2000 Ford F-250

Fatalities reported

Owners filed 326 complaints about this vehicle with federal regulators, most often about the tires. It has been recalled 10 times.

When it fails
020k40k60k90k120k200k
79,000 milesMedian miles at failure

96 complaints record an odometer reading. Failures cluster around 150,000200,000 miles.

What fails
ComponentReportsCrashesFiresInjuries
Tires46
404
Tires › Tread/Belt33
404
Tires › Sidewall19
000
Steering › Hydraulic Power Assist System16
000
Engine and Engine Cooling14
020
Steering10
201
Engine10
000
Air Bags › Frontal10
10010
Service Brakes, Hydraulic › Antilock/Traction Control/Electronic Limited Slip9
100
Electrical System9
010

10 safety recalls

Part 573 reports
Exterior Lighting › Headlights09E025000
Filed May 11, 200942,540 vehiclesDope, Inc.

Defect. DOPE, INC. IS RECALLING 42,540 COMBINATION CORNER AND BUMPER LAMP ASSEMBLIES OF VARIOUS PART NUMBERS SOLD FOR USE AS AFTERMARKET EQUIPMENT FOR VARIOUS PASSENGER VEHICLES. THESE HEADLAMPS FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, "LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT." THESE LAMPS DO NOT CONTAIN THE REQUIRED AMBER SIDE REFLECTORS.

Risk. DECREASED LIGHTING VISIBILITY MAY RESULT IN A VEHICLE CRASH.

Remedy. DOPE, INC. WILL NOTIFY OWNERS AND OFFER A FULL REFUND FOR THE NONCOMPLIANT COMBINATION LAMPS. THE SAFETY RECALL BEGAN ON JULY 28, 2009. OWNERS MAY CONTACT DOPE, INC. AT 1-626-272-1798.

Exterior Lighting09E012000
Filed Apr 7, 200916,270 vehiclesSabersport

Defect. SABERSPORT IS RECALLING 16,270 COMBINATION CORNER AND BUMPER LAMP ASSEMBLIES OF VARIOUS PART NUMBERS SOLD FOR USE AS AFTERMARKET EQUIPMENT FOR VARIOUS PASSENGER VEHICLES. THESE HEADLAMPS FAIL TO CONFORM TO THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, "LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT." THESE LAMPS DO NOT CONTAIN THE REQUIRED AMBER SIDE REFLECTORS.

Risk. DECREASED LIGHTING VISIBILITY MAY RESULT IN A VEHICLE CRASH.

Remedy. SABERSPORT WILL NOTIFY OWNERS AND OFFER A FULL REFUND FOR THE NONCOMPLIANT COMBINATION LAMPS. THE SAFETY RECALL BEGAN ON MAY 11, 2009. OWNERS MAY CONTACT SABERSPORT AT 1-909-598-7589.

Equipment › Electrical07E066000
Filed Aug 28, 2007175 vehiclesCequent Electrical Products

Defect. CERTAIN CEQUENT 90 DEGREE 7-WAY RIGHT ANGLE ADAPTORS SOLD BY DISTRIBUTORS IN TOW PACKAGES FOR AFTERMARKET SALES TO TOW 5TH WHEEL RV TRAVEL TRAILERS. DUE TO INCORRECT WIRING OF THE HARNESS, THE TRAILER LIGHTS MAY NOT OPERATE PROPERLY.

Risk. IF THE TRAILER LIGHTS ARE NOT WORKING PROPERLY, A VEHICLE CRASH CAN OCCUR.

Remedy. ALL OF THE DEFECTIVE TOW PACKAGES ARE STILL AT THE DISTRIBUTOR LEVEL AND HAVE NOT BEEN SOLD TO ANY CONSUMERS.

Vehicle Speed Control06V286000
Filed Aug 1, 20061,200,000 vehiclesFord Motor Company

Defect. ON CERTAIN TRUCKS EQUIPPED WITH SPEED CONTROL, GASOLINE OR NATURAL GAS ENGINES, THE SPEED CONTROL DEACTIVATION SWITCH MAY OVERHEAT.

