Owners filed 52 complaints about this vehicle with federal regulators, most often about the engine and engine cooling › engine › gasoline › belts and associated pulleys. It has been recalled 7 times.
What fails
Component
Reports
Crashes
Fires
Injuries
Engine and Engine Cooling › Engine › Gasoline › Belts and Associated Pulleys
5
0
0
0
Tires
4
0
1
0
Steering › Hydraulic Power Assist › Pump
4
0
0
0
Service Brakes, Hydraulic › Foundation Components
3
0
0
0
Tires › Tread/Belt
2
0
0
0
Steering
2
1
0
0
Power Train › Clutch Assembly
2
0
0
0
Fuel System, Gasoline › Storage › Tank Assembly › Filler Pipe and Cap
Filed May 24, 200627,176 vehiclesCk Motorsport, Inc.
Defect. CERTAIN CK MOTORSPORTS COMBINATION HEADLIGHTS, CLEAR CORNER, BUMPER, AND SIDE MARKER LIGHTS SOLD AS REPLACEMENT LAMPS FOR USE ON THE PASSENGER VEHICLES LISTED ABOVE. SOME COMBINATION LAMPS THAT ARE NOT EQUIPPED WITH AMBER SIDE REFLECTORS FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT.
Risk. WITHOUT THE AMBER REFLECTORS, THE VEHICLE WILL BE POORLY ILLUMINATED, POSSIBLY RESULTING IN A VEHICLE CRASH WITHOUT WARNING.
Remedy. CK MOTORSPORT WILL NOTIFY OWNERS AND REPLACE THE NONCOMPLIANT LAMPS FREE OF CHARGE. THE RECALL BEGAN ON JULY 1, 2006. OWNERS MAY CONTACT CK MOTORSPORT AT 1-909-610-7211.
Fuel System, Gasoline01I008000
Filed Jul 19, 20011,556,221 vehiclesFord Motor Company
Defect. THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN THE FUEL PUMP/SENDER ASSEMBLY. FUEL MAY BE SUPPLIED FROM ONE TANK AND SOME OR ALL OF THE UNUSED FUEL MAY BE RETURNED TO THE OTHER TANK.
Risk. SHOULD THIS OCCUR, THE CAPACITY OF THE RECEIVING TANK MAY BE EXCEEDED AND FUEL MAY OVERFLOW FROM THE FILLER CAP.
Remedy. FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE ALREADY HAS MORE THAN 150,000 MILES, THIS OVERAGE WILL LAST UNTIL DECEMBER 31, 2001. IF THE VEHICLE IS EXPERIENCING A FUEL CROSS-FLOW CONDITION, DEALERS WILL REPAIR THE CONDITION FREE OF CHARGE.
Tires › Tread/Belt01X001000
Filed May 22, 200113,000,000 vehiclesFord Motor Company
Defect. THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. EQUIPMENT DESCRIPTION: FORD IS REPLACING ALL FIRESTONE WILDERNESS AT 15, 16, AND 17 INCH TIRES MOUNTED ON FORD TRUCKS AND SUVS. FORD REPORTS TREAD SEPARATION CAN OCCUR DUE TO A COMBINATION OF THE SENSITIVITY OF THE TIRE DESIGN TO STRESS, AGING, AND MANUFACTURING DIFFERENCES BETWEEN PLANTS. FORD IS REPLACING THESE TIRES TO PREVENT POSSIBLE PREMATURE TIRE FAILURE. VEHICLE DESCRIPTION: THE VEHICLES LISTED BELOW MAY HAVE BEEN ORIGINALLY EQUIPPED WITH FIRESTONE WILDERNESS AT TIRES OR MAY HAVE HAD WILDERNESS AT TIRES INSTALLED DURING THE FIRESTONE RECALL LAUNCHED IN AUGUST 2000. CERTAIN 1991 THROUGHT 2002 FORD EXPLORER CERTAIN 2001 THROUGHT 2002 EXPLORER SPORT, AND SPORT TRAC CERTAIN 1997 THROUGH 2002 MERCURY MOUNTAINEER CERTAIN 1991 THROUGH 2001 RANGER CERTAIN 1999 THROUGH 2001 EXPEDITION CERTAIN 1991 THROUGH 1994, AND 1997 MODEL YEAR F-SERIES CERTAIN 1991 THROUGH 1994 BRONCO NOTE: BOTH ORIGINAL EQUIPMENT AND REPLACEMENT TIRES ARE AFFECTED.
