2000 Ford E-350

Fatalities reported

Owners filed 59 complaints about this vehicle with federal regulators, most often about the tires. It has been recalled 8 times.

When it fails
020k40k60k90k120k200k
100,566 milesMedian miles at failure

30 complaints record an odometer reading. Failures cluster around 150,000200,000 miles.

What fails
ComponentReportsCrashesFiresInjuries
Tires9
101
Tires › Tread/Belt8
000
Suspension › Front4
000
Fuel System, Diesel4
000
Fuel System, Diesel › Storage › Tank Assembly3
000
Engine and Engine Cooling3
000
Vehicle Speed Control2
010
Engine and Engine Cooling › Engine2
000
Engine2
000
Visibility › Rearview Mirrors/Devices › Exterior1
000

8 safety recalls

Part 573 reports
Vehicle Speed Control09V399000
Filed Oct 13, 20094,500,000 vehiclesFord Motor Company

Defect. FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Risk. A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.

Remedy. FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

Equipment Adaptive/Mobility08V519000
Filed Oct 6, 2008133 vehiclesMobility Works

Defect. MOBILITYWORKS IS RECALLING 133 MY 2005-2006 FORD E250, MY 2000, 2004-2006 E350, MY 2000, 2005 E450, MY 2005-2006 GMC 2500, GMC 3500, AND MY 2006 DODGE 2500 VANS EQUIPPED WITH RICON PLATFORM STYLE WHEELCHAIR LIFTS. THESE LIFTS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 403, "PLATFORM LIFT SYSTEMS FOR MOTOR VEHICLES." THE ANTI-STOW INTERLOCK MAY NOT DETECT THE PRESENCE OF A WHEELCHAIR OR MOBILITY AID USER. THE PRESSURE SENSING SWITCH THAT DETECTS THE PRESENCE OF WEIGHT ON THE PLATFORM WAS NOT ADJUSTED TO THE NECESSARY SENSITIVITY LEVEL. THE LIFT COULD STOW EVEN THOUGH SOMEONE OR SOMETHING IS STILL ON THE LIFT.

Risk. A LIFT OCCUPANT CAN BE INJURED SHOULD THE LIFT BEGIN TO STOW UNINTENTIONALLY.

Remedy. MOBILITYWORKS IS WORKING WITH RICON TO CORRECT THE WHEELCHAIR LIFTS FREE OF CHARGE (PLEASE SEE 07E097). OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR MOBILITYWORKS AT 1-800-769-8267.

Vehicle Speed Control › Cruise Control08V051000
Filed Feb 4, 2008225,000 vehiclesFord Motor Company

Defect. FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Risk. AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy. DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

Vehicle Speed Control07V336000
Filed Aug 3, 20073,600,000 vehiclesFord Motor Company

Defect. ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Risk. THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy. DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

Equipment Adaptive/Mobility04V562000
Filed Nov 26, 20041,660 vehiclesMobility Works

Defect. ON CERTAIN VANS EQUIPPED WITH SURE-LOK WHEELCHAIR SECUREMENT SYSTEMS, THE SPROCKET TEETH OF THE RETRACTOR ASSEMBLY IS OUT OF ALIGNMENT.

Risk. IN THE EVENT OF A VEHICLE CRASH, THE WHEELCHAIR MAY NOT BE ADEQUATELY SECURED POSSIBLY RESULTING IN INJURIES TO A WHEELCHAIR OCCUPANT.

Remedy. DEALERS WILL INSPECT AND REPLACE THE WHEELCHAIR SECUREMENT RETRACTORS AS NECESSARY. SURE-LOK WILL HANDLE THE REPAIRS FOR THIS CAMPAIGN. OWNERS SHOULD CONTACT SURE-LOCK AT 1-908-231-1804 OR MOBILITYWORKS AT 1-800-769-8267.

Fuel System, Gasoline › Storage › Tank Assembly01V114000
Filed Apr 5, 2001151,000 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: ON CERTAIN VANS WITH AMBULANCE PREP PACKAGES OR OTHER SEVERE-DUTY APPLICATIONS INVOLVING OPERATION AT OR NEAR THE GROSS VEHICLE WEIGHT WITH FREQUENT TWISTING OF THE VEHICLE BODY, SUCH AS OFF-ROAD, ROUGH ROAD OR SPEED BUMP EVENTS, THE 35 GALLON MID-SHIP FUEL TANK COULD DEVELOP A CRACK WHERE IT CONTACTS THE FRAME CROSS MEMBER. IF THE FUEL TANK CRACKS, FUEL LEAKAGE COULD OCCUR.