Risk. OVERHEATING COULD RESULT IN SMOKE OR BURN AND AN UNDERHOOD FIRE.

Remedy. DEALERS WILL INSTALL A FUSED WIRING HARNESS INTO THE SPEED CONTROL SYSTEM FREE OF CHARGE. THE RECALL BEGAN ON AUGUST 7, 2006. OWNERS MAY CONTACT FORD AT 1-866-436-7332. (NOTE: ALSO SEE RECALLS 05V017 AND 05V388)

Exterior Lighting › Headlights06E052000
Filed Jun 12, 200614,616 vehiclesSabry Lee, Inc.

Defect. CERTAIN EAGLE EYES HEADLAMPS, P/NOS. FR208-B101R, FR208-B101L, FR208-B001R, AND FR208-B001L, SOLD FOR USE AS REPLACEMENT EQUIPMENT FOR THE PASSENGER VEHICLES LISTED ABOVE. THESE HEADLAMPS FAIL TO CONFORM TO THE PHOTOMETRIC REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT.

Risk. DECREASED LIGHTING VISIBILITY MAY RESULT IN A VEHICLE CRASH.

Remedy. SABRY LEE WILL NOTIFY OWNERS AND OFFER FULL CREDIT FOR ANY NONCOMPLIANT HEADLAMP. THE RECALL IS EXPECTED TO BEGIN ON JUNE 14, 2006. OWNERS MAY CONTACT SABRY LEE ACCOUNT EXECUTIVE AT 1-866-467-2279.

Exterior Lighting06E049000
Filed May 24, 200627,176 vehiclesCk Motorsport, Inc.

Defect. CERTAIN CK MOTORSPORTS COMBINATION HEADLIGHTS, CLEAR CORNER, BUMPER, AND SIDE MARKER LIGHTS SOLD AS REPLACEMENT LAMPS FOR USE ON THE PASSENGER VEHICLES LISTED ABOVE. SOME COMBINATION LAMPS THAT ARE NOT EQUIPPED WITH AMBER SIDE REFLECTORS FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 108, LAMPS, REFLECTIVE DEVICES, AND ASSOCIATED EQUIPMENT.

Risk. WITHOUT THE AMBER REFLECTORS, THE VEHICLE WILL BE POORLY ILLUMINATED, POSSIBLY RESULTING IN A VEHICLE CRASH WITHOUT WARNING.

Remedy. CK MOTORSPORT WILL NOTIFY OWNERS AND REPLACE THE NONCOMPLIANT LAMPS FREE OF CHARGE. THE RECALL BEGAN ON JULY 1, 2006. OWNERS MAY CONTACT CK MOTORSPORT AT 1-909-610-7211.

Visibility › Windshield Wiper/Washer › Motor01V258000
Filed Aug 8, 20011,083,000 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: PASSENGER CARS, SPORT UTILITY VEHICLES, AND LIGHT AND MEDIUM DUTY PICKUP TRUCKS. A SWITCH LOCATED IN THE PLASTIC COVER OF THE WIPER MOTOR GEAR CASE COULD MALFUNCTION AND OVERHEAT, POTENTIALLY RESULTING IN LOSS OF INTERMITTENT WIPER FUNCTION, LOSS OF WIPER PARK FUNCTION, COMPLETE LOSS OF WIPER FUNCTION, OR IGNITION OF THE PLASTIC COVER MATERIAL. SWITCH MALFUNCTION IS MOST LIKELY TO OCCUR WHEN THE INTERMITTENT SETTING OF THE WIPERS IS BEING USED, OR WHEN SNOW OR ICE OBSTRUCTS THE BLADES FROM RETURNING TO THE "PARKED" POSITION AT THE BOTTOM OF THE WINDSHIELD. THESE VEHICLES WERE BUILT AT THE FOLLOWING ASSEMBLY PLANTS: ATLANTA PLANT FROM 2/11/00 THROUGH 7/31/00; CHICAGO PLANT FROM 2/14/00 THROUGH 8/4/00; KANSAS CITY PLANT FROM 2/26/00 TO 9/4/00; KENTUCKY TRUCK PLANT FROM 2/18/00 TO 8/31/00; MICHIGAN TRUCK PLANT FROM 2/23/00 THROUGH 8/3/00; NORFOLK PLANT FROM 2/21/00 THROUGH 7/27/00; WAYNE STAMPING AND ASSEMBLY PLANT FROM 2/25/00 THROUGH 8/15/00; AND WIXOM PLANT FROM 2/15/00 THROUGH 8/8/00.

