1998 Ford Mustang GT

Routine

Owners filed 53 complaints about this vehicle with federal regulators, most often about the engine and engine cooling › exhaust system › manifold/header/muffler/tail pipe. No safety recall has been issued.

When it fails
020k40k60k90k120k200k
82,000 milesMedian miles at failure

38 complaints record an odometer reading. Failures cluster around 60,00075,000 miles.

What fails
ComponentReportsCrashesFiresInjuries
Engine and Engine Cooling › Exhaust System › Manifold/Header/Muffler/Tail Pipe14
111
Engine and Engine Cooling › Engine12
010
Engine and Engine Cooling › Cooling System9
000
Engine and Engine Cooling8
000
Tires › Sidewall1
100
Suspension1
000
Structure1
000
Seat Belts › Front › Retractor1
000
Seat Belts1
000
Parking Brake › Conventional1
000

What owners reported

Newest filings
Seat Belts
Filed Sep 9, 2013150,000 milesVA

PASSENGER SEAT BELT FAILING EXTENDED AND LOCKED. UNUSABLE *TR

Engine and Engine Cooling
Filed Feb 2, 2012NV

THE PLASTIC INTAKE MANIFOLD CRACKED AND LEAKED COOLANT ONTO THE ENGINE AND OTHER RELATED COMPONENTS. CAR DIED ON FREEWAY. THE PLASTIC INTAKE MANIFOLD CRACKS. THE COOLANT