Filed Jun 15, 201013 vehiclesAll In One Mobility, Inc.
Defect. ALL IN ONE MOBILITY IS RECALLING CERTAIN MODEL YEAR 1997 THROUGH 2008 CONVERSION VANS EQUIPPED WITH VMI/RICON 6-WAY POWER SEAT BASES. THERE IS A POSSIBILITY OF A DEFECTIVE WELD AT THE JOINT BETWEEN THE PIVOTING PLATE AND THE PIVOTING PLATE PIN.
Risk. THE SEAT OCCUPANT MAY BE INJURED IF THE SEAT BASE PIN WERE TO BREAK.
Remedy. ALL IN ONE MOBILITY WILL NOTIFY OWNERS AND THE VEHICLES WILL BE REPAIRED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JUNE 22, 2010. OWNERS MAY CONTACT ALL IN ONE MOBILITY AT 1-503-255-5005.
Filed Oct 13, 20094,500,000 vehiclesFord Motor Company
Defect. FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Risk. A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.
Remedy. FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL BE COMPLETED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON OCTOBER 27, 2009. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Filed Feb 4, 2008225,000 vehiclesFord Motor Company
Defect. FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.
Risk. AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.
Remedy. DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
Filed Aug 3, 20073,600,000 vehiclesFord Motor Company
Defect. ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.
Risk. THIS COULD RESULT IN AN UNDERHOOD FIRE.
Remedy. DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.
Defect. ON CERTAIN VANS EQUIPPED WITH SURE-LOK WHEELCHAIR SECUREMENT SYSTEMS, THE SPROCKET TEETH OF THE RETRACTOR ASSEMBLY IS OUT OF ALIGNMENT.
Risk. IN THE EVENT OF A VEHICLE CRASH, THE WHEELCHAIR MAY NOT BE ADEQUATELY SECURED POSSIBLY RESULTING IN INJURIES TO A WHEELCHAIR OCCUPANT.
Remedy. DEALERS WILL INSPECT AND REPLACE THE WHEELCHAIR SECUREMENT RETRACTORS AS NECESSARY. SURE-LOK WILL HANDLE THE REPAIRS FOR THIS CAMPAIGN. OWNERS SHOULD CONTACT SURE-LOCK AT 1-908-231-1804 OR MOBILITYWORKS AT 1-800-769-8267.
Fuel System, Gasoline › Storage › Tank Assembly01V114000
Filed Apr 5, 2001151,000 vehiclesFord Motor Company
Defect. VEHICLE DESCRIPTION: ON CERTAIN VANS WITH AMBULANCE PREP PACKAGES OR OTHER SEVERE-DUTY APPLICATIONS INVOLVING OPERATION AT OR NEAR THE GROSS VEHICLE WEIGHT WITH FREQUENT TWISTING OF THE VEHICLE BODY, SUCH AS OFF-ROAD, ROUGH ROAD OR SPEED BUMP EVENTS, THE 35 GALLON MID-SHIP FUEL TANK COULD DEVELOP A CRACK WHERE IT CONTACTS THE FRAME CROSS MEMBER. IF THE FUEL TANK CRACKS, FUEL LEAKAGE COULD OCCUR.
Risk. FUEL LEAKAGE IN THE PRESENCE OF AN IGNITION SOURCE COULD RESULT IN A FIRE.
Remedy. DEALERS WILL INSPECT THE FUEL TANK AND, IF CRACKED, WILL REPLACE THE TANK. INSULATOR PADS WILL BE INSTALLED ON ALL VEHICLES TO REDUCE THE STRESS LEVELS IN THE FUEL TANK. OWNER NOTIFICATION BEGAN APRIL 19, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.
All 6 campaigns on file, newest first.
What owners reported
Newest filings
Air Bags1 injured
Filed Nov 19, 2024TX
The contact owns a 1997 Ford E-150. The contact stated that after parking the vehicle in a parking lot, the contact leaned over to the passenger’s side to pick up the cell phone. The contact stated that after sitting back straight in the seat, the air bag deployed unintendedly and without impact. No warning lights were illuminated. The contact’s eyes and jaw were injured and required medical attention. The contact’s vision became blurry but has since started to improve. The vehicle was not taken to a local dealer. The vehicle was not repaired. The manufacturer was not made aware of the failure. The failure mileage was unknown.
Tires
Filed Jul 6, 2021150,258 milesTX
The contact owns a 1997 Ford E-150 equipped with Milestar Tires, Tire Line: Grantland, Tire Size: 235/75/R15, DOT number: TB20R028. The contact stated while driving approximately 45-50 mph, the tires were bouncing. The contact stated upon checking the tires, his son noticed that the tires were cracked and had holes. The vehicle was taken to an independent mechanic who informed the contact that the tires were defective. The tires were not replaced. The manufacturer was not made aware of the failure. The approximate vehicle mileage was 150,258. The approximate tire failure mileage was 800.
Air Bags1 injured
Filed Feb 11, 2019200,000 milesTX
MY HUSBAND HAD JUST STARTED UP HIS E150 ECONOLINE VAN PULLING OUT OF THE DRIVEWAY AND THE AIRBAG JUST DEPLOYED. THERE WAS NO REASON HE WAS NOT IN ANY ACCIDENT HE DID NOT RUN OVER ANYTHING HE DIDN'T HIT ANYTHING. AND NO ONE CAN TELL ME WHY THIS HAPPENED. IF HE HAD BEEN ON THE INTERSTATE THAT HE DRIVES EVERY DAY HE COULD HAVE DIED OR KILLED SOMEONE.