Risk. LOSS OF VISIBILITY WHILE DRIVING INCREASES THE RISK OF A CRASH.

Remedy. DEALERS WILL INSPECT THE DATE CODE ON THE WIPER MOTOR. MOTORS BUILT WITH THE SUSPECT TIME FRAME WILL HAVE THE WIPER MOTOR GEAR CASE COVER REPLACED. OWNER NOTIFICATION BEGAN AUGUST 20, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-866-436-7332.

Equipment › Other › Labels00V284000
Filed Sep 21, 20004,500 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: BI-FUEL CNG PICKUP TRUCKS AND BI-FUEL CNG VANS, MODIFIED BY CFI CONTROL SYSTEMS, INC., FAIL TO CONFORM TO THE REQUIREMENTS OF FMVSS NO. 303, "FUEL SYSTEM INTEGRITY OF COMPRESSED NATURAL GAS VEHICLES." THE LABEL AFFIXED TO THE FUEL FILLER DOOR BY THE VEHICLE MODIFIER CONTAINS THE INSPECTION DATE AND EXPIRATION DATE OF THE CNG TANK. HOWEVER, IT DOES NOT CONTAIN THE STATEMENT "SEE INSTRUCTIONS ON THE FUEL CONTAINER FOR INSPECTION AND SERVICE LIFE."

Risk. THESE VEHICLES DO NOT COMPLY WITH THE REQUIREMENTS.

Remedy. OWNERS WILL BE PROVIDED A LABEL WITH THE REQUIRED STATEMENT, ALONG WITH INSTRUCTIONS FOR AFFIXING THE LABEL AT THE FUEL FILLER DOOR. OWNER NOTIFICATION BEGAN NOVEMBER 2, 2000. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.

Fuel System, Gasoline › Storage › Tank Assembly99V311000
Filed Nov 4, 1999107,540 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: PICKUP TRUCKS EQUIPPED WITH GASOLINE ENGINES AND 8 FOOT BOXES, MAY NOT FULLY SATISFY THE REQUIREMENTS OF FMVSS NO. 301, "FUEL SYSTEM INTEGRITY." IN A 30 MPH FRONTAL BARRIER CRASH TEST, A FUEL TANK VAPOR RECOVERY VALVE SEPARATED INTERNALLY. DURING THE SUBSEQUENT STATIC ROLLOVER TEST, FUEL SPILLAGE EXCEEDED THE SPECIFIED RATE.

Risk. FUEL LEAKAGE, IN THE PRESENCE OF AN IGNITION SOURCE, COULD RESULT IN A FIRE.

Remedy. DEALERS WILL INSTALL A STOP PLATE ASSEMBLY ON THE VEHICLE FRAME TO PREVENT RECOVERY VALVE CONTACT WITH A FRAME CROSSMEMBER DURING THE IMPACT SEQUENCE.

