGINALLY EQUIPPED WITH FIRESTONE WILDERNESS AT TIRES OR MAY HAVE HAD WILDERNESS AT TIRES INSTALLED DURING THE FIRESTONE RECALL LAUNCHED IN AUGUST 2000. CERTAIN 1991 THROUGHT 2002 FORD EXPLORER CERTAIN 2001 THROUGHT 2002 EXPLORER SPORT, AND SPORT TRAC CERTAIN 1997 THROUGH 2002 MERCURY MOUNTAINEER CERTAIN 1991 THROUGH 2001 RANGER CERTAIN 1999 THROUGH 2001 EXPEDITION CERTAIN 1991 THROUGH 1994, AND 1997 MODEL YEAR F-SERIES CERTAIN 1991 THROUGH 1994 BRONCO NOTE: BOTH ORIGINAL EQUIPMENT AND REPLACEMENT TIRES ARE AFFECTED.

Risk. SHOULD THE TREAD SEPARATE AT HIGHWAY SPEEDS, A VEHICLE CRASH COULD OCCUR, POSSIBLY RESULTING IN PERSONAL INJURY OR DEATH.

Remedy. THE REPLACEMENT/REIMBURSEMENT PROGRAM FOR THIS CAMPAIGN EXPIRED ON MARCH 31, 2002. HOWEVER, CUSTOMERS CAN CONTACT FORD AT 1-877-917-3673 OR GO ON-LINE TO WWW.FORD.COM FOR POSSIBLE ASSISTANCE.

Tires › Tread/Belt00T005000
Filed Aug 21, 200014,400,000 vehiclesBridgestone/Firestone, Inc.

Defect. TIRE DESCRIPTION: FIRESTONE WILDERNESS AT, SIZE P235/75R15, PRODUCED AT THE DECATUR, ILLINOIS TIRE PLANT AND ALL FIRESTONE RADIAL ATX AND RADIAL ATX II TIRES, SIZE P235/75R15. OPERATION OF THESE TIRES AT LOW INFLATION PRESSURES, HIGH SPEED, AND IN HOT WEATHER, CAN CONTRIBUTE TO SEPARATION OF THE TIRE TREAD.

Risk. IF THE TREAD SEPARATES FROM THE TIRE, THE DRIVER CAN LOSE CONTROL OF THE VEHICLE, POSSIBLY RESULTING IN A CRASH CAUSING INJURY OR DEATH.

Remedy. THE REPLACEMENT/REIMBURSEMENT PROGRAM FOR THIS CAMPAIGN EXPIRED ON AUGUST 29, 2001. HOWEVER, CUSTOMERS SHOULD CONTACT FIRESTONE CUSTOMER SERVICE AT 1-800-465-1904 FOR POSSIBLE ASSISTANCE.

Electrical System › Ignition96V071000
Filed Apr 25, 19967,900,000 vehiclesFord Motor Company

Defect. THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Risk. THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy. DEALERS WILL REPLACE THE IGNITION SWITCH.

Fuel System, Gasoline › Storage › Tank Assembly93V125000
Filed Aug 2, 19931,131,000 vehiclesFord Motor Company

Defect. A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Risk. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy. REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

Steering › Steering Wheel/Handle Bar93V066000
Filed Apr 27, 19932,419 vehiclesFairmont Tamper

Defect. KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.

Risk. THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.

Remedy. A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.

What owners reported

Newest filings
Fuel System, Gasoline
Filed Apr 8, 2025112,000 milesCA

The contact owns a 1991 Ford F-150. The contact stated that while driving at an undisclosed speed, the rear fuel tank gauge began indicating that the rear tank was losing fuel abnormally fast. After a visual inspection, the contact observed that fuel was flowing from the rear fuel tank into the front fuel tank. No warning lights were illuminated. The vehicle was taken to the dealer, who diagnosed a failure with the fuel pump assembly check valve; however, the dealer declined to attempt to repair the vehicle due to the age of the vehicle. The vehicle was not repaired. After investigating the failure, the contact related the failure to NHTSA Campaign Number: 93V125000 (Fuel System, Gasoline), but was unaware if the VIN was ever included in the recall. The manufacturer was notified of the failure, a case was opened, and the contact was later informed that the VIN was included in the recall and had been repaired already. The failure mileage was 112,000.