Steering
Filed Sep 7, 2017150,000 milesMN
WHILE BACKING OUT OF TIGHT PARKING SPOT 9/1/17, WITH MULTIPLE TURNS OF THE WHEEL, TURNED WHEEL ONE LAST TIME TO PULL FORWARD INTO PARKING SPOT DRIVE AREA BUT AT THAT POINT, HEARD A CLUNK AND ALL STEERING CONTROL WAS GONE. CALLED FOR A TOW. TOW TRUCK DRIVE ASSISTED IN THE DIAGNOSIS NOTING THAT THE STEERING BOX HAD DISCONNECTED FROM VAN FRAME RENDERING STEERING WHEEL CONNECTION LINES USELESS. HAD VAN TOWED HOME. AFTER ONLINE READ, LOOKED AT FRAME THROUGH LEFT FRONT TIRE ACCESS AND SAW THE 3 BOLTS WE READ ABOUT. GRABBED THE TOP BOLT AND IT CAME RIGHT OUT. SAME WITH SECOND BOLT. LAST (THIRD) BOLT WAS A BIT JAMMED DUE TO THE STEERING BOX DROP, BUT ALL 3 BOLTS HAD SHEARED AND ALL STEERING WAS LOST. HAD WE NOT STOPPED AT A STORE FOR LABOR DAY HOLIDAY SUPPLIES ON OUR WAY TO CAMPSITE, WOULD HAVE LOST STEERING SOMEWHERE ELSE, LIKE ON THE FREEWAY, POSSIBLY DURING A SIMILAR TURN SITUATION. WE COULD HAVE KILLED OTHERS OR OURSELVES. FOUND THAT THIS FORD E150 STEERING BOLT ISSUE HAS ALREADY BEEN DOCUMENTED. WHY WHEN WE HAD THE VAN SERVICED AND SAID THE STEERING HAD FELT "LOOSE", WHY DIDN'T ANY MECHANIC FIND THIS POTENTIAL?? UN-EXCUSABLE SITUATION. OUR PARENTS, CHILDREN AND GRANDCHILDREN ARE CURRENTLY DEPENDENT ON US. HAD WE DIED DUE TO LOSS OF STEERING, WHAT A NIGHTMARE THAT WOULD HAVE BEEN. GRANTED, THE 20-YR-OLD VAN IS RUSTY, BUT WE DIDN'T KNOW TO LOOK UNDER THE LEFT FRONT TIRE AREA AND APPARENTLY, MULTIPLE (NON-FORD DEALERSHIPS) MECHANICS DIDN'T EITHER !!
Structure › Body
Filed Dec 8, 2016167,380 milesNJ
DRIVING ON BESTBUY PARKING LOT, WENT OVER A SPEED BUMPER HEARD A LOUD CLUNK COMING FROM DRIVER SIDE FRONT TIRE. DROVE HOME, STOPPED VAN, GOT HELP, WHILE TURNING THE STEERING TO LEFT, LOUD METAL CLUNK FROM THAT DRIVER SIDE, HELPER ON FLOOR NOTICED THAT BOTTOM BOLT HOLDING POWER STEERING BOX IS GOING IN AND OUT, RUSTED ON FRONT AND BACK OF FRAME, THIS BOX SHOULD BE MOUNTED ON REINFORCED BRACKETS FRONT AND BACK OF FRAME THEN WELDED TO FRAME TO PROTECT OCCUPANTS FROM POSSIBLE SEPARATION OF BOX AND FRAME WITH CONSEQUENT LOSS OF CONTROL AND POSSIBLE ACCIDENT (COULD BE FATAL WHEN DRIVING THE VEHICLE). SO, WITH THE ENGINE ON, IN PARK, IF THE STEERING IS TURN TO THE LEFT, DRIVER WILL FEEL AND HEAR THE CLUNK. *TR
Steering
Filed Mar 2, 2015OH
GEARBOX BOLTS BROKE AWAY FROM FRAME CAUSING LOSS OF STEERING. *TR
Suspension
Filed Jan 9, 2015163,000 milesOH
I HAVE JUST RECENTLY LOST THE REAR SHOCK MOUNT DUE TO TOO EXTREME RUST OF THE FRAME, FORD DOES NOT MAKE A REPLACEMENT PART FOR THIS. AND THE FRAME IS NOW CRACKING IN TWO. CONTACTED THE DEALER AND WAS TOLD TO BUY A NEW FRAME REALLY. WELL IT WILL NOT BE LONG TILL THE OTHER SIDE GOES. OR MY FRAME BREAKS IN TWO AND CAUSES SERIOUS INJURY TO ME OR OTHERS. THIS IS A COMMON PROBLEM WITH THIS YEAR TRUCK AND FORD DON'T SEEM TO CARE. IF THE FRAME NEEDS REPLACED IT SHOULD BE AT THEIR EXPENSE NOT MINE RECALL TIME. THEIR ARE HUNDREDS OF THOUSANDS STILL ON THE ROAD I AM NOT THE ONLY ONE. *TR
Power Train
Filed Nov 20, 2013280,000 milesAL
TL* THE CONTACT OWNS A 1997 FORD E150 VAN. THE CONTACT STATED THAT WHILE DRIVING APPROXIMATELY 40 MPH, THE SPARK PLUG BECAME DISENGAGED FROM THE ENGINE. THE VEHICLE STARTED MAKING A LOUD NOISE WITHOUT WARNING. THE FAILURE WAS RECURRING. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC, WHO DIAGNOSED THAT THE ENGINE HEAD NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT AWARE OF THE FAILURE. THE VIN WAS NOT AVAILABLE. THE APPROXIMATE FAILURE MILEAGE WAS 280,000.