Risk. FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A FIRE.

Remedy. DEALERS WILL INSPECT THE FUEL TANK AND, IF CRACKED, WILL REPLACE THE TANK. INSULATOR PADS WILL BE INSTALLED ON ALL VEHICLES TO REDUCE THE STRESS LEVELS IN THE FUEL TANK. OWNER NOTIFICATION BEGAN APRIL 19, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.

Equipment › Other › Labels00V284000
Filed Sep 21, 20004,500 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: BI-FUEL CNG PICKUP TRUCKS AND BI-FUEL CNG VANS, MODIFIED BY CFI CONTROL SYSTEMS, INC., FAIL TO CONFORM TO THE REQUIREMENTS OF FMVSS NO. 303, "FUEL SYSTEM INTEGRITY OF COMPRESSED NATURAL GAS VEHICLES." THE LABEL AFFIXED TO THE FUEL FILLER DOOR BY THE VEHICLE MODIFIER CONTAINS THE INSPECTION DATE AND EXPIRATION DATE OF THE CNG TANK. HOWEVER, IT DOES NOT CONTAIN THE STATEMENT "SEE INSTRUCTIONS ON THE FUEL CONTAINER FOR INSPECTION AND SERVICE LIFE."

Risk. THESE VEHICLES DO NOT COMPLY WITH THE REQUIREMENTS.

Remedy. OWNERS WILL BE PROVIDED A LABEL WITH THE REQUIRED STATEMENT, ALONG WITH INSTRUCTIONS FOR AFFIXING THE LABEL AT THE FUEL FILLER DOOR. OWNER NOTIFICATION BEGAN NOVEMBER 2, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.

Wheels › Lugs/Nuts/Bolts/Studs00V115000
Filed Apr 19, 20003,300 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: CUTAWAYS AND STRIPPED CHASSIS WITH SINGLE REAR WHEELS. THE LUG NUTS CAN POTENTIALLY BOTTOM OUT ON A SHOULDER ON THE STUDS.

Risk. IF THIS OCCURS, THERE CAN BE AN INADEQUATE CLAMP LOAD TO ATTACH THE WHEEL TO THE AXLE, RESULTING IN NOISE, DAMAGE TO THE WHEEL AND HUB, OR IN EXTREME CASES, LOSS OF A REAR WHEEL WHILE THE VEHICLE IS BEING DRIVEN.

Remedy. DEALERS WILL REPLACE THE REAR WHEEL ATTACHING STUDS.

What owners reported

Newest filings
Service BrakesFire
Filed Mar 13, 2019169,000 milesOH

TL* THE CONTACT OWNS A 2000 FORD E-350. WHILE DRIVING 70 MPH, THE VEHICLE ACCELERATED WITHOUT WARNING. THE BRAKE PEDAL WAS DEPRESSED, BUT THE VEHICLE FAILED TO DECELERATE. THE CONTACT PLACED THE GEAR SHIFTER INTO NEUTRAL TO STOP THE VEHICLE. THE CONTACT COASTED THE VEHICLE OVER TO THE SIDE OF THE ROAD AND POWERED OFF THE ENGINE TWICE. WHEN THE VEHICLE WAS RESTARTED, IT OPERATED NORMALLY AND WAS DRIVEN TO THE CONTACT'S RESIDENCE. IN ADDITION, WHILE DEPRESSING THE BRAKE PEDAL, SMOKE APPEARED FROM THE BRAKE PEDAL. THE VEHICLE WAS NOT TAKEN TO A DEALER OR AN INDEPENDENT MECHANIC FOR DIAGNOSTIC TESTING. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 169,000.

Engine
Filed Nov 30, 2018151,000 milesMI

TL* THE CONTACT OWNS A 2000 FORD E-350. THE CONTACT HEARD A LOUD, BOOMING NOISE FROM THE FRONT OF THE VEHICLE. THE CONTACT DISCOVERED THAT A SPARK PLUG EXPLODED AND DISLODGED FROM THE ENGINE, WHICH SHATTERED THE ENGINE COIL PACK. THE VEHICLE WAS NOT DIAGNOSED OR REPAIRED. THE LOCAL DEALER (TOM HOLZER FORD, 39300 W. 10 MILE RD, FARMINGTON HILLS, MI) WAS NOTIFIED OF THE FAILURE. THE MANUFACTURER WAS NOT NOTIFIED. THE FAILURE MILEAGE WAS 151,000.