Risk. SHOULD THE TREAD SEPARATE AT HIGHWAY SPEEDS, A VEHICLE CRASH COULD OCCUR, POSSIBLY RESULTING IN PERSONAL INJURY OR DEATH.
Remedy. THE REPLACEMENT/REIMBURSEMENT PROGRAM FOR THIS CAMPAIGN EXPIRED ON MARCH 31, 2002. HOWEVER, CUSTOMERS CAN CONTACT FORD AT 1-877-917-3673 OR GO ON-LINE TO WWW.FORD.COM FOR POSSIBLE ASSISTANCE.
Parking Brake › Conventional94V169001
Filed Sep 7, 1994835,791 vehiclesFord Motor Company
Defect. THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Risk. WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy. A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
Fuel System, Gasoline › Storage › Tank Assembly93V125000
Filed Aug 2, 19931,131,000 vehiclesFord Motor Company
Defect. A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Risk. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy. REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
Engine and Engine Cooling › Engine › Gasoline92V112000
Filed Aug 4, 199248,000 vehiclesFord Motor Company
Defect. THE SOUND INSULATION ON THE ENGINE SIDE OF THE DASH PANEL CAN CONTACT THE EXHAUST MANIFOLD.
Risk. CONTACT BETWEEN THE INSULATION AND THE HOT EXHAUSTMANIFOLD MAY RESULT IN A ENGINE COMPARTMENT FIRE.
Remedy. DEALERS WILL MODIFY THE SOUND INSULATOR AT NO COST TO OWNERS.
Structure › Body › Door92V006000
Filed Jan 14, 1992190,000 vehiclesFord Motor Company
Defect. WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.
Risk. THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.
Remedy. REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.
What owners reported
Newest filings
Fuel/Propulsion System
Filed Aug 7, 2017130,000 milesMT
TL* THE CONTACT OWNS A 1992 FORD F-350. WHILE FUELING THE VEHICLE, THE FUEL WAS TRANSFERRING TO THE REAR FUEL TANK AND OVERFLOWING. THE FAILURE CAUSED FUEL TO LEAK OUT ONTO THE GROUND. THE VEHICLE WAS TAKEN TO KALISPELL FORD, IN KALISPELL MT 59901, BUT THE RECALL HAD EXPIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE AND INFORMED THE CONTACT THAT THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE). THE APPROXIMATE FAILURE MILEAGE WAS 130,000.