Electrical SystemFire
Filed Apr 29, 2013220,000 milesKY
THE VEHICLE HAD BEEN PARKED FOR ABOUT 1 HOUR WHEN AN EXPLOSION INCURRED WHICH RESULTED IN THE TRUCK BURNING UP. THE MOTOR AREA, FRONT WHEELS AND COMPLETED CAB WERE DESTROYED. GAS TANK DID NOT BLOW UP. *TR
Fuel System, Gasoline
Filed Mar 12, 201390,000 milesTN
THIS IS THE EXACT SAME SITUATION OTHERS HAVE EXPERIENCED ON NHTSA RECALL CAMPAIGN NUMBER 01V114000 RELATING TO CRACKS/LEAKS TO THE 'MID SHIP' STYLE FUEL TANK. MY VAN IS A 1997 E-150 CONVERSION VAN. UNFORTUNATELY, I AM IN THE SAME SITUATION AS MANY OTHERS IN THE FACT THAT FORD MOTOR COMPANY DOES NOT ACKNOWLEDGE MY PARTICULAR VIN NUMBER IS AFFECTED IN THIS RECALL. THERE HAVE BEEN A NUMBER OF OTHER INCIDENTS REPORTED WITH VEHICLES MYSTERIOUSLY CATCHING ON FIRE FOR UNKNOWN REASONS. VERY DISTURBING THAT A MANUFACTURER WOULD NOT AGREE TO REPLACE A LEAKING/DAMAGED FUEL TANK. *TR
Engine
Filed Jul 10, 2012125,000 milesOH
WHILE TRAVELING ON VACATION 600 MILES FROM HOME I EXPERIENCED A WELL KNOWN FAILURE TO FORD TRITON ENGINE OWNERS KNOWN AS A SPARK PLUG EJECTION FAILURE. I WAS TRAVELING @ 65 MPH AND UP TO THE FAILURE THE ENGINE WAS RUNNING NORMAL THERE WERE NO ABNORMAL SOUNDS. AT THE TIME OF THE FAILURE IT SOUNDED AS IF THE EXHAUST OR THE INTAKE WAS COMING APART. I PULLED OVER ON THE SIDE OF THE HIGHWAY AND REMOVED THE DOGHOUSE AT THE REAR OF THE ENGINE TO DISCOVER THE RIGHT BANK AND 2ND CYLINDER FROM THE REAR HAD EJECTED THE SPARK PLUG AND DESTROYED THE IGNITION COIL. I UNPLUGGED THE IGNITION COIL AND THE POWER CABLE FROM THE FUEL INJECTOR FROM THAT CYLINDER AND NURSED THE VAN TO A FRIENDS HOUSE 40 MILES AWAY WHICH TOOK OVER 3 HOURS. I CALLED SEVERAL FORD DEALERS TO EXPLAIN WHAT HAPPENED AND THEY FINISHED THE STORY FOR ME, THEY SAID THEY HAVE SEEN THIS PROBLEM SEVERAL HUNDRED TIMES AND THE FIX WOULD COST $1000.00 PER CYLINDER NEEDING REPAIRED. THIS IS A KNOWN FORD TRITON FLAW AND SHOULD BE ADDRESSED BY FORD WITH A RECALL. THIS COULD BE A SAFETY ISSUE BECAUSE WHEN THE SPARK PLUG LET GO THERE WAS A EXTREME LOSS OF POWER IF IN HEAVY TRAFFIC THIS COULD CAUSE A ACCIDENT, AND THE RAW FUEL COMING FROM THE CYLINDER ALONG WITH SPARK FROM A LIVE IGNITION COIL IS A FIRE HAZARD. *TR
Service Brakes, HydraulicCrash
Filed Apr 9, 2012172,000 milesMI
TL* THE CONTACT OWNS A 1997 FORD E-150. THE CONTACT WAS DRIVING 5 MPH WHEN THE BRAKES WERE DEPRESSED AND THE VEHICLE FAILED TO STOP PROPERLY, CAUSING THE CONTACT TO CRASH INTO ANOTHER VEHICLE. THE VEHICLE WAS NOT DESTROYED AND THE CRASH CAUSED NO INJURIES. THE VEHICLE WAS TAKEN TO A PRIVATE MECHANIC. THE MECHANIC CONFIRMED THAT THE ABS CONTROLLER FAILED AND NEEDED TO BE REPLACED. THE MANUFACTURER WAS NOT CONTACTED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGES WERE 172,000.
Steering
Filed Oct 25, 2011162,000 milesVA
TL* THE CONTACT OWNS A 1997 FORD E-150. THE CONTACT STATED THAT THE STEERING BOX DETACHED FROM THE FRAME OF THE VEHICLE WHILE THE CONTACT WAS DRIVING. THE DEALER AND MANUFACTURER WERE NOTIFIED, BUT DENIED ANY ASSISTANCE WITH REPAIRS TO THE DEFECT. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 162,000.