Electrical System
Filed Mar 29, 202183,100 milesKY

THE TRUCK WONT CRANK. WHEN THE KEY IS TURNED OFF AND REMOVED SOME ELECTRICAL SYSTEMS STILL WORK AND CAUSE SMOKING. I HAVE HAD TO DISCONNECT THE BATTERY IN FEAR THE TRUCK WILL BURN DOWN. FORD WAS CONTACTED ABOUT THE ISSUE AND SAID THEY CANT DO ANYTHING BECAUSE THEIR RECORDS FOR RECALLS ONLY GO 10 YEARS. EVEN THOUGH THE TRUCK HAS LESS THAN 84000 MILES ON IT.

Fuel/Propulsion System
Filed Jan 6, 2017TX

FUEL SPILLING OUT AROUND NECK WHILE PARKED AT WORK, ALSO REAR FUEL TANK PUMPING GAS INTO FRONT GAS TANK WHILE DRIVING.... *TR

Fuel System, Gasoline
Filed Oct 18, 2016123,000 milesNE

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT ONE OF THE TANKS IN THE VEHICLE WOULD NOT WORK AND CAUSED THE VEHICLE TO STALL. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC, BUT COULD NOT BE REPAIRED. THE DETAILS OF THE DIAGNOSTIC TEST COULD NOT BE PROVIDED. THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 01L008000 (FUEL SYSTEM, GASOLINE). THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 123,000. UPDATED 01/05/17*LJ

Fuel/Propulsion System
Filed Apr 6, 201646,300 milesFL

WHILE THE ENGINE IS RUNNING, THE DUAL TANKS CROSS-FLOW INTO ONE ANOTHER. ONE TANK HAS OVER-FILLED THE OTHER TANK AND VISA VERSA TO INCLUDE SPILLAGE. I HAVE CONTACTED THE LOCAL DEALER AND FORD ABOUT IT BUT THEY SAY THEY CAN'T DO ANYTHING FOR ME AS FAR AS A RECALL IS CONCERNED EVEN THOUGH THIS ISSUE WAS A SAFETY RECALL ISSUE IN THE PAST. I DO NOT KNOW IF THE PREVIOUS OWNER ADDRESSED THE RECALL BUT IT IS A PROBLEM RIGHT NOW. WHEN I PURCHASED THE TRUCK, I DIDN'T KNOW IT HAD A CROSS-FLOW PROBLEM UNTIL SOMEONE TOLD ME SOMETHING WAS LEAKING FROM UNDER MY TRUCK. SINCE THEN, I HAVE NOTICED THAT THE FUEL GAUGE GOES DOWN QUICKER THAN IT SHOULD AND WHEN I SWITCH TANKS, THE OTHER TANK HAS MORE FUEL THAN IT DID. THIS ISSUE HAPPENS REGARDLESS IF IN MOTION OR STANDING STILL. IF THE TRACK WAS FIXED VIA A RECALL, THEY OBVIOUSLY DIDN'T DO IT RIGHT OR THE "FIX" DIDN'T FIX THE PROBLEM. I CAN NOT AFFORD TO FIX THIS ISSUE EVEN THOUGH IT SHOULD HAVE BEEN FIXED THROUGH THE RECALL ALREADY.