Engine
Filed Mar 19, 2015213,723 milesWA

THE SPARK PLUG NO.7 BLOW OUT WITH THE IGNITION COIL. *TR

Vehicle Speed ControlFire
Filed Oct 16, 2014NJ

2000 FORD E-350. CONSUMER WRITES IN REGARDS TO VEHICLE FIRE. *SMD THE CONSUMER STATED THE FIRE DAMAGED HIS HOUSE AND THE VAN WAS DESTROYED. THE CONSUMER BELIEVED THE CRUISE CONTROL WAS THE CAUSE OF THE FIRE. *JB

Tires
Filed Jan 14, 201376,544 milesTX

TL* THE CONTACT OWNS A 2000 FORD E350 EQUIPPED WITH RUNWAY ENDURO HT TIRES, SIZE LT 225-75-R16 DOT NUMBER (5WTM0408). THE CONTACT STATED THAT UPON INSPECTION, IT WAS NOTICED THAT THE TREAD ON THE PASSENGER REAR TIRE WAS EXTREMELY WORN AND NEEDED TO BE REPLACED. THE TIRE WAS REPLACED BEFORE THE STEEL BELTS FAILED. THE MANUFACTURER WAS NOT NOTIFIED. THE TIRE MILEAGE WAS 18,478. THE FAILURE MILEAGE WAS 76,544. ... UPDATED 02/28/13 *BF THE CONSUMER STATED THE TIRE WAS ABNORMALLY WORN IN ONE SPOT. THE CONSUMER IS IN POSSESSION OF THE TIRE. UPDATED 03/27/2013 *JS

Fuel System, Diesel
Filed Aug 15, 2012NY

MY FUEL TANK INTERIOR FLAKED SO SEVERELY IT CAUSED THE ENGINE TO BUCK VIOLENTLY AND DRAMATICALLY LOOSE POWER. THIS WAS CAUSED BY THE ALMOST COMPLETE BLOCKAGE OF THE FUEL TANK PICKUP SCREEN/FILTER. SINCE THAT TIME I HAVE HAD TO DISASSEMBLE AND THOROUGHLY CLEAN THE FUEL PICKUP OF THE FLAKES 4 TIMES INCLUDING TODAY. EACH TIME THE PICKUP WAS PACKED WITH SILVER FLAKES FROM THE DETERIORATING LINING OF THE FUEL TANK. THE PROBLEM OCCURRED EACH TIME WHILE TRAILERING MY RV DOWN THE INTERSTATE. IT IS EXTREMELY SCARY AND THE ALMOST COMPLETE LOSS OF POWER MAKES IT VERY DIFFICULT TO GET TO THE NEXT EXIT. THE PROBLEM IS SO PERSISTENT THAT I HAVE PUT A DOOR IN THE FLOOR OF MY VAN SO THAT I NO LONGER HAVE TO DROP THE TANK FOR ACCESS. I PURCHASED THIS FORD E-350 DIESEL NEW IN 2000. *TR