Fuel System, GasolineFire
Filed Sep 1, 201189,900 milesMI
WHILE DRIVING MY VEHICLE CAUGHT ON FIRE IN THE REAR END OF THE VEHICLE. WE PULLED OVER AND IMMEDIATELY GOT THE CHILDREN OUT OF THE CAR. LESS THAN A MINUTE LATER, THE ENTIRE VEHICLE WAS BLAZING. *TR
Fuel System, Gasoline
Filed Jul 11, 2011MI
I HAVE AN 1997 FORD F150 THAT I HAD TO REPLACE THE GAS TANK AND BOTH STRAPS THAT SECURED THE TANK TO THE VEHICLE. THE STRAPS WORE AWAY AT THE GAS TANK WHICH IN TURN CAUSED A FUEL LEAK IN THE TANK ITSELF. *TT
Exterior Lighting
Filed Dec 2, 2010100,000 milesMI
TL*THE CONTACT OWNS A 1997 FORD E-150. THE CONTACT STATED THAT THE HEADLIGHTS WERE NOT BRIGHT ENOUGH AND CAUSED HIM TO USE THE HIGH BEAMS. THE DEALER WAS NOT NOTIFIED. THE CONTACT DID NOT INFORM THE MANUFACTURER. THE HEADLIGHTS WERE REPLACED; HOWEVER, THE CONTACT WAS STILL HAVING THE SAME ISSUE. THE CURRENT MILEAGE WAS APPROXIMATELY 300,000. THE FAILURE MILEAGE WAS APPROXIMATELY 100,000. UPDATED 1/19/2011 THE CONSUMER STATED THE HEADLIGHT LENSES BECAME CLOUDY OVER TIME WHICH CAUSED POOR LIGHTING WHILE DRIVING. UPDATED 03/25/11
Fuel System, Gasoline › Storage › Tank Assembly
Filed Aug 29, 201071,289 milesCA
HI, THE PART FAILURE IS A FUEL TANK CRACK THAT OCCURS IN THE MID90'S TO EARLY 2000S FORD VANS. THIS DESIGN PROBLEM HAS BEEN ADMITTED TO BY FORD, AND IS ADDRESSED ON A VERY LIMITED LIST OF CERTAIN MODELS AND YEARS UNDER A RECALL NOTICE 01V114000. HOWEVER, THIS TANK CRACK OCCURS ON OTHER NON LISTED VIN NUMBERS AS WELL, SUCH AS MINE. THIS IS THE PROBLEM, THE DOCUMENTED AND COVERED RECALL GROUP VIN NUMBERS PRECEDE MINE AND OCCUR SUBSEQUENT TO MINE, BUT SKIP SEVERAL VINS INBETWEEN. MY CRACKED AND LEAKING FUEL TANK, AND THE RESULTING GASOLINE LEAKAGE, OCCUR AS A RESULT OF THE TANK DESIGN, WHICH DESIGN FORD HAS REVISITED FIVE TIMES NOW. SO, THERE IS A GASOLINE LEAK THAT RESULTS FROM METAL FATIGUE, AS THE LONG "HOTDOG" SHAPED FUEL TANK FLEXES AND TWISTS, IN FORD'S WORDS, WITH THE FRAME, AND FAILS WHERE IT RUBS STRAPS OR CROSSMEMBERS. I HAVE ATTEMPTED TO GET A REPLACEMENT TANK FROM FORD, BUT ALL ARE SPOKEN FOR AND BACKORDERED AS THEY ARE BEING SUPPLIED TO THE DEALERS FOR THE VEHICLES INCLUDED IN THE CURRENT LIST OF DEFECTIVE VEHICLES. SO, NO TANKS ARE AVAILABLE TO PEOPLE LIKE ME, WHO HAVE THE PROBLEM, BUT ARE NOT INCLUDED IN FORD'S EXISTING RECALL LIST. I HAVE CONTACTED FORD FOR RESOLUTION, FORD CASE 599552380, FOR SOURCING A TANK AT LEAST FOR NOW. FORD WILL STILL NOT ADMIT TO OWNERSHIP OF FINANCIAL RESPONSIBILITY FOR THIS PARTICULAR TANK--YET. I HAVE ALSO FILED A COMPLAINT WITH DOT, CASE #290654, TO HAVE THE RECALL GROUP EXPANDED TO COVER ALL OF US WHO NEED THIS HELP. AS AN ASIDE, TH
Fuel System, Gasoline › Delivery › Hoses, Lines/Piping, and Fittings
Filed Aug 26, 201071,289 milesCA
TL* THE CONTACT OWNS A 1997 FORD E-150. THE CONTACT STATED THAT THE FUEL LINE WAS FRACTURED AND RAPIDLY LEAKING GASOLINE FUEL. THE CONTACT WAS INFORMED OF A POTENTIAL RECALL ON THE VEHICLE BY HIS INDEPENDENT MECHANIC (NHTSA CAMPAIGN ID NUMBER: 01V114000) BUT WAS ADVISED BY THE MANUFACTURER THAT HIS VIN WAS NOT INCLUDED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 71,289.
Tires
Filed Jun 1, 2010185,000 milesFL
I HEARD A LOUD POP AND DROVE ANOTHER 100 YARDS TO MY SONS HOUSE AND THE TIRE WENT FLAT WITHIN ONE MINUTE. IT HAS STEEL BANDS STICKING OUT OF A SPLIT IN THE TIRE. IT HAS A DIP IN THE TREAD AND SIDEWALL WHERE THE STEEL BAND HAS BROKE. THE TIRE IS NOT CUT IT IS SPLIT. THIS WAS ONE OF TWO ON THE REAR , THE OTHER IS STILL ON. I HAVE THE TIRE./ I PUT ON THE SPARE, AND CAME HOME. *TR
Service Brakes, Hydraulic
Filed Nov 23, 200958,163 milesMA
THE BRAKE LINES HAVE FAILED IN THREE SEPARATE LOCATIONS OVER THE PAST 6 MONTHS. FORTUNATELY, IT HAS NOT RESULTED IN ANY ACCIDENTS. NO CONFIDENCE IN THE BRAKE LINES ON THIS VAN. *TR
Fuel System, Gasoline › Storage › Tank Assembly
Filed May 12, 200989,000 milesME
TL*THE CONTACT OWNS A 1997 FORD E-150. WHILE PLACING FUEL INTO THE VEHICLE, THE CONTACT NOTICED A HUGE PUDDLE UNDERNEATH THE VEHICLE. HE LOOKED UNDERNEATH THE VEHICLE AND NOTICED A CRACK ON THE FUEL TANK. THE MANUFACTURER STATED THAT HIS VIN WAS EXCLUDED FROM NHTSA CAMPAIGN ID NUMBER 01V114000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE CONTACT BELIEVES THAT HIS VEHICLE SHOULD BE INCLUDED IN THE RECALL SINCE THE FAILURES ARE IDENTICAL. THE FAILURE MILEAGE WAS 89,000 AND CURRENT MILEAGE WAS 94,000.