Fuel System, Gasoline
Filed May 12, 201496,000 milesGA

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT THE FUEL PUMP ASSEMBLY CAUSED A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THE FAILURE OCCURRED, THE CAPACITY OF THE SECOND TANK WAS EXCEEDED AND WOULD CAUSE FUEL SPILLAGE. THE CONTACT BELIEVED THAT THE VEHICLE WAS EXHIBITING THE EXACT SAME FAILURE INDICATED IN NHTSA CAMPAIGN NUMBER: 93V125000. (FUEL SYSTEM, GASOLINE). THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE CONTACT WAS INFORMED THAT THE VEHICLE WAS NOT INCLUDED IN THE RECALL CAMPAIGN. THE FAILURE AND CURRENT MILEAGE WAS 96,000.

Fuel/Propulsion System
Filed Apr 7, 201477,000 milesTX

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS BEING RETURNED TO THE SECOND TANK, CAUSING A FUEL SPILLAGE. THE CONTACT ALSO STATED THAT THE FUEL PRESSURE WAS LOW. THE CONTACT WAS NOT DIAGNOSED. THE MANUFACTURE WAS MADE AWARE OF THE FAILURE AND STATED THE VEHICLE WAS SERVICED UNDER RECALL NHTSA CAMPAIGN NUMBER: 01I008000(FUEL SYSTEM, GASOLINE) HOWEVER THE FAILURE PERSISTED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 77,000.

Fuel System, Gasoline › Delivery › Fuel Pump
Filed Jul 16, 2013145,000 milesTX

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT THE VEHICLE FAILED TO START. THE VEHICLE WAS TOWED TO THE DEALER WHO STATED THE FUEL PUMP FAILED. THE VEHICLE WAS REPAIRED BUT THE FAILURE RECURRED. THE MANUFACTURER WAS CONTACTED ABOUT THE FAILURE. THE FAILURE MILEAGE WAS 145,000. THE CONSUMER STATED THE BATTERY FAILED AND THE SEAL AROUND THE SPEEDOMETER WENT BAD.

Fuel System, Gasoline
Filed May 24, 2013130,000 milesIN

TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS BEING RETURNED TO THE SECOND TANK, CAUSING FUEL SPILLAGE. THE VEHICLE WAS TAKEN TO THE DEALER WHERE IT WAS DIAGNOSED THAT THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES NEEDED TO BE REPLACED. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE AND STATED THAT THE VEHICLE WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE). THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 130,000 AND THE CURRENT MILEAGE WAS 132,000. *TR

Engine and Engine CoolingFire
Filed Dec 2, 2011176,000 milesKS

I WAS DRIVING TO WORK AND THE ENGINE CAUGHT FIRE. *TR

Fuel System, Gasoline
Filed May 10, 2011110,000 milesTX

THE FUEL TANK STRAPS ON MY 1991 FORD F-150 HAVE RUSTED AND CAUSED MY FUEL TANKS TO LEAK GASOLINE. *TR

Fuel System, Gasoline
Filed Nov 5, 201095,000 milesIN

TL*THE CONTACT OWNS A 1991 FORD F-150. WHILE DRIVING AT AN UNKNOWN SPEED, THE CONTACT NOTICED THAT FUEL WAS LEAKING. THE FAILURE OCCURRED INTERMITTENTLY. THE CONTACT WAS INFORMED BY THE MANUFACTURER THAT THE VEHICLE WAS NOT INCLUDED IN RECALL 01I008000 (FUEL SYSTEM, GASOLINE). THE VEHICLE HAD NOT BEEN REPAIRED. THE FAILURE MILEAGE WAS APPROXIMATELY 95,000 AND THE CURRENT MILEAGE WAS APPROXIMATELY 130,000.

Fuel System, Gasoline
Filed Nov 5, 201089,429 milesMI

TL*THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT WHILE DRIVING LESS THAN 1 MPH, THERE WAS A STRONG FUEL ODOR. THE CONTACT PULLED OVER AND NOTICED THAT FUEL LEAKING FROM THE GAS CAP. THE CONTACT CALLED THE DEALER WHO STATED THAT THEY COULD NOT CHECK THE VIN BECAUSE THE SYSTEM WAS OUTDATED. THE VEHICLE HAD NOT BEEN REPAIRED. THE FAILURE MILEAGE WAS 89,429 AND THE CURRENT MILEAGE WAS 89,430.

