Owners filed 63 complaints about this vehicle with federal regulators, most often about the tires. It has been recalled 8 times.
What fails
Component
Reports
Crashes
Fires
Injuries
Tires
9
0
0
0
Service Brakes, Hydraulic › Antilock/Traction Control/Electronic Limited Slip
5
0
0
0
Tires › Tread/Belt
4
0
0
0
Fuel System, Other › Storage › Tank Assembly
4
0
0
0
Engine and Engine Cooling
4
0
0
0
Vehicle Speed Control
2
0
1
0
Suspension
2
0
0
0
Steering › Gear Box (other Than Rack and Pinion)
2
0
0
0
Service Brakes, Hydraulic
2
1
0
0
Fuel System, Diesel
2
0
0
0
8 safety recalls
Part 573 reports
Equipment Adaptive/Mobility14V197000
Filed Apr 16, 201466 vehiclesCummings Mobility Conversion & Supply, I
Defect. Cummings Mobility Conversion & Supply, Inc. (Cummings) is recalling various model year 1994-2011 Ford and Chevrolet vans equipped with Braun NCL-2, and NVL-2 wheel chair lifts manufactured November 20, 2006, through September 10, 2010. Over time, and with frequent use, the roll stop latches on the outer barrier of the lifts in these vans may become bent or misaligned.
Risk. A wheelchair occupant may defeat or ride over the insufficiently latched roll stop. If this occurs when the lift platform is in an elevated position, the wheelchair's occupant could fall and sustain injury.
Remedy. Braun Corporation notified all the vehicle owners, and Cummings Mobility replaced the recalled parts with new parts, free of charge. The recall was completed as of April 10, 2014. Owners may contact Cummings customer service at 1-800-639-5438.
Vehicle Speed Control09V399000
Filed Oct 13, 20094,500,000 vehiclesFord Motor Company
Defect. FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Risk. A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.
Remedy. FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Equipment Adaptive/Mobility09V014000
Filed Jan 14, 200919 vehiclesOneness Mobility Services, Llc
Defect. ONENESS MOBILITY IS RECALLING 19 MY 1998, AND 2005-2006 E-350 VANS BUILT ON FORD CHASSIS AND EQUIPPED WITH RICON PLATFORM STYLE WHEELCHAIR LIFTS. THESE LIFTS FAIL TO COMPLY WITH THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 403, "PLATFORM LIFT SYSTEM ACCESSIBLE FOR MOTOR VEHICLES." THE ANTI-STOW INTERLOCK MAY NOT DETECT THE PRESENCE OF A WHEELCHAIR OR MOBILITY AID USER. THE PRESSURE SENSING SWITCH THAT DETECTS THE PRESENCE OF WEIGHT ON THE PLATFORM WAS NOT ADJUSTED TO THE NECESSARY SENSITIVITY LEVEL. THE LIFT COULD STOW EVEN THOUGH SOMEONE OR SOMETHING IS STILL ON THE LIFT.
Risk. A LIFT OCCUPANT CAN BE INJURED SHOULD THE LIFT BEGIN TO STOW UNINTENTIONALLY.
Remedy. ONENESS MOBILITY IS WORKING WITH RICON TO CORRECT THE WHEELCHAIR LIFTS FREE OF CHARGE (PLEASE SEE 07E097). OWNERS MAY CONTACT RICON AT 1-818-267-3000 OR ONENESS MOBILITY AT 1-818-267-3000.
Vehicle Speed Control › Cruise Control08V051000
Filed Feb 4, 2008225,000 vehiclesFord Motor Company
Defect. FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Risk. AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy. DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
Vehicle Speed Control07V336000
Filed Aug 3, 20073,600,000 vehiclesFord Motor Company
Defect. ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Risk. THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy. DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Equipment Adaptive/Mobility04V562000
Filed Nov 26, 20041,660 vehiclesMobility Works
Defect. ON CERTAIN VANS EQUIPPED WITH SURE-LOK WHEELCHAIR SECUREMENT SYSTEMS, THE SPROCKET TEETH OF THE RETRACTOR ASSEMBLY IS OUT OF ALIGNMENT.