Fuel System, Gasoline
Filed Dec 30, 2008126,000 milesSC
TL*THE CONTACT OWNS A 1997 FORD E-150. FOR A MONTH, THE CONTACT SMELLED GASOLINE WHEN ENTERING, EXITING, AND DRIVING THE VEHICLE. HE DROVE THE VEHICLE TO A FUEL STATION AND GASOLINE SPILLED TO THE GROUND WHILE PUMPING FUEL INTO THE TANK. THE FUEL TANK WOULD NOT FILL UP PAST HALF A TANK. THE VEHICLE WAS DRIVEN TO THE CONTACT'S RESIDENCE. THE VEHICLE HAS NOT BEEN INSPECTED AND THE CAUSE OF THE FAILURE HAS NOT BEEN DETERMINED. THE DEALER STATED THAT THEY WOULD REPAIR THE VEHICLE, BUT AT THE CONTACT'S EXPENSE. THE MANUFACTURER HAS NOT BEEN NOTIFIED. THE CURRENT AND FAILURE MILEAGES WERE 126,000.
Tires › Sidewall
Filed May 20, 2008100,000 milesOH
TL*THE CONTACT OWNS A 1997 FORD E-150. THE VEHICLE HAS COOPER DISCOVERER A/T TIRES, SIZE P235/70R25. ANOTHER DRIVER NOTICED A BUBBLE ON THE CONTACT'S TIRE. THE TIRE THEN BLEW OUT ON THE WAY TO THE TIRE SHOP. THE CURRENT AND FAILURE MILEAGES WERE 100,000. UPDATED 06/16/08 *BF
Power Train › Automatic Transmission › Gear Position Indication (prndl)
Filed May 12, 2008175,000 milesGA
IN MY 1997 FORD F-150 4.6 LTR. AUTO TRANSMISSION I HAVE BEEN HAVING SOME ISSUES IN THE PAST COUPLE OF MONTHS WITH SELECTING DRIVE OR REVERSE WITH MY GEAR SHIFT. ALSO THE VEHICLE WAS NOT STARTING ON OCCASION BECAUSE THE SHIFTER WASN'T ALL THE WAY IN PARK. WHEN YOU SHOVE IT IN PARK IT WOULD WORK, I FIGURED I WAS GOING TO BE REPLACING THE TRANSMISSION SOON. TONIGHT THE TRUCK WILL NOT GO IN PARK AND I AM HAVING TO START THE ENGINE IN NEUTRAL AND KEEP THE EMERGENCY BREAK ON. THIS CAN BE A VERY DANGEROUS PROBLEM BECAUSE IF THE EMERGENCY BREAK IS NOT ON OR FAILS THEN IT COULD CAUSE DAMAGE. I HAVE NOT YET FIXED THE PROBLEM BUT WILL HAVE IT DONE TOMORROW! *TR
Vehicle Speed ControlFire
Filed Apr 13, 2008PA
PURCHASED USED 1997 FORD 150 IN EARLY 2005. DROVE TRUCK TO WORK IN SEPTEMBER 2007. SMOKE ENGULFED CAB. TRUCK CAUGHT FIRE AND BURNT TO GROUND. THE TRUCK WAS A TOTAL LOSS ALONG WITH CONSTRUCTION EQUIPMENT. LIABILITY INSURANCE DID NOT COVER EXPENSE. STILL PAYING FOR A TRUCK THAT I DO NOT HAVE. POLICE REPORT WAS FILED. NEVER RECEIVED RECALL NOTICE UNTIL AFTER TRUCK CAUGHT FIRE. *TR
Vehicle Speed Control
Filed Mar 10, 200845,000 milesWI
FORD RECALL 05S28 SPEED CONTROL RECALL; MY LETTER IS DATED AUG 2007 STILL WAITING FOR DEALERSHIP TO RECEIVE THE PART FOR THIS RECALL TRIED MANY DEALERSHIPS IN THE MILWAUKEE AND MADISON AREA WITH NO STOCK AND NO ETA OF PART CALLED FORD WITH NO ANSWER AS WELL. *TR
Vehicle Speed Control
Filed Jan 8, 2008KS
TL*THE CONTACT OWNS A 1997 FORD E-150. THE CONTACT RECEIVED A FORD VEHICLE SPEED CONTROL SAFETY RECALL NOTICE IN AUGUST OF 2007. HE WOULD LIKE TO KNOW WHEN FORD WILL HAVE THE PARTS TO PERFORM THE RECALL REPAIR. THERE HAD BEEN NO FAILURE TO DATE. THE PURCHASE DATE WAS UNKNOWN. THE CURRENT MILEAGE WAS 128,000. UPDATED 01/29/08. *LJ UPDATED 01/29/08 *TR
Engine and Engine Cooling › Engine
Filed Dec 30, 200713,500 milesSC
HAVE 1997 F-150,WENT ON VACATION, TRUCK RAN FINE. CAME BACK AND WENT TO PICK UP DOG FROM KENNEL, AND BOOM, HYDRO-LOCK. *TR
Engine and Engine Cooling › Engine › Gasoline
Filed Dec 7, 2007135,039 milesCA
I EXPERIENCED THE SAME SYMPTOMS DESCRIBED IN THE CAMSHAFT POSITION SENSOR RECALL WHICH AFFECTS E-SERIES VANS. ON 05NOV07 MY ENGINE LIGHT CAME ON AND MY ENGINE BEGAN TO HESITATE, AS IF IT WOULD STALL. I TOOK THE VAN TO THE FORD DEALER ON 06NOV07. THEY SAID THEY COULD NOT FIND ANYTHING WRONG. THEY RESET THE CODES AND THE ENGINE LIGHT WENT OFF. ON 09NOV07 THE ENGINE LIGHT CAME ON AGAIN AND THE ENGINE BEGAN TO RUN SLUGGISHLY. I DID NOT DRIVE THE VAN OVER THE WEEKEND BECAUSE I WAS AFRAID IT WOULD STALL WHILE I WAS DRIVING. ON 12NOV07 THE DEALER REPLACED THE DPFE SENSOR AT A COST TO ME OF $364.04. I CONTACTED FORD CORPORATION ON 06DEC07 REQUESTING REIMBURSEMENT FOR THE REPAIR. MY REQUEST WAS DENIED. FAILURE OF DPFE SENSOR HAS THE SAME RESULTS AND THE SAME SAFETY IMPLICATIONS AS THE FAILURE OF THE CAMSHAFT POSITION SENSOR. FORD SHOULD INCLUDE THIS FAILURE IN THE RECALL AS WELL, OR SOMEONE WILL BE HURT EVENTUALLY. *TR