Fuel System, Gasoline › Storage › Tank Assembly99V219000
Filed Aug 12, 1999245,300 vehiclesFord Motor Company

Defect. VEHICLE DESCRIPTION: GASOLINE AND DIESEL ENGINE PICKUP TRUCKS EQUIPPED WITH 8 FOOT BEDS, DO NOT FULLY SATISFY THE REQUIREMENTS OF FMVSS NO. 301, "FUEL SYSTEM INTEGRITY." THE FUEL TANK FRONT STRAP ISOLATOR MAY NOT BE PROPERLY POSITIONED WHICH COULD RESULT IN THE STRAP CUTTING THE TANK DURING A 30 MPH FRONT BARRIER TEST, RESULTING IN FUEL SPILLAGE.

Risk. DURING THE SUBSEQUENT STATIC ROLLOVER TEST, FUEL SPILLAGE EXCEEDED THE SPECIFIED RATE, INCREASING THE RISK OF A FIRE.

Remedy. DEALERS WILL REPOSITION THE FRONT STRAP ISOLATOR.

What owners reported

Newest filings
Electrical System › Instrument Panel › Speedometer/Odometer
Filed Feb 12, 2026176,369 milesME

Odometer Fraud. The contact purchased a 1999 N/A Ford F-250. The contact discovered a mileage discrepancy after the purchase. The vehicle was a private sale. At the time of purchase, the vehicle mileage was 176,369. The contact stated that the odometer was inoperable. The contact stated that the odometer only operated while the 4WD feature was activated. Upon further investigation, the contact became aware that when the previous owner purchased the vehicle in 2023, the mileage was 167,697. The correct odometer reading was unknown.

Fuel System, Gasoline
Filed Sep 17, 2025155,000 milesCA

The contact owns a 1993 N/A Ford F-250. The contact received notification of NHTSA Campaign Number: 00V424000 (FUEL SYSTEM, GASOLINE). The contact stated that fuel spewed out of the rear tank filler neck. The vehicle was taken to the dealer; however, the dealer refused to perform the recall repair. The contact was informed that the recall repair pertained only to the chassis and not light-duty trucks. The vehicle was not repaired. The manufacturer was not made aware of the failure. The failure mileage was approximately 155,000.

Vehicle Speed Control
Filed Aug 13, 2025CA

The contact owns a 1994 Ford F-250. The contact stated that while renewing the registration, the contact was informed of an open, unrepaired recall associated with the VIN. The unrepaired open recall was NHTSA Campaign Number: 09V399000 (Vehicle Speed Control). The vehicle was taken to the dealer; however, the dealer declined to perform the recall repair because the VIN was not in the Manufacturer’s Database. The manufacturer was made aware of the failure but provided no assistance. The manufacturer located the VIN information in the database and the contact was referred to the dealer for assistance. The contact had not experienced a failure.

Unknown or Other
Filed Jun 30, 2025AK

Your records are inaccurate, the issues have been repaired by me because Ford refused to comply. update your records

Electrical System
Filed Oct 18, 2022240,000 milesMT

The contact owns a 2000 Ford F-250. The contact stated that while standing next to the vehicle a burning odor was present coming from under the hood. Upon inspection of the vehicle, it was discovered that several wiring harnesses were saturated with leaking brake fluid. The contact was concerned that the saturated wiring harnessed had caused electrical failures within the vehicle. The cause of the failure was not yet determined. The local dealer was notified of the failure. The manufacturer was not yet contacted. The failure mileage was 240,000.

Tires › Tread/BeltCrash
Filed May 9, 2022TN

Left front tire blew without warning, lost control of truck and trailer and crossed the median into oncoming interstate traffic. Stearing link on truck broke, not sure when. Truck and trailer were totaled. LEFT REAR TIRE BLEW WHILE PARKED A COUPLE OF MONTHS LATER. No visible defects. I have attached two pictures of the left front tire taken at the scene of the accident and three pictures of the left rear tire taken as it failed in two stages, first a bulge in the tread, followed a few weeks later by a zipper-like sidewall separation. Tires were less than 10 years old when they failed. I still have the tires as well as the other two matching tires from the set. The accident occurred in Bath NY. Michelin LT235/85R16

Latches/Locks/Linkages
Filed Sep 15, 2021GA

The contact owns a 2000 Ford F-250. The contact stated that the passenger’s side and driver’s side rear door locking mechanism was faulty and the doors could no longer be opened. The cause of the failure was not determined. The local dealer and manufacturer were not notified of the failure. The VIN was not available. The failure mileage was unknown.