Risk. IN THE EVENT OF A VEHICLE CRASH, THE WHEELCHAIR MAY NOT BE ADEQUATELY SECURED POSSIBLY RESULTING IN INJURIES TO A WHEELCHAIR OCCUPANT.
Remedy. DEALERS WILL INSPECT AND REPLACE THE WHEELCHAIR SECUREMENT RETRACTORS AS NECESSARY. SURE-LOK WILL HANDLE THE REPAIRS FOR THIS CAMPAIGN. OWNERS SHOULD CONTACT SURE-LOCK AT 1-908-231-1804 OR MOBILITYWORKS AT 1-800-769-8267.
Fuel System, Gasoline › Storage › Tank Assembly01V114000
Filed Apr 5, 2001151,000 vehiclesFord Motor Company
Defect. VEHICLE DESCRIPTION: ON CERTAIN VANS WITH AMBULANCE PREP PACKAGES OR OTHER SEVERE-DUTY APPLICATIONS INVOLVING OPERATION AT OR NEAR THE GROSS VEHICLE WEIGHT WITH FREQUENT TWISTING OF THE VEHICLE BODY, SUCH AS OFF-ROAD, ROUGH ROAD OR SPEED BUMP EVENTS, THE 35 GALLON MID-SHIP FUEL TANK COULD DEVELOP A CRACK WHERE IT CONTACTS THE FRAME CROSS MEMBER. IF THE FUEL TANK CRACKS, FUEL LEAKAGE COULD OCCUR.
Risk. FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A FIRE.
Remedy. DEALERS WILL INSPECT THE FUEL TANK AND, IF CRACKED, WILL REPLACE THE TANK. INSULATOR PADS WILL BE INSTALLED ON ALL VEHICLES TO REDUCE THE STRESS LEVELS IN THE FUEL TANK. OWNER NOTIFICATION BEGAN APRIL 19, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.
Equipment › Other › Labels00V284000
Filed Sep 21, 20004,500 vehiclesFord Motor Company
Defect. VEHICLE DESCRIPTION: BI-FUEL CNG PICKUP TRUCKS AND BI-FUEL CNG VANS, MODIFIED BY CFI CONTROL SYSTEMS, INC., FAIL TO CONFORM TO THE REQUIREMENTS OF FMVSS NO. 303, "FUEL SYSTEM INTEGRITY OF COMPRESSED NATURAL GAS VEHICLES." THE LABEL AFFIXED TO THE FUEL FILLER DOOR BY THE VEHICLE MODIFIER CONTAINS THE INSPECTION DATE AND EXPIRATION DATE OF THE CNG TANK. HOWEVER, IT DOES NOT CONTAIN THE STATEMENT "SEE INSTRUCTIONS ON THE FUEL CONTAINER FOR INSPECTION AND SERVICE LIFE."
Risk. THESE VEHICLES DO NOT COMPLY WITH THE REQUIREMENTS.
Remedy. OWNERS WILL BE PROVIDED A LABEL WITH THE REQUIRED STATEMENT, ALONG WITH INSTRUCTIONS FOR AFFIXING THE LABEL AT THE FUEL FILLER DOOR. OWNER NOTIFICATION BEGAN NOVEMBER 2, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.
What owners reported
Newest filings
Service BrakesCrash
Filed Aug 13, 2022VA
When braking hard, braking power declines after mid peddle range, resulting in crash. Had taken to dealer many years earlier for ABS recall fix.
Engine
Filed Jan 23, 202024,631 milesCA
SPARK PLUGS POTENTIALLY EJECT FROM CYLINDER HEADS DUE TO BAD ENGINEERING DESIGN USING ALUMINUM HEADS WITH INSUFFICIENT AMOUNT OF THREADS TO HOLD SPARK PLUGS WHEN IN MOTION. NEWER VEHICLES WERE RE-ENGINEERED TO ELIMINATE THIS HAPPENING. REQUEST RECALL AND REPAIR.