Electrical System › WiringFire
Filed Jul 12, 2007150,000 milesOK
1997 FORD F150 CAUGHT ON FIRE WILL IT WAS PARKED AT MY SONS WORK. *AK
Fuel System, Gasoline › Storage › Tank Assembly
Filed Mar 23, 200793,801 milesIL
GAS SPILLED OUT OF THE ORIGINAL FUEL TANK WHILE FILLING UP ON FLAT GROUND. DEALER SAID THE TANK HAD RUBBED ON A CROSS MEMBER AND HAD A HOLE IN THE TANK.*AK
Engine and Engine Cooling › Exhaust System › Manifold/Header/Muffler/Tail Pipe
Filed Mar 18, 200748,008 milesPA
ENGINE HYDRO-LOCK. I OWN A 1997 E-150 CONVERSION VAN. IT HAS THE 4.2L V-6 ENGINE. I HAVE HAD TO HAVE THE INTAKE MANIFOLD GASKET REPLACED ALONG WITH THE WATER PUMP AND GASKET AND ALSO TIMING GEAR GASKET. ALL DUE TO A FAULTY INTAKE MANIFOLD GASKET. FORD REPLACED THIS IN THE V-8 MODEL CARS DUE TO READING A LAWSUIT ABOUT IT ON THEIR SITE. I HAVE READ IN MANY FORUMS THAT I'M NOT ALONE IN THIS COSTLY REPAIR. I CONTACTED FORD TO BE TOLD THAT THE LAWSUIT DID NOT PERTAIN TO MY VAN. SINCE I'M NOT ALONE, I WOULD LIKE TO KNOW WHAT IF ANYTHING CAN I DO? HTTP://WWW.FORDMANIFOLDSETTLEMENT.COM/INDEX.HTML HTTP://FORUMS.TREEMEDIA.COM/FB/ARCHIVE/INDEX.PHP/T-224.HTML
Engine and Engine Cooling › Engine
Filed Mar 3, 2007131,000 milesME
SPARK PLUG BLOW OUT IN A 1997 FORD F 150 PICK UP TRUCK WITH A 5.4 V8. *JB
Electrical System
Filed Feb 24, 200798,000 milesFL
MY VAN HAS BEEN IN THE SHOP 3 TIMES AND THEY TELL ME I NEED TO CLEAN THE INJECTORS. WELL IT HAS BEEN STARTING SLUGGISH FROM DAY ONE. TODAY IT WILL NOT START. SAME SYMPTOMS AS EVERYBODY ELSE. WEAK BATTERY AND SMOKE STILL WILL NOT START. I'M AFRAID TO DRIVE IT AGAIN. I THINK IT'S GOING TO CATCH ON FIRE. *JB
Engine and Engine Cooling
Filed Sep 18, 2006144,000 milesFL
ENGINE COOLANT LEAKED INTO CYLINDER DUE TO GASKET FAILURE CAUSING PISTON ROD TO BEND. I HAVE LEARNED THAT THIS IS ALL TO COMMON PROBLEM WITH 1997 4.2 V6. I AM UNABLE TO HAVE MY TRUCK REPAIRED AT THIS TIME .THE ENGINE NEEDS TO BE REPLACED $4,000.00. *JB
Engine and Engine Cooling › Engine › Gasoline
Filed Jul 2, 2006125,946 milesIL
MY 97 FORD E150 HAS THE 5.4 MOTOR IN IT. THE PROBLEM I AM HAVING IS SPARK PLUG BLOW OUTS. THIS IS MY SECOND IN A YEARS TIME. THIS COULD CAUSE A FIRE DUE TO RAW FUEL COMING OUT OF THE SPARK PLUG HOLE AND THE COIL LAND ON THE HEAD COULD CASE A SPARK AND BOOM BAD FIRE. *NM
Fuel System, Gasoline › Storage › Tank Assembly
Filed Mar 8, 200645,000 milesOK
FORD'S RECALL NUMBER IS 01S14. MY E150 FILLS THE REQUIREMENTS OF "NEAR THE GROSS VEHICLE WEIGHT WITH ... ROUGH ROAD... THE 35 GALLON MID-SHIP FUEL TANK ... CRACK ... " FORD TELLS ME THAT MY VIN IS OUTSIDE THE RANGE OF COVERED VANS. THE RECALL COVERS 1997 THROUGH 2001 MODELS. I SEE NO WAY THAT FORD WOULD KNOW WHICH VANS ARE USED IN THE ABOVE MENTIONED MANNER. THIS PROBLEM APPEARED FROM THE BEGINNING OF MY OWNERSHIP. ANY FILLING OF MORE THAN 3/4 TANK, RESULTED IN STRONG GASOLINE SMELL AND LEAKAGE. THIS WAS A VERY SERIOUS PROBLEM. EVEN THOUGH I TRIED TO NOT FILL PAST 3/4, SOMETIMES I WOULD EXCEED THAT. EXPLOSION AND FIRE WERE CONSTANT THREATS. MY FORD DEALER TELLS ME THAT IT CERTAINLY LOOKS LIKE MY VAN SHOULD BE INCLUDED. I AGREE. I HAVE PAID FOR THE REPLACEMENT OF THE FUEL TANK. THE BELOW INCIDENT DATE IS APPROXIMATE. I BOUGHT THE VAN IN DECEMBER 2001. *JB
Fuel System, Gasoline › Storage › Tank Assembly
Filed Nov 29, 2005170,000 milesOH