SteeringCrash
Filed Aug 22, 2006NY
1992 FORD F-350 HAD EQUIPMENT FAILURE, CAUSING IT TO STRIKE THE MEDIAN WALL. *KB THE CONSUMER STATED A FAILURE WITHIN THE STEERING CAUSED THE ACCIDENT. *JB
Fuel System, Gasoline › Delivery › Fuel Pump
Filed Jun 4, 200445,000 milesID
THE DEFECTIVE CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILL. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO THE SOURCE OF IGNITION. *AK THE CONSUMER CONTACTED THE DEALER WHO INDICATED THAT THE RECALL HAD EXPIRED AND THAT THEY WOULD NOT FIX IT UNDER THE RECALL. *NM
Fuel System, Other
Filed Aug 12, 2003MD
CONSUMER STATES THAT VEHICLE IS LEAKING FUEL. DEALER NOTIFIED.*AK
Fuel System, Gasoline › Storage › Tank Assembly
Filed Feb 25, 2003IL
FUEL LEAKED OUT OF THE FRONT TANK.*JB
Fuel System, Gasoline › Storage
Filed Oct 28, 2002IL
CONSUMER STATES THAT WHEN THEY HAD RECALL DONE, DEALERSHIP FORGOT TO INSTALL A PART STATED IN THE RECALL. WHICH CAUSE RECALL REDEEM TO FAIL. WENT BACK, THEY CORRECTED THE PROBLEM, BUT LATER ON PROBLEM REACCURED. TS
Tires
Filed Jul 15, 2002TN
VEHICLE BEING TOWED BEHIND MOTORHOME ON I-29 NORTH OF ST.JOSEPH,MO. HEARD NOISE AND SAW SMOKE AND MOTORHOME BEGAN DRIFTING TO RIGHT. AFTER STOPPING TO INVESTIGATE FOUND LEFT FRONT TIRE BLOWN OFF WHEEL,BRAKE LINE SEVERED, RUNNING BOARD MISSING AND CONSIDERABLE DAMAGE TO LEFT DOOR AND FENDER. PUT ON SPARE THEN PROCEEDED TO PALMYRA, NE. FOR THE EVENING. JUST AFTER CROSSING IN TO WYOMING THE NEXT DAY ANOTHER LOUD REPORT AND THE LEFT REAR TIRE BLEW OUT. SAME TYPE OF TIRE AND SAME MILEAGE AS THE FRONT, ONLY THE BELT HAD WRAPPED AROUND THE AXLE AND LOCKED UP THE WHEEL. I HAVE THIS TIRE, WHAT IS LEFT OF IT ANYWAY. CONDITIONS ON BOTH OCCURANCES: CLEAR WEATHER, TEMPS IN THE MID TO HIGH 80 S, SPEED WAS 65 MPH, TRAFFIC MODERATE. TIRES WERE CHECKED AND INFLATED TO 50 PSI PRIOR TO DEPARTING BARTLETT, TN. TREAD WAS ABOUT 50% ON ALL FOUR TIRES OF THE MATCHED SET. IF VEHICLE HAD BEEN DRIVEN INSTEAD OF BEING TOWED, THIS COULD HAVE BEEN DANGEROUS TO OCCUPENTS AND OTHER MOTORISTS IN BOTH INCIDENTS .*AK
Tires
Filed Aug 28, 2001FL
TIRES SEPARATED AT THE BEAD JOINT ON EACH TIRE AFTER ONLY 3,000 TO 5,000 MILES. EXPLODED THROUGH THE TREAD CAUSING DAMAGE TO VEHICLE. HAVE USED THESE TIRES FOR YEARS WITHOUT MISHAP UNTIL ABOUT TWO YEARS AGO. PROBLEM STARTED ABOUT TWO YEARS AGO. CONCERNED ABOUT THE SAFETY OF THESE TIRES ON OTHER LESS STABLE VEHICLES.*AK
Tires
Filed May 30, 2001TX
THIS IS THE FOURTH TIRE FAILURE OF ORIGINAL EQUIPMENT TIRES SINCE NOV 2000. *AK (DOT NUMBER: VNOP 65C TIRESIZE: LT215/85)
WHEN FILLING FUEL TANK, ONE TANK WOULD OVERFLOW INTO OTHER TANK AND CAUSE A SPILLAGE FROM THAT TANK. FUEL TANK REPAIRED UNDER RECALL A SECOND TIME AS GOODWILL GESTURE. CURRENTLY, SERVICE MANAGER REFUSING TO DO REPAIRS AGAIN. 2ND OWNER. *AK