Fuel System, Gasoline › Storage › Tank Assembly
Filed Jul 14, 2010122,000 milesNC

TL* THE CONTACT OWNS A 1991 FORD F150. THE CONTACT STATED THE FUEL GAUGE THAT WOULD SWITCH FROM ONE FUEL TANK TO THE OTHER FAILED. HE PREVIOUSLY RECEIVED NOTIFICATION OF NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY) BUT FAILED TO TAKE THE VEHICLE TO THE DEALER FOR REPAIRS. ONCE THE FAILURE OCCURRED, THE CONTACT INQUIRED ABOUT THE RECALL WITH THE DEALER BUT WAS ADVISED THAT THE RECALL HAD EXPIRED. THE DEALER ADVISED THAT ANY REPAIRS WOULD BE AT THE CONTACTS EXPENSE. THE MANUFACTURER WAS NOT CONTACTED. THE FAILURE AND CURRENT MILEAGES WERE 122,000.

Fuel System, Gasoline
Filed Mar 16, 2010170,000 milesIL

TL* THE CONTACT OWNS A 1991 FORD F-150. THE VEHICLE WAS EQUIPPED WITH A DUAL FUEL TANK. THE CONTACT OBSERVED FUEL LEAKAGE IN THE SECOND FUEL TANK SPILLING FUEL INTO THE FIRST FUEL TANK AND CAUSING AN EXCESSIVE OVERFLOW. THERE WERE TWO RECALLS UNDER NHTSA CAMPAIGN ID NUMBERS 01I008000 (FUEL SYSTEM, GASOLINE) AND 93V125000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY). THE VIN WAS EXCLUDED FROM THE SAFETY RECALL. THE VEHICLE HAD NOT BEEN REPAIRED. THE CONTACT HAD CONCERN OF THE POTENTIAL SAFETY HAZARD. THE FAILURE MILEAGE WAS 170,000. THE CURRENT MILEAGE WAS 182,000.

Engine and Engine Cooling
Filed Oct 19, 200989,953 milesOH

TL*THE CONTACT OWNS A 1991 FORD F150 PICKUP TRUCK. HIS VEHICLE EXHIBITS A NO-START CONDITION. HE HAD TO REPLACE THE STARTER AND THE SOLENOID. NONE OF THE REPAIRS HAVE REMEDIED THE FAILURE. THE VEHICLE WAS NOT TAKEN TO THE DEALER DUE TO THE DIAGNOSTIC TESTING FEE. THE FAILURE MILEAGE WAS 89,953.

Fuel System, Gasoline › Storage › Tank Assembly
Filed Nov 13, 2008200,000 milesMO

TL*- THE CONTACT OWNS A 1991 FORD F150 PURCHASED MARCH 2007. THE VEHICLE HAD DUAL FUEL STORAGE TANKS THAT BEGAN LEAKING. THE CONTACT WAS ADVISED THAT FUEL WAS LEAKING FROM THE VEHICLE AND THEN NOTICED THAT IT HAD LEAKED ONTO THE DRIVEWAY. ALTHOUGH THERE WAS A RECALL ON THE VEHICLE NHTSA CAMPAIGN NUMBER 93V125000) THE VIN WAS NOT INCLUDED IN THE RECALL. THE FAILURE AND CURRENT MILEAGES WERE LESS THAN 200,000. UPDATED 12-15-08 *BF GAS FILL UP FRONT TANK FROM THE REAR TANK AND OVER FLOWS OUT OF THE FILLER NECK OF THE FRONT TANK. UPDATED 12/17/08. *JB