I HAD A FUEL TANK LEAK ON MY FORD E150 CONVERSION VAN IN 2001. THE VAN HAD 85000 MILES ON IT. HAD THE TANK REPLACED AT A DEALER; ORIGINALLY HE ORDERED THE WRONG TANK, THINKING I HAD THE SMALLER ONE, BUT I HAVE THE 35 GAL. MIDSHIP TANK LISTED IN 01V114000. THEY REPLACE THE TANK ABOUT THE TIME THIS RECALL WAS ISSUED. THEN, 85000 MILES LATER, I HAVE THE SAME LEAK, EXACT SAME PROBLEM. I HAVE VISITED TWO DEALERSHIPS, EVEN SPOKEN TO THE ORIGINAL SERVICE MANAGER WHO HANDLED THE REPAIR IN 2001; ALL DENY THAT THE RECALL APPLIES TO THIS VEHICLE. I CALLED FORD AT THE NUMBER LISTED IN 01V11400; THEY DENY THAT I HAVE THIS FUEL TANK, EVEN THOUGH THEY INSTALLED IT SPECIFICALLY, ALTHOUGH OBVIOUSLY NOT ACCORDING TO THE RECALL INSTRUCTIONS. I FIGURE BECAUSE IT WAS A CONVERSION VAN THEY MAY NOT THINK IT WAS THE "ORIGINAL EQUIPMENT". I HAVE NOW HAD THIS PROBLEM TWICE, AND PAID FOR IT THE FIRST TIME. I WANT THEM TO REIMBURSE ME FOR THE ORIGINAL REPAIR UNDER THIS RECALL, AND THEN TO PERFORM THE RECALL REPAIR CORRECTLY, SINCE OBVIOUSLY THAT WASN'T DONE. I'M SURE THIS FUEL TANK LEAK HAS COST ME A LOT IN EVAPORATED GASOLINE TOO, PARTICULARLY AT TODAY'S PRICES. *NM
Fuel System, Gasoline › Storage › Tank Assembly
Filed Nov 25, 2005103,000 milesFL
1997 FORD ECONOLINE 150 UNIVERSAL CONVERSION VAN. GAS TANK ROTTED OUT AT FILLER TUBE. GAS RUNS OUT ON GROUND WHILE FILLING. GAS TANK HAD TO BE REPLACED. *NM
Service Brakes, Hydraulic › Foundation Components › Hoses, Lines/Piping, and Fittings
Filed Nov 14, 2005104,700 milesNY
BRAKES LINES BURST AND BRAKES ON VAN FAILED. ALL THE BRAKE LINES ARE ROTTED AND HAVE TO BE REPLACED. *JB
Service Brakes, Hydraulic › Antilock/Traction Control/Electronic Limited Slip
Filed Sep 23, 2005PA
DT: THE CONTACT OWNS A 1997 FORD E150. ALL OF THE BRAKE FLUID WAS LOST THROUGH THE REAR BRAKE LINES. THE MECHANIC DESCRIBED IT AS CORRODED, RUSTED LINES. THE CONSUMER REPORTED HAVING NO PROBLEMS PRIOR TO THIS INCIDENT. HE NOTICED THIS TODAY.*AK
Fuel System, Gasoline › Storage › Tank Assembly
Filed Sep 17, 2005103,000 milesFL
1997 FORD ECONOLINE 150 UNIVERSAL CONVERSION VAN. GAS LEAKS AT GAS TANK WHEN FILLING UP. THE MAIN FILLER TUBE ( HOSE) SEEMS TO BE LEAKING. GAS RUNS OUT ALL OVER THE GROUND. GAS TANK MUST BE DROPPED TO REPLACE HOSE. *JB
Steering
Filed Jul 22, 2005TN
DT: CONTACT STATES BECAUSE OF HIS DISABILITY THE VEHICLE IS HARD TO PUT INTO GEAR, ALSO IT IS HARD TO START THE ENGINE. THE VEHICLE HAS NOT BEEN TO A SERVICE DEALER.*AK *JB
Suspension › Front › Control Arm › Lower Ball Joint
Filed Jul 22, 2005105,000 milesCT
DT: CONTACT HAD BALL JOINTS PUT ON THE TRUCK WHEN IT WAS STAKEN TO TO THE DEALER FOR ALIGNMENT. . WHEN DEALER WENT TO ALIGN VEHICLE THEY FOUND A CRACK IN THE MIDDLE OF THE FRAME, ALL THE WAY FROM WHERE THE DRIVE BOX WAS TO THE DRIVER'S SIDE DOOR. ON THE CROSS MEMBER THAT HELD THE FRAME TOGETHER, THE RIVET WAS OUT OF THE FRAME. HE NOTICED THIS ON JULY 1, 2005. HE CALLED FORD TWICE, AND THEY SAID THEY COULD NOT SEND ANYONE TO LOOK AT VEHICLE BECAUSE IT WAS OUT OF WARRANTY. HE TOOK VEHICLE TO 2 AUTO BODY FRAME SHOP AND HAD IT REPAIRED. BOTH BODY SHOPS SAID THE CAR WAS NOT HIT, AND THAT HE SHOULD CONTACT FORD. HE CALLED THE DEALER, AND THEY HAD NOT CALLED HIM BACK.*AK
Power Train
Filed Jul 15, 200517,000 milesCA
MY FORD 150 WAS PURCHASED WITH THE 504 LITER ENGINE AND ALTHOUGH IT IS A 1997 MODEL HAS ONLY 19000 MILES ON IT. THE PROBLEM IS AN ENGINE OIL LEAK THAT HAS BEEN ROUGHLY DIAGNOSED AS THE MAIL SEALS BOTH FRONT AND REAR. I HAVE SPENT $300.00 TO REPLACE THE FRONT SEAL AND THE REAR SEAL HAS BEEN QUOTED TO ME AS ANOTHER $600.00. I FEEL FORD SHOULD STEP UP TO THE PLATE AND FIX THIS PROBLEM FOR ME AS I DOUBT MINE IS THE ONLY OCCURANCE OF THIS TYPE.
Engine and Engine Cooling › Exhaust System › Manifold/Header/Muffler/Tail Pipe
Filed Feb 10, 200547,800 milesIN
FORD MOTOR CO. HAD KNOWLEDGE OF FAILURE OF THE FRONT COVER GASKET AND LOWER INTAKE MANIFOLD GASKET IN 97 & 98 E-150 AND F-150 VEHICLES. FAILURE OF ANY ONE OF THE ABOVE ITEMS WILL END THE LIFE OF A ENGINE. FORD WILL NOT ACKKNOWLEDGE THIS PROBLEM EVEN THOUGH NUMEROUS TSB'S HAVE BEEN PUT OUT. THIS IS SUCH A PROBLEM THAT A WEB SITE IS DEDICATED TO IT. (LEAKINGFORDS.COM) ANOTHER SITE THAT HAS MANY COMPLAINTS ABOUT THIS IS HTTP://FORUMS.TREEMEDIA.COM/FB/SHOWTHREAD.PHP?T=224&PAGE=4&PP=15 PEOPLE THAT HAVE THIS FAILURE END UP NEEDING A ENGINE REPLACED. *AK
Service Brakes, Hydraulic › Foundation Components › DiscCrash
Filed Jan 6, 200515,000 milesPA
APPROXIMATELY EVERY 15,000 TO 20,000 MILES I NEED TO REPLACE THE FRONT ROTORS AND PADS. THE ROTORS ARE BADLY WARPPED. THE DEALER REPLACED THE CALIPERS, BUT THAT DID NOT HELP. THE REAR DRUMS ARE ORIGINAL EQUIPMENT AND HAS LITTLE WEAR. I HAVE PAID TO HAVE THE REAR DRUMS ADJUSTED REGULARLY, IN AN ATTEMPT TO IMPROVE THE LONGEVITY OF THE FRONT BREAKS. I HAVE ABOUT 140,000 MILES ON THE CAR AND REPLACE THE FRONT BRAKES 7 OR 8 TIMES. I DID HAVE ONE ACCIDENT DUE TO POOR BREAKING, AND THE NEXT DAY NEEDED TO REPLACE THE FRONT PADS AND ROTORS.*AK
Fuel System, Gasoline › Delivery › Hoses, Lines/Piping, and Fittings
Filed Dec 3, 2004NY
UPON FILLING THE GAS TANK THERE IS EXTERNAL GAS LEAKAGE.THE GAS RUNS BACK OUT ONTO THE GROUND. CONSUMER REPAIRED IT. *AK 1 1/2 INCH DIAMETER HOSE AT THE TOP OF THE FUEL TANK CRACKED. *TC
Fuel System, Diesel › Storage › Tank Assembly
Filed Aug 25, 200460,000 milesTX
THIS IS A FOLLOW UP TO MY COMPLAINT FROM LAST YEAR (ODI 10038825). I REMOVED THE GAS TANK FROM MY VAN AND FOUND THE LEAKS (SEVERAL) WERE CAUSED BY THE METAL TANK RUBBING AGAINST THE FRAME CROSS RAILS. *AK THE TANK IS METAL TO METAL CONTACT WITH THE FRAME OF THE VAN, THERE IS NO ISOLATION OF ANY KIND. THIS SEEMD TO BE A SERIOUS DESIGN FLAW (TO ME ANYWAY) AND I CALLED THE FORD MOTOR COMPANY TO LET THEM KNOW. FORD EXPRESSED NO CONCERN, SINCE THERE HAD NOT BEEN ANY DEATHS OR INJUIES REPORTED. I CAN'T BELIEVE THAT I AM THE ONLY PERSON THAT HAS EXPERIENCED THIS CONDITION. I HAVE DIGITAL PHOTOGRAPHS OF THE FRAME AND TANK, PRIOR TO HAVING IT REPAIRED. I TOOK THE TANK TO A SHOP AND HAD THE LEAKS WELDED, I ALSO CUT UP AN INNER TUBE AND PLACED IT BETWEEN THE TANK AND FRAME RAILS, TO PREVENT THIS FROM HAPPENING AGAIN. I THINK THERE ARE LOTS OF FORD VANS ROLLING ON THE ROADS OF THIS COUNTRY THAT HAVE THE SAME PROBLEM AND IT IS ONLY A MATTER OF TIME BEFORE ONE OF THEM BLOWS UP!
Engine and Engine Cooling › Engine
Filed Aug 13, 200476,099 milesTX
1) ENGINE BEGINS TO RUNS ROUGH. ) EGR PORTS BECOME CLOGGED 3) INTAKE HAS TO BE REMOVED AND PORTS CLEANED AND INJECTORS FLUSHED. WAS TOLD BY THE MECHANIC THAT THIS IS A KNOWN DESIGN FLAW WITH THE FORD 6 CYL. ENGINE, AND THAT THERE IS NOTHING THAT CAN BE DONE TO PREVENT IT. IT WILL HAVE TO BE DONE AGAIN PERIODICALLY. *AK
Complaints 1-50 of 102, newest first, reproduced as filed.
No unusual pattern of severe incidents in the complaint record.
Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.
Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.
Most recent recall on file: Jun 15, 2010. Source: NHTSA Office of Defects Investigation.