Tires › Sidewall
Filed Oct 15, 2018130,000 milesIL
TL* THE CONTACT OWNS A 1998 FORD E-350 EQUIPPED WITH STARFIRE SF-510 TIRES, SIZE LT245-75-R16 (NA). WHILE THE VEHICLE WAS AT AN INDEPENDENT MECHANIC FOR A STATE INSPECTION, THE SIDEWALL OF THE REAR DRIVER'S SIDE TIRE WAS FOUND WITH INTERNAL INDENTATIONS. THE MECHANIC STATED THAT THE TIRE NEEDED TO BE REPLACED. THE TIRE WAS NOT REPLACED. THE DEALER AND MANUFACTURER WERE NOT CONTACTED. THE DOT NUMBER WAS UNKNOWN. THE TIRE AND VEHICLE FAILURE MILEAGE WAS 130,000.
Vehicle Speed ControlFire
Filed Jan 27, 2014200,000 milesNY
TL* THE CONTACT OWNS A 1998 FOR E-350. THE CONTACT STATED THAT THE VAN WAS IDLE WHEN HE NOTICED SMOKE COMING FROM THE INSTRUMENT PANEL AND VENTS. THE VEHICLE BECAME ENGULFED IN FLAMES. THE FIRE DEPARTMENT EXTINGUISHED THE FLAMES. A FIRE REPORT WAS NOT FILED. THE MANUFACTURER WAS NOT CONTACTED. THE FAILURE MILEAGE WAS 200,000.
Structure › Body › Door
Filed Jun 24, 2012113,614 milesSC
I RECENTLY HAD A PROBLEM AND STILL HAVE WITH THE PASSENGER SIDE REAR DOOR OF NOT BEING ABLE TO OPEN IT. I GOT OUT OF THE MY FORD VAN AND WENT AROUND TO THE SIDE DOOR TO OPEN IT UP TO GET MY DOGS OUT OF IT. I COULD NOT OPEN THE SIDE DOOR, I THOUGHT THE DOORS HAD SOMEHOW GOT LOCKED AND I WAS PANICING. IT WAS VERY HOT AND I KNEW I HAD TO GET MY DOGS OUT FAST. I WAS HUNTING FOR SOMETHING TO BREAK THE WINDOW OUT WITH BUT HAD NO LUCK FINDING ANYTHING. AFTER ABOUT 20 OR SO MINUTES I FINALLY NOTICED THAT THE FRONT DOOR LOCKS WERE IN THE UP POSITION INDICATING THAT THE DOORS WERE NOT LOCKED. I WAS ABLE TO OPEN THE FRONT DOOR SAVING ME FROM HAVING TOO BREAK OUT THE GLASS AND THEN I WAS ABLE TO GET INTO THE VAN AND OPEN THE REAR DOOR. I LOVE MY DOGS BUT WHAT IF THIS HAD BEEN A CHILD.AND COULDN'T OPEN THE DOORS IN TIME. LUCKLY I DISCOVERED THAT THE FRONT DOORS WERE NOT LOCKED AND THAT IT WAS A MALFUNCTION OF THE BACK DOOR MAKING IT IMPOSSIBLE TO OPEN THAT DOOR. THE RESULTS COULD HAVE BEEN DISTRASTROUS AND NOT TO MENTION THE COST OF REPAIRING THE WINDOW HAD I BEEN ABLE TO BREAK IT, THINGS TURNED OUT WELL THANK GOODNESS BUT IF IT SHOULD HAPPEN TO SOMEONE ELSE THE RESULTS COULD BE VERY DIFFERENT. THIS IS SUNDAY AND I NOW HAVE TO GET MY VAN TO A FORD DEALER TO FIX THE REAR DOOR SO I CAN OPEN IT UP AS I STILL CAN'T OPEN IT UP FROM THE OUTSIDE.. I THINK THE IS A SERIOUS SAFETY PROBLEM THAT SHOULD BE ADDRESSED. *TR
Fuel System, Diesel
Filed Mar 23, 2011198,910 milesNJ
TL*THE CONTACT OWNS A 1998 FORD E-350. WHILE DRIVING THE CONTACT EXPERIENCED A LOSS OF POWER AND THE ENGINE WOULD BEGAN TO MALFUNCTION. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER WHO CONFIRMED THAT THE FUEL SYSTEM WAS DELAMINATING. THE VEHICLE WAS REPAIRED. THE FAILURE MILEAGE WAS 198,910 AND THE CURRENT MILEAGE WAS 202,300.
Electrical System
Filed Mar 3, 2011411,637 milesCA
1998 FORD E 350 POWERSTROKE 7.3 DIESEL. THE CAMSHAFT POSITIONING SENSOR (CPS) FAILURE IS A SERIOUS PROBLEM THAT FORD WILL HAVE TO DEAL WITH. I HAVE HAD THREE INSTANCES OF THE UNIT FAILING ON ME SINCE THIS FIRST ONE ON DEC 13TH, 2007. IN THE FIRST CASE, I WAS TAKING MY SON TO SCHOOL. THE VAN WAS SPUTTERING THE WHOLE WAY AND I EVENTUALLY HAD TO HAVE IT TOWED TO A REPAIR SHOP AFTER A COMPLETE ENGINE FAILURE. FORD HAD JUST ISSUED THE RECALL ON DEC 6TH, 2007, AND THEY HONORED THE REPAIR. THE SECOND CPS INCIDENT HAPPENED ON FEB 23RD, 2010. THE VEHICLE WOULD NOT START; I HAD IT TOWED TO A REPAIR SHOP AFTER GETTING A PARKING TICKET. I CANNOT FIND PROOF THAT FORD HONORED THE REPAIR. THE 3RD CPS INCIDENT HAPPENED ON SUNDAY FEB 27TH, 2011, ONE YEAR AFTER THE 2ND INCIDENT. I WAS IN FLAGSTAFF, AZ DURING A SNOWSTORM, AND THE VEHICLE WAS FAILING ON ME ON ROUTE 66. IT STALLED TWICE ON THE MAIN HIGHWAY AS THE SNOWPLOWS WHIPPED AROUND ME. I GOT BACK TO WHERE I WAS STAYING, AND WAITED UNTIL MONDAY MORNING WHEN I HAD IT TOWED TO A REPAIR SHOP AND HAD THE CPS UNIT REPLACED. THIS ENGINE IS UNSAFE AND UNRELIABLE. THE CPS UNIT CAN FAIL AT ANYTIME, ANYWHERE, AND MAYBE AT ANY SPEED, THOUGH MY ISSUES WERE AT LOW SPEED OR AT STARTUP. FORD WILL NOT HONOR THIS LATEST INCIDENT BECAUSE THEY SAY AFTER MY FIRST REPLACEMENT IN DEC 2007 THAT MY 'CASE WAS CLOSED'. *TR
Engine and Engine Cooling
Filed Mar 3, 2011411,637 milesCA
POWERSTROKE 7.3 DIESEL. THE CAMSHAFT POSITIONING SENSOR (CPS) FAILURE IS A SERIOUS PROBLEM THAT FORD WILL HAVE TO DEAL WITH. I HAVE HAD THREE INSTANCES OF THE UNIT FAILING ON ME SINCE THIS FIRST ONE ON DEC 13TH, 2007. IN THE FIRST CASE, I WAS TAKING MY SON TO SCHOOL. THE VAN WAS SPUTTERING THE WHOLE WAY AND I EVENTUALLY HAD TO HAVE IT TOWED TO A REPAIR SHOP AFTER A COMPLETE ENGINE FAILURE. FORD HAD JUST ISSUED THE RECALL ON DEC 6TH, 2007, AND THEY HONORED THE REPAIR. THE SECOND CPS INCIDENT HAPPENED ON FEB 23RD, 2010. THE VEHICLE WOULD NOT START; I HAD IT TOWED TO A REPAIR SHOP AFTER GETTING A PARKING TICKET. I CANNOT FIND PROOF THAT FORD HONORED THE REPAIR. THE 3RD CPS INCIDENT HAPPENED ON SUNDAY FEB 27TH, 2011, ONE YEAR AFTER THE 2ND INCIDENT. I WAS IN FLAGSTAFF, AZ DURING A SNOWSTORM, AND THE VEHICLE WAS FAILING ON ME ON ROUTE 66. IT STALLED TWICE ON THE MAIN HIGHWAY AS THE SNOWPLOWS WHIPPED AROUND ME. I GOT BACK TO WHERE I WAS STAYING, AND WAITED UNTIL MONDAY MORNING WHEN I HAD IT TOWED TO A REPAIR SHOP AND HAD THE CPS UNIT REPLACED. THIS ENGINE IS UNSAFE AND UNRELIABLE. THE CPS UNIT CAN FAIL AT ANYTIME, ANYWHERE, AND MAYBE AT ANY SPEED, THOUGH MY ISSUES WERE AT LOW SPEED OR AT STARTUP. FORD WILL NOT HONOR THIS LATEST INCIDENT BECAUSE THEY SAY AFTER MY FIRST REPLACEMENT IN DEC 2007 THAT MY "CASE WAS CLOSED IN 2007".
Service Brakes, Hydraulic
Filed Aug 6, 201056,505 milesNC
BRAKE LINE CORROSION THAT LET FLUID DRAIN AND CAUSED BRAKE FAILURE. *TR
Tires
Filed Nov 5, 20098,000 milesFL
I PURCHASED A TOTAL OF 7 MICHELIN LTX M/S TIRES LT225/75R16 E FOR MY MINI MOTORHOME. THEY ARE DRY-ROTTING RIGHT OFF THE RIMS. THIS IS AN ESTABLISHED PROBLEM. WHEN I WAS DIRECTED TO A DEALER (FORREST TIRE OF ARTESIA, NM) I WAS OFFERED A DISCOUNT ON BUYING MORE TIRES. I WAS EXTREMELY DISMAYED THAT MICHELIN WAS QUERYING THE TIRE DEALER ABOUT THE MAKE, MODEL, YEAR AND MILEAGE OF MY MOTORHOME! WHAT HAS THAT GOT TO DO WITH DEFECTIVE/DANGEROUS TIRES? I SPOKE WITH A MAN WHO HAD THE SAME PROBLEM WITH LTX M/S TIRES THAT CAME ON HIS NEW PICKUP AND THEY WERE REPLACED FOR MOUNTING AND BALANCING ONLY. I PURCHASED TWO FOR THE FRONT, BUT SIMPLY CAN'T BUY ALL 7 ON SOCIAL SECURITY, THEN SUE MICHELIN. THESE ARE LOT NUMBERS B3JH FBXX 0905, 0205, AND 4204. I CAN SCRAPE DRIED RUBBER OFF THE SIDEWALL WITH MY FINGERNAIL! THIS IS DANGEROUS, AND I AM SITTING HERE AFRAID TO DRIVE ON THE HIGHWAY, WAITING FOR SOMETHING TO HAPPEN. *TR
Engine and Engine Cooling › Engine
Filed Dec 23, 2008110,000 milesCA
BLOWN SPARK PLUG THREADS. REPAIRED BY SELF USING TIMESERT REPAIR KIT MANUFACTURED SPECIFICALLY FOR THIS ENGINE AND PROBLEM. *TR
Fuel System, Diesel
Filed Dec 9, 2008276,100 milesFL
FUEL TANK LINING DETERIORATING. I HAVE FOUND FLAKES IN MY LAST FOUR FUEL FILTERS. VEHICLE LOSS OF POWER, THEN ROUGH RUNNING. THE FLAKES ARE IN THE FILTER I HAVE ADDED BETWEEN TANK AND FUEL PUMP. THEY ARE SMALL PIECES OF GREY OR SILVER PAINT. I AM GOING TO HAVE TO REPLACE FUEL TANK IN ORDER TO RECTIFY THE PROBLEM. I REPLACED THE FILTER THIS MORNING, PUT APPROX. 90 MILES ON VAN AND FOUND SEVERAL OUNCES IN THE FILTER THIS EVENING. *TR
Tires
Filed Aug 2, 2008FL
SEVERE CRACKING OF SIDEWALLS OF MOTORHOME TIRES THAT ARE ONLY 3 YEARS OLD. CRACKING BEGAN IN LESS THAN ONE YEAR. *TR
Engine and Engine Cooling
Filed May 10, 2008288,849 milesSD
E-350 WITH 68,000 MILES #1 SPARKPLUG BLOWOUT FROM CYLINDER HEAD MARCH 2002 SAME MOTOR WITH 183,000 #7 SPARKPLUG BLOWOUT FROM CYLINDER HEAD SAME MOTOR WITH 288,849 #3 SPARKPLUG BLOWOUT FROM CYLINDER HEAD. *TR
Electrical System › Wiring › Front Underhood
Filed Mar 3, 200825,760 milesAL
I BELIEVE THE EVENTS LEADING TO THE FAILURE IN MY MOTOR HOME STARTED WITH THE FIRST RECALL (SEPT. 2007)THAT SAID THAT A FUSE-ABLE LINK HAD TO BE INSTALLED IN THE BRAKE SYSTEM TO PREVENT A POSSIBLE FIRE HAZARD. I COMPLIED. SHORTLY THERE AFTER MY ABS LIGHT STARTED BLINKING ON AND OFF IRREGULARLY. THEN AFTER A VERY FEW MILES IT STAYED ON ALL THE TIME THE ENGINE WAS RUNNING. I CALLED THE DEALER WHERE THE RECALL WAS PERFORMED AND THEY SAID THAT THE ABS HAD NOTHING TO DO WITH THE RECALL ISSUE . THAT MY BRAKES WOULD STILL WORK, THAT THE ABS JUST EFFECTS THE NONE SKID PREVENTION IN SLIPPERY CONDITIONS. WE TOOK THE MOTOR HOME ON A TRIP TO BIRMINGHAM, (ABOUT 100 MILES) DURING THE THANKSGIVING HOLIDAY. ON 11-24-07 WHILE LEAVING THE CAMPGROUNDS AT ABOUT 20 MPH THE ENGINE QUIT LIKE YOU TURNED OFF THE KEY. A MINOR INSPECTION INDICATED THE MAIN POWER FUSE TO THE COMPUTER HAD BLOWN. . I HAD A WRECKER TOW THE MOTOR HOME TO A DEALERSHIP. THE FOLLOWING MONDAY MORNING I CONTACTED THE SERVICE CENTER AND TOLD THEM WHAT HAD HAPPENED, THEY CHECKED IT OUT AND CALLED ME AND SAID THAT A VERY EXPENSIVE WIRING HARNESS HAD WAS SHORTED OUT BY A O2 SENSOR AND IT WOULD COST AROUND $1750.00 TO FIX IT. I SAID OK, FIX IT. AFTER THE REPAIRS WERE DONE I BROUGHT IT HOME AND HAVEN'T USED IT SENSE. IN FEBRUARY 2008 I GOT ANOTHER RECALL NOTICE THAT THE PART THEY PUT IN MY MOTOR HOME IN THE PREVIOUS RECALL WAS NOT COMPATIBLE WITH MY SYSTEM AND COULD CAUSE A FIRE AT ANY TIME AND IT WAS IMPORTANT THAT IT BE CHANGED AS S
Engine and Engine Cooling
Filed Nov 23, 200598,000 milesNV
ORIGINAL OWNER OF 1998 FORD E350 EXTENDED-LENGTH XLT. AT THE TIME OF THE INCIDENT, THE CAR HAD ABOUT 98,000 MILES. I WAS AT A STOP LIGHT, THE LIGHT TURNED GREEN AND I PROCEEDED THROUGH THE INTERSECTION. I COULDN'T HAVE BEEN DOING MORE THAN 15 MPH. I HEARD A LOUD BANG AND THEN THE VAN STARTED TO MAKE A LOUD NOISE. I PUT THE VAN IN NEUTRAL AND COASTED THROUGH THE INTERSECTION. I HAD THE VAN TOWED TO BUTTERFIELD FORD. THEY TOLD ME THAT THE SPARK PLUG HAD BLOWN OUT OF THE CYLINDER, PLUG COIL BROKE IN HALF, CRACKED THE HEAD. FORD WOULD REPAIR THE VAN BUT WOULD NOT OFFER ME A WARRANTY FOR THE WORK DONE. SO, I HAD THE VAN TOWED TO A LOCAL MECHANIC WHO REPAIRED THE VAN (REFURBISHED ENGINE) FOR $4,500 AND THEY GAVE ME A 100,000 MILE WARRANTY ON THE ENGINE. *JB
Engine and Engine Cooling
Filed Apr 22, 2005116,460 milesCA
1998 FORD XLT E350 SPARK PLUGS BLEW OUT ON ENGINE.*MR UPON STARTING THE CAR IT MADE A HORRIBLE ROCKET. IT BLEW THE SPARK PLUG OUT OF THE HOOD. CONSUMER SENT A FEW INTERNET ARTICLES CONCERNING THIS PROBLEM. FORD ENGINE-SPARK PLUG DEFECT. *BF
Fuel System, Gasoline › Storage › Tank Assembly
Filed Jan 19, 200578,000 milesCT
THE VEHICLE HAD A CRACKED FUEL TANK. CURRENTLY, THE MANUFACTURER IS CONDUCTING A RECALL FOR THIS DEFECT. HOWEVER, BASED ON THE INFORMATION PROVIDED BY THE CONSUMER, THE MANUFACTURER DID NOT INCLUDE THIS VEHICLE IN THE RECALL ALTHOUGH IT HAS ALL THE SYMPTOMS AS THOSE WHICH ARE INCLUDED. PROVIDE FURTHER DETAILS. *JB RECALL CAMPAIGN; NHTSA CAMPAIGN ID NUMBER : 01V114000. THE CONSUMER STATED THAT THE FAILURE WAS REPAIRED AT HER EXPENSE. *TC
Service Brakes, HydraulicCrash
Filed Dec 24, 2003MD
BRAKE FAILURE RESULTED IN VEHICLE REAR ENDING ANOTHER VEHICLE.*MR WHILE ATTEMPTING TO STOP THE VEHICLE'S BRAKES FAILED AND AS A RESULT THE VEHICLE REAR ENDED A STOPPED VEHICLE. THE VEHICLE WAS RENTED FROM UHAUL. A UHAUL TECHNICIAN CAME AND INSPECTD THE VEHICLE. THE VEHICLE WAS THEN TOWED IN FOR REPAIRS ( OHIO TRAFFIC CRASH REPORT). *NM
Fuel System, Diesel › Storage › Tank Assembly
Filed Jul 11, 2003SC
WHEN THE CONSUMER FILLED THE GAS TANK, HE SMELLED A STRONG ODOR OF GAS, WHEN THE CONSUMER LOOKED UNDER THE VEHICLE, HE NOTICED FUEL DRIPPING OFF THE BOTTOM OF THE FUEL TANK*AK . THE CONSUMER STATED WHEN THE TANK WAS FULL IT LEAKED VERY BAD AND ONLY WHEN THE VEHICLE WAS MOVING. AS THE FUEL IN THE TANK BECAME LOW THE LEAK SLOWED DOWN, THE CONSUMER LEARNED OF A RECALL, HOWEVER THE CONSUMER WAS INFORMED NO RECALL HAD BEEN ISSUED FOR THE VEHICLE. PH *JB
No unusual pattern of severe incidents in the complaint record.
Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.
Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.
Most recent recall on file: Apr 16, 2014. Source: NHTSA Office of Defects Investigation.