Fuel System, Gasoline
Filed Sep 3, 200870,000 milesMN

TL*THE CONTACT OWNS A 1991 FORD F150 4X4 XLT 300. THE VEHICLE HAS DUAL TANKS AND CAN TRAVEL APPROXIMATELY 100 MILES ON ONE TANK. WHEN SWITCHING TO THE OTHER TANK, THE VEHICLE COULD ONLY TRAVEL APPROXIMATELY 20 MILES BEFORE RUNNING OUT OF FUEL. THROUGH RESEARCH, THE CONTACT DISCOVERED THAT THE CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSED A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK WAS EXCEEDED. FORD STATED THAT NHTSA CAMPAIGN ID NUMBER 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY) WAS VOID AND THE CONTACT WOULD BE LIABLE FOR THE RECALL REPAIRS AFTER TEN YEARS. FORD ALSO STATED THAT THE RECALL REPAIRS WERE ALREADY COMPLETED. THE CONTACT STATED THAT IF THE REPAIRS WERE DONE, THE FAILURE WOULD NOT BE PRESENT. THE FAILURE MILEAGE WAS 70,000 AND CURRENT MILEAGE WAS 74,561.

Fuel System, Gasoline
Filed Aug 20, 2008105,000 milesGA

RECALL 93V125000. MY 1991 FORD F150 IS EXPERIENCING THE PROBLEM THIS RECALL ADDRESSED. I CALLED THE FORD 800# AND THEY COULD NOT AND WOULD NOT TELL ME IF MY VEHICLE HAD THIS RECALL PERFORMED ON IT, TO CONTACT A DEALER. I CONTACTED A DEALER WHO SAID THEY COULD NOT TELL ME EITHER. I HAVE OWNED THE VEHICLE ITS ENTIRE LIFE. LOCAL FORD DEALER, GWINNETT PLACE FORD. THIS SAFETY RELATED RECALL INVOLVES SPILLAGE OF GASOLINE ON OUR ROADS/ENVIRONMENTS, MUCH LESS A SAFETY ISSUE CAUSING AN EXPLOSION AND/OR DEATH. I CAN NOT GET ANY HELP FROM FORD CORPORATE OR LOCAL FORD DEALER. *TR

Fuel System, Gasoline
Filed Aug 9, 200769,362 milesNJ

1991 FORD F150 PICK UP WITH FUEL TANK SYSTEMS PROBLEMS. CUSTOMER STATES THAT A RECALL WAS DONE IN 1994 FOR THE FUEL TANK DELIVERY SYSTEM AND NOW IT IS GONE BAD AGAIN AND HE WANTS TO BE REIMBURSED FOR THE REPAIRS DONE**CC *JB

20 of 304 complaints, reproduced as filed.

Across model years

Worst on record: 2013
YearComplaintsRecallsFiresDeathsAssessment
20270100Routine
20268500Routine
20251021320Routine
20241871130Routine
20234071340Above average
20225902370Above average
20211,0092940Do not drive
20207241130Above average
20191,322970Above average
20182,30019333Fatalities reported
20171,43718210High concern
20162,04514250High concern
20151,70714133Fatalities reported
20141,5318161Do not drive
20132,9803354Fatalities reported
20121,7804142Fatalities reported
20112,1886180Above average
20108421350High concern
2009324280Above average
20083691122Fatalities reported
20074887131Fatalities reported
200658514181Fatalities reported
20051,11214292Fatalities reported
20042,02916406Fatalities reported
200342311371Fatalities reported
200282110950High concern
20011,236192487Fatalities reported
20001,074173431Fatalities reported
19991,044186911Fatalities reported
19981,38118911Fatalities reported
19972,7582626214Fatalities reported
19963247752Fatalities reported
199562671142Fatalities reported
1994676131010High concern
199358613211Fatalities reported
19924709395Fatalities reported
1991 — this page3046410High concern
19902755320High concern

Compare every F-150 year →

Reading this record

A high number of complaints describe fires or crashes.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.

Most recent recall on file: Jul 19, 2001. Source: NHTSA Office of Defects Investigation.