Fuel System, Diesel
Filed Oct 15, 2010198,000 milesNJ

I WAS DRIVING A FORD DIESEL VAN NORTH ON HIGHWAY 31 TOWARDS PENNINGTON, NJ, WHEN THE TRUCK STARTED ACTING UP. ULTIMATELY, IT STALLED - RIGHT THERE ON THE HIGHWAY; 4 LANES, SEMI TRUCKS COMING AROUND A BEND @ 40 + MPH, AND NO SHOULDER. I TOLD MY HELPER TO LEAVE THE TRUCK BECAUSE I WAS SURE WE WERE GOING TO GET HIT. NO WAY A TRACTOR TRAILER, AT THOSE SPEEDS, COULD STOP IN TIME. SEVERAL SEMI'S HAD TO CUT OFF CARS IN THE LEFT LANE TO AVOID US. I THOUGHT FOR SURE I WAS DEAD. AFTER SWEATING IT OUT, I FINALLY GOT THE TRUCK STARTED AND GOT TO A SIDE STREET, AT ABOUT 5 MPH. THAT'S WHEN I CALLED AAA & GOT THE TRUCK TOWED TO MY FORD DEALER, WHERE THEY WANT $2500 TO REPAIR WHAT THEY CALL " FUEL TANK DELAMINATION". I NEVER HEARD OF SUCH A THING AND NEITHER DID ANYONE I SPOKE WITH IN THE AUTO REPAIR INDUSTRY SO I GOOGLED IT: FORD DIESEL FUEL TANK PROBLEMS, AND AS IT TURNS OUT, THERE ARE THOUSANDS OF VEHICLES OUT THERE WITH THE EXACT SAME PROBLEM. I"M SURPRISED NO ONE HAS DIED YET, BUT I GUESS THAT'S WHAT IT WILL TAKE, MAYBE WHEN A COUPLE OF KIDS DIE, FORD WILL DO SOMETHING ABOUT IT, IF IT DOESN'T COST TOO MUCH - OF COURSE. TO ALLEVIATE THIS "PROBLEM," THE FORD DEALER IS, IN EFFECT, GOING TO REPLACE THE ENTIRE FUEL DELIVERY SYSTEM, AT THE CONSUMERS COST. NEW FUEL TANK, NEW FUEL TRANSFER PUMP, CLEAN OUT THE FUEL LINES, REPLACE FUEL FILTER, CLEAN INJECTORS, SO, BEND OVER. PS REALLY HOPE NOBODY HAS TO DIE - BUT THAT'S YOUR CALL. *TR

Engine and Engine Cooling
Filed Jul 4, 2010NJ

2000 FORD V8 TRITON ENGINE SPARK PLUG POPPED OUT AND ENGINE MISFIRE HAD THE COIL REPLACED AND HAD MECHANIC TAP OUT THE SPARK PLUG HOLE AND RE SET THE PLUG AND THEN IT HAPPENED AGAIN ON SATURDAY JULY 3RD 2010. *TR

Fuel System, Diesel
Filed Jun 1, 2010140,000 milesWA

FORD E350 7.3 LITER DIESEL VAN - HAVING INTERMITTENT PROBLEMS WITH POWER AND BOGGING DOWN AND AT TIMES DYING. DROPPED THE FUEL TANK AND FOND PAINT FLAKES FROM THE TANK DELAMINATING. HAVING TO REPLACE THE TANK AND HOPING THERE IS NO FURTHER DAMAGE ALREADY DONE. *TR

Fuel System, Other
Filed Feb 3, 2010183,900 milesWA

I HAVE A 2000 FORD E350 THAT STARTED RUNNING ROUGH AND EVENTUALLY LOST POWER ON THE FREEWAY WHEN IT WAS NEEDED I DID'NT KNOW WHAT HAPPENING TO THE VEHICLE IT JUST STARTED SPUTTERING AND SPEWING THICK SMOKE OUT OF THE TAIL PIPE. I LIMPED THE VAN TO THE DEALETSHIP AND AFTER ALL DIAGNOSIS AND REPLACEMENT OF CERTAIN FUEL PARTS WAS SAID AND DONE IT WAS A CLOGGED FUEL SENDING UNIT DUE TO A RUSTY FUEL TANK CAUSED BY DELAMINATION OF THE LINING INSIDE THE TANK. THESE PARTICALS OF DELAMINATION AND THE RUST OF THE EXPOSED METAL OF THE TANK CAUSED THE SENDING UNIT TO BE CLOGGED TO THE POINT OF REPLACEMENT, THE SENDING UNIT ALONE WAS OVER $600.00 OF THE $1600.00 BILL, IT WAS EXPLAINED TO ME THAT THE PROBLEM OF THE CLOGGED FUEL SENDING UNIT WILL HAPPENING AGAIN IN ABOUT A YEAR DUE TO THE TANK FAILING. I AM VERY CONCERNED WITH LOSING POWER AGAIN AND NOT BEING ABLE TO GET OFF THE ROAD ON A MAJOR FREEWAY AND SPEWING THE BIG CLOUD SMOKE OUT THE TAIL PIPE WHEN THIS HAPPENS AGAIN AND POSSIBLY BLINDING THE DRIVERS BEHIND ME. I SPOKE WITH THE DEALER, I WAS ADVISED THAT THE TANKS ARE MADE OF PLASTIC NOW TO AVOID/FIX THIS PROBLEM. I SPOKE WITH FORD MOTOR CORP., THEY STATED THAT MY VEHICLE WAS OUT OF WARRANY AND THEY WOULD NOT COVER THIS UNVOIDABLE PROBLEM. I HAVE TAKEN VERY GOOD CARE OF THIS VEHICLE, IT IS A SERVICE VEHICLE FOR MY COMPANY AND WHEN IT IS DOWN I DO NOT MAKE ANY MONEY. I DO EVERYTHING I CAN TO PERFORM THE PREVENITIVE MAINTENANCE, THERE IS NOTHING I COULD HAVE DONE TO AVOID THIS SAFETY