Power Train1 injured
Filed Feb 3, 2021295,000 milesMD

TL* THE CONTACT OWNS A 2000 FORD F-250. THE CONTACT STATED THAT WHILE ATTEMPTING TO ENTER HIS VEHICLE, THE GEAR SHIFTER INADVERTENTLY SHIFTED INTO REVERSE CAUSING THE DOOR TO KNOCK THE CONTACT DOWN TO THE GROUND WHERE THE CONTACT WAS RAN OVER BY THE VEHICLE. THE CONTACT SUFFERED BROKEN RIBS, TWO FRACTURED VERTEBRAE IN THE NECK, A PARTIALLY SEVERED RIGHT EAR, AND AN UNSTATED INJURY TO HIS LEGS. THE VEHICLE THEN PROCEEDED TO ROLL DOWN A SLIGHT HILL AND CAME TO A STOP AFTER CRASHING INTO A PARKED VEHICLE. MEDICAL ASSISTANCE ARRIVED TO THE SCENE AND THE AMBULANCE TOOK THE CONTACT TO THE HOSPITAL FOR MEDICAL TREATMENT TO HIS INJURIES. THE CONTACT WANTED TO STAY THAT HE WAS ON LIFE SUPPORT FOR TWO WEEKS AND ON A FEEDING TUBE FOR A FEW WEEKS. THERE WAS NO ONE ELSE INJURED. A POLICE REPORT WAS FILED. THE VEHICLE WAS TOWED TO AN IMPOUND LOT AND LATER SENT TO AN INDEPENDENT MECHANIC. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS 295,000.

Structure › Body
Filed Dec 3, 202020,000 milesCA

WE JUST BOUGHT THIS TRUCK AND THE OLD MAN THAT OWNED IT HAS USED A BUNGEE CORD TO KEEP IT SHUT BUT WE PREFER NOT TO DO THAT SO I'M LETTING THE PROPER AUTHORITIES BE AWARE THAT THE DRIVER'S DOOR LATCH WON'T STAY SHUT, SOMETHING WRONG WITH THE LATCH, THE DOOR OPENS WHEN DRIVING.

Steering
Filed Nov 6, 2019268,000 milesIN

WHEN DRIVING AND HITTING A BUMP ESPECIALLY IN A TURN, THE FRONT WHEELS SHUTTER VIOLENTLY.

Vehicle Speed Control
Filed Oct 11, 2019226,000 milesND

MY CRUISE CONTROL WENT OUT, I WAS RESEARCHING ONLINE WHAT PARTS MAY HAVE GONE OUT WHEN I SEEN A RECALL DONE FOR CRUISE CONTROLS COVERING FORD VEHICLES INCLUDING THE DIESEL OF MY TRUCK AND YEAR. WHEN I CALL TODAY I WAS TOLD MY VEHICLE WAS NOT COVERED I DO NOT SEE HOW ALL THESE OTHER VEHICLES ARE COVERED DID INCLUDE AT THE DIESEL AND THE YEAR OF MY TRUCK AND NOW THEY SAY IT'S NOT COVERED. THE CRUISE CONTROL STOPPED WORKING ON MY WAY TO WORK OCTOBER 7TH.