Electrical System › Wiring › Interior/Under DashFire
Filed Jan 9, 2001WI
SHORTLY AFTER CHANGING BATTERY A FIRE IGNITED IN DASH AREA, CAUSE UNKNOWN. PLEASE GIVE ANY FUTHER DETAILS.*AK
Tires › Tread/Belt
Filed Oct 1, 2000CA
ONE TIRE FAILURE WAS DETECTED AS A LARGE BUBBLE WHERE THE TREAD SEPARATED. THE SECOND WAS A COMPLETE LOSS OF TREAD. (TIRESIZE: LT235/85R1)( DOT NUMBER: TIRE SIZE: LT235/85R1 )
Tires › Tread/Belt
Filed Sep 4, 2000TN
FRONT TIRES PUT ON BY DEALER WHEN I BOUGHT IT 03/03/2000 ON 06/13/2000 RIGHT FRONT TIRE BEGAN TO JUMP UP AND DOWN AND SHAKE THE ENTIRE TRUCK. TIRE STORE STATED PROBLEM WAS DUE TO POSSIBLE BELT SEPERATION WITH-IN THE TIRE. I DID NOT REPLACE THEM WITH THE SAME BRAND TIRES. I HAVE NOT REPLACED THE REAR TIRES YET. FRONT ALIGNMENT WAS CHECK AND DETERMINDED NOT TO BE A FACTOR IN THE TIRE FAILURE.( DOT NUMBER: TIRE SIZE: LT-225-16 )
Engine and Engine Cooling › Engine › Gasoline › Belts and Associated Pulleys
Filed Apr 4, 2000SC
CONSUMER HAD A WATER PUMP PUT ON AT THE DEALERS. ON THE WAY HOME IN THE MIDDLE OF TRAFFIC, FAN BELT CAME OFF, RESULTING IN NO STEERING AND BRAKES. CONSUMER FELT THIS WAS DANGEROUS SINCE VEHICLE LOST FAN BELT FIVE TIMES EARLIER. TOOK VEHICLE TO DEALER, AND HAD TO PAY FOR BELTS. DEALER SAID THERE WAS A PROBLEM WITH BELTS ON THESE VEHICLES. *AK
Power Train › Manual TransmissionFire
Filed Jan 28, 2000OH
TRANSMISSION FIRE, DUE TO POSSIBLE FAILURE. *MJS
Power Train › Clutch Assembly
Filed Sep 29, 1999TN
HAVE HAD TO REPLACE COMPLETE CLUTCH ASSEMBLY THREE TIMES. HAD THE SAME PROBLEM ON ON PREVIOUS FORD TRUCK.
Fuel System, Gasoline › Storage › Tank Assembly
Filed Sep 10, 1999VA
THE VEHICLE HAD BEEN LEAKING FUEL FROM FRONT FUEL TANK. HAD TAKEN VEHICLE TO MECHANIC & WAS INFORMED THE TANK HAD RUSTED & NEEDED REPLACING. *AK
Engine and Engine Cooling › Exhaust System › Emission Control
Filed Jul 29, 1999IA
THERE ARE TWO TANK'S VALVES BETWEEN THE TANKS. WHEN PUTTING GAS INTO ONE TANK, THE GAS WILL GO INTO THE OTHER TANK, CAUSING A LEAK. *AK
Power Train › Axle Assembly › Axle Shaft › Seal
Filed Jul 17, 1999CA
HERS IS A LIST OF ALL FAILURES SINCE NEW. REAR AXEL SEALS, SWAY BAR BRACKETS, CATALYTIC CONVERTER, ECM MODULE, FRONT SEAL ON TRANSMISSION, FUEL PUMP, SPEEDOMETER (TWICE), TURN SIGNAL SWITCH, WATER PUMP AND NOW STARTING TO LEAK AGAIN. *AK
Fuel System, Gasoline › Storage › Tank Assembly › Filler Pipe and CapFire
Filed Mar 29, 1999AZ
TIRE DEBRIS SEVERED THE FILLER NECK REGION OF VEHICLE CAUSING GASOLINE TO SPILL ON ROADWAY AND COME INTO CONTACT WITH THE UNDERCARRIAGE WHICH RESULTED IN FIRE.
Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.
Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.
Most recent recall on file: May 24, 2006. Source: NHTSA Office of Defects Investigation.