Vehicle Speed Control › Cruise Control
Filed Nov 3, 2009203,304 milesNY

TL* THE CONTACT OWNS A 2000 FORD E-350. HE RECEIVED RECALL NOTICE # 08V051000 (VEHICLE SPEED CONTROL:CRUISE CONTROL). THE VEHICLE WAS NOT REPAIRED SINCE AN AUTHORIED TECHNICIAN COULD NOT PROVIDE AN ESTIMATE ON WHEN THE PARTS WOULD BE AVAILABLE. THE FAILURE MILEAGE 203,304

Electrical System
Filed May 22, 2008LA

TL*THE CONTACT OWNS A 2000 FORD E-350. THE CONTACT RECEIVED A RECALL NOTICE IN AUGUST OF 2007 FOR THE ELECTRICAL SYSTEM. THE VEHICLE WAS TAKEN TO A LOCAL AUTHORIZED DEALER FOR REPAIR IN NOVEMBER OF 2007, BUT THE MECHANIC STATED THAT THERE WAS NO RECALL REPLACEMENT PART AVAILABLE. THE CONTACT WAS CONSISTENTLY CALLING THE DEALER TO SEE IF THE PART HAD ARRIVED, BUT WAS INFORMED AGAIN THAT THE PART HAD NOT BEEN MANUFACTURED AND TO CALL BACK LATER. THE CONTACT HAS BECOME VERY DISCOURAGED AND DOES NOT KNOW IF THE RECALL PART WILL EVER BE MANUFACTURED BY FORD. HE WAS UNDER THE ASSUMPTION THAT ALL THE VEHICLES INCLUDED IN THE RECALL NEEDED THE PART TO WARRANT THE REPAIR SERVICE. THERE HAD BEEN NO FAILURE TO DATE. UPDATED 6/16/08 *CN

Engine and Engine Cooling › Engine
Filed Apr 14, 2008183,000 milesMT

SECOND TIME SPARK PLUG HAS BLOWN OUT OF THE HEAD, ONCE EACH SIDE. $3500 REPAIR FIRST TIME. WE'LL SEE ON THIS ONE. *TR

Vehicle Speed Control
Filed Apr 1, 2008OR

TL*THE CONTACT OWNS A 2000 FORD E-350. THE CONTACT RECEIVED A RECALL NOTICE FOR THE VEHICLE SPEED CONTROL. SHE TOOK THE VEHICLE TO THE DEALER IN AUGUST OF 2007 AND THE CRUISE CONTROL WAS DEACTIVATED. SINCE THAT TIME, SHE HAS BEEN WAITING FOR THE RECALL REPAIR TO BE PERFORMED; HOWEVER, SHE HAS BEEN GIVEN FOUR DIFFERENT DATES AS TO WHEN THE PART WOULD BE AVAILABLE. THERE HAD BEEN NO FAILURE TO DATE. THE CURRENT MILEAGE WAS 42,000. UPDATED 4/21/08 *CN

Electrical System › Wiring
Filed Feb 25, 2008MS

FORD HAS A RECALL #08S01 ON THEIR FUSED JUMPER HARNESS .WE ARE A CHURCH WITH TWO VEHICLES THAT ARE NEEDING THIS RECALL. THE LOCAL DEALER METRO FORD IN TUPELO MISSISSIPPI HAS NOT HAD THIS PART FOR THREE MONTHS AND HAS NOT IDEA WHEN IT WILL COME INTO THEIR SHOP. DO YOU HAVE ANY INFORMATION ON THIS SUBJECT. CAN YOU HELP ME WITH ISSUE? PAUL *TR

Fuel System, Diesel › Storage › Tank Assembly
Filed Feb 8, 200865,936 milesHI

7.3 LITER DIESEL ENGINE STALLING. FUEL PUMP AND FUEL FILTER REPLACED;FUEL TANK REMOVED AND CLEANED; SILVER PAINT FLAKES WERE FOUND BLOCKING THE FUEL PICKUP. TANK WAS RE-INSTALLED AND PROBLEM RE-OCCURRED WITHIN 100 MILES. VAN WAS TAKEN TO LOCAL FORD DEALERSHIP AND TANK WAS REMOVED AGAIN. SILVER PAINT FLAKES WERE FOUND BLOCKING THE FUEL PICKUP LINE AGAIN. THE SERVICE TECHNICIAN DETERMINED THAT THE FUEL TANK LINER WAS DE-LAMINATING, AND THE FUEL TANK NEEDED REPLACING. I HAVE THE DEFECTIVE TANK IN MY POSSESSION. THIS WAS A DANGEROUS DEFECT THAT CAUSED ENGINE STALLING IN HEAVY TRAFFIC, ENDANGERING MYSELF AND OTHER MOTORISTS BEHIND AND BESIDE ME. THIS WAS ALSO AN EXPENSIVE AND TIME CONSUMING REPAIR, RESULTING IN LOSS OF USE AND RENTAL EXPENSES. *TR

Engine and Engine Cooling
Filed Oct 31, 2007179,525 milesCA

I HAVE A 200 FORD E-350. AT 130,000 MILES THE SPARK PLUG BLEW OUT OF NUMBER 8 CYLINDER. AND BROKE THE COIL PACK. THEN BLEW OUT AGAIN AT 155,000 MILE AND NOW HAS TAKEN THE THREADS WITH IT. THE ENGINE MUST BE PULLED, IN WHICH WILL RESULT IN A HUGE BILL FOR ME. FORD SHOULD BE MADE TO RECALL THIS PROBLEM THEY HAVE WITH MANY OF THERE ENGINES. *TR

Power Train › Automatic Transmission › Lever and Linkage › Column ShiftCrash
Filed Sep 26, 2007131,000 milesIL

PARKED TRUCK IN MY DRIVEWAY,WENT IN TO EAT LUNCH,CAME OUT FOUND TRUCK ROLLED DOWN DRIVEWAY,CROSSED THE ROAD ON TO MY NEIGHBORS LAWN WHERE IT HIT A TREE AND DID EXTENSIVE DAMAGE TO FRONT OF TRUCK. *JB

Fuel System, Diesel › Storage › Tank Assembly
Filed May 25, 200799,000 milesIN

2000 FORD E-350 ECONOLINE DIESEL SERIAL [XXX] WAS SUBJECT TO RECALL DUE TO LEAKING DIESEL FUEL FROM 35 GAL. TANK. FORD CLAIMS RECALL WAS PERFORMED FOR PREVIOUS OWNER. TANK IS LEAKING AGAIN. REPAIR WAS NOT SUFFECIENT TO ELIMIATE FAILURE. MILEAGE AT SECOND LEAKAGE 99,000 TO PRESENT. *JS INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6)

Engine and Engine Cooling › Engine › Gasoline
Filed Feb 11, 2007128,468 milesMI

2000-FORD E-350 SPARK PLUG BLEW RIGHT OUT OF THE ALUMINUM HEAD. *NM

20 of 59 complaints, reproduced as filed.

Across model years

Worst on record: 1997
YearComplaintsRecallsFiresDeathsAssessment
20270100Routine
20260100Routine
20252100Routine
20242100Routine
20232200Routine
202214300Routine
202122600Routine
20202000Routine
20193010Routine
20183400Routine
201713410Routine
20165300Routine
20157200Routine
2014171110Routine
201313900Routine
2012161210Routine
2011192000Routine
2010171800Routine
2009102720Routine
2008393200Routine
2007183510Routine
2006533920Routine
2005551620Routine
2004461111Fatalities reported
200346841Fatalities reported
200253510Routine
200152430Routine
2000 — this page59832Fatalities reported
199972932Fatalities reported
199863810Routine
199779562Fatalities reported
199650310Routine
199569331Fatalities reported
199451550Routine
199343340Routine
199241340Routine
199119120Routine
199023210Routine

Compare every E-350 year →

Reading this record

2 deaths reported in complaints filed with NHTSA.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.

Most recent recall on file: Oct 13, 2009. Source: NHTSA Office of Defects Investigation.