Electrical System
Filed Sep 17, 2019140,000 milesTX

TAIL LIGHT BULB SOCKET BURNT. NOTICED THAT BULB ACTS LIKE IT'S BLOWN BUT RESEATING ALLOWS IT TO FUNCTION AGAIN. THIS HAPPENS ABOUT ONCE A MONTH. NO FUSES ARE TRIPPED WHICH IS ODD. HOWEVER THE FIRST TIME I CHECKED THIS I NOTICED THE SOCKET WAS SCORCHED YET WIRING LOOKS OK. I ASSUMED IT WAS JUST MY VEHICLE BUT SINCE HAVE HEARD SAME REPORT FROM OTHERS ON THEIR TRUCKS AND CARS. THERE IS NO INDICATION OF DANGER UNTIL YOU REMOVE TAIL LIGHT TO CHECK BULB.

Structure › Body
Filed Jul 7, 2019214,198 milesIN

TRUCK HAD BEEN PARKED ALL AFTERNOON AT WORK. UPON LEAVING WORK THERE WAS A SUDDEN LOUD NOISE THAT WENT ON FOR A FEW SECONDS AND THEN STOPPED. IMMEDIATELY I THOUGHT I HAD HIT SOMETHING BUT ONCE THE VEHICAL WAS STOPPED I SAW THAT THE UNIROYAL LIBERATOR A/T TIRE HAD BEEN THE ISSUE. IT HAD TREAD SEPERATION AND HAD DESTROYED THE BED OF MY TRUCK WHEN IT CAME APART.

Power Train › Clutch Assembly › Pedal/Hand Lever(motorcycle)
Filed Jun 18, 2019NC

2000 FORD F250. CONSUMER WRITES IN REGARDS TO DEFECTIVE CLUTCH PEDAL. *LD THE CONSUMER STATED THE CONNECTION BETWEEN THE CLUTCH PEDAL AND THE LINKAGE FAILED AT LEAST 4 TIMES *JS

Structure › Body
Filed Sep 25, 2018IL

BRACKETS HOLDING FUEL TANKS HAVE CORRODED ALLOWING THE FUEL TANK TO DROP. I NOTICED IT WHEN I PARKED MY TRUCK IN THE DRIVEWAY. I HAVE SINCE PUT A CHAIN AROUND TO TRY TO PREVENT IT FROM DROPPING ENTIRELY AND EXPLODING.

Steering
Filed Jan 10, 2018223,888 milesCA

WE HAD JUST HAD NEW FIRESTONE TRANSFORCE HT TIRES PUT ON OUR TRUCK. APPROXIMATELY FOUR MONTHS LATER, AS WE ARE TRAVELING DOWN THE HIGHWAY AT 65 MPH, WE FELT A SERIOUS VIBRATION IN THE LEFT REAR TIRE. WE SLOWED DOWN TO 60 MPH & THAT'S WHEN THE TIRE BLEW OUT. WE PULLED TO THE SHOULDER OF THE HIGHWAY TO INSPECT & THE TIRE BLEW OUT THE SIDEWALL. WE DID NOT HIT ANYTHING & NO ROAD HAZARD CAUSED THIS DAMAGE. WE SIMPLY FELT AS A SERIOUS VIBRATION & WITHIN A HALF A MILE OR MILE IT BLEW OUT. THE SHOP WHERE WE PURCHASED THE TIRES CHARGED US FOR ANOTHER TIRE. THIS SHOULD HAVE BEEN COVERED BY WARRANTY BUT WE WENT AHEAD AND PAID FOR IT BECAUSE WE NEEDED THE VEHICLE FOR WORK. IT CONTINUED TO HAVE SEVERE VIBRATIONS WHICH CAUSE DIFFICULTY STEERING THE VEHICLE IN ACCELERATION & IN BRAKING. SO WE HAD EVERYTHING REPLACED ON THE FRONT END. AFTER THIS, THE TRUCK STILL FELT UNSTABLE...THE VIBRATION WAS STILL THERE AND IT WAS STILL DIFFICULT TO STEER.. IT ALSO HAD A TENDENCY TO PULL FROM ONE SIDE TO THE OTHER & AT ALL TIMES & MY AIR PRESSURE WAS AT SPEC. THEN JUST RECENTLY, WE NOTICE THAT ALL THE TIRES, INCLUDING THE ONE THAT WE HAD REPLACED FROM THE BLOWOUT, WERE COMING APART ON THE SIDE WALLS. THERE WERE CRACKS ALL AROUND THE SIDEWALL OF EVERY SINGLE TIRE. THIS CAUSED QUITE AN ALARM TO US AS WE HAD BEEN DRIVING THIS TRUCK & COULD HAVE BEEN SERIOUSLY INJURED OR KILLED HAD WE NOT NOTICE THIS FLAW! THERE'S A PROBLEM WITH THESE TIRES AND IT IS SERIOUS! THERE'S ALSO ALSO A PROBLEM WITH SOME OF YOUR DEA

Engine
Filed Aug 17, 201786,009 milesLA

WENT TO START ENGINE IN THE TRUCK AFTER SETTING OVER NIGHT UNDER MY CARPORT AND SPARK PLUG BLEW OUT OF THE HEAD . THIS TRUCK HAS A 5.4 LITER V8

Tires › Tread/Belt
Filed Jun 9, 2017FL

TL* THE CONTACT OWNS A 2000 FORD F-250 EQUIPPED WITH CONTINENTAL GENERAL (NA) TIRES, SIZE: 265/75/R16 (NA). WHILE DRIVING 60 MPH, THE TREAD SEPARATED FROM THE REAR TIRE. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC WHO CONFIRMED THAT THE TREAD SEPARATED FROM THE PASSENGER SIDE FRONT AND REAR TIRE. THE TIRES WERE REPLACED. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE VEHICLE FAILURE MILEAGE, TIRE FAILURE MILEAGE, AND VIN WERE UNAVAILABLE.

Unknown or OtherFire
Filed May 4, 2017160,000 milesGA

EJECTED SPARK PLUG RUPTURING THE FUEL RAIL CATCHING THE TRUCK ON FIRE, BURNING IT TO A CRISP. HAPPENED 4 TIMES, (EJECTING THE PLUG) THE FIRST TIME THE FORD DEALER REPAIRED IT. WE WERE DRIVING IT DOWN THE ROAD HEARD A BANG THAN A HISS OF THE FUEL LEAKING GOT THE TRUCK STOPPED AND JUST GOT OUT IN TIME. FULL FLAMES IN LESS THAN 2 MINUTES.

Engine
Filed Feb 16, 2017265,000 milesNC

I HAVE HAD THREE DIFFERENT OCCASIONS WHERE THE SPARK PLUG HAS BLOWN OUT WHILE I WAS DRIVING TO AND FROM WORK AND TWO OF THE THREE TIMES I ALMOST HIT ANOTHER VEHICLE.WE FIXED THEM WITH NEW PARTS FROM AUTO STORE BUT WAS REMINDED THAT THE REPAIR IS ONLY TEMPORARY.TWO OR THE THREE TIMES I WAS ON A HIGHWAY IN BUSY TRAFFIC AND THE OTHER TIME I WAS ON A RURAL ROAD.

20 of 326 complaints, reproduced as filed.

Across model years

Worst on record: 1999
YearComplaintsRecallsFiresDeathsAssessment
2014142010Routine
201395010Routine
2012266150Above average
2011248230Above average
201073020Routine
200954110Routine
2008195841Fatalities reported
200760700Routine
2006221750Above average
2005144530Routine
2004154740Routine
2003116781Fatalities reported
2002156791Fatalities reported
20012209244Fatalities reported
2000 — this page32610147Fatalities reported
199958119132Fatalities reported
199856910Routine
199730414190Above average
19961765250High concern
19951844170Routine
199412310230High concern
1993130940Routine
1992119761Fatalities reported
1991107790Routine
19901117140Routine

Compare every F-250 year →

Reading this record

7 deaths reported in complaints filed with NHTSA.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.

Most recent recall on file: May 11, 2009. Source: NHTSA Office of Defects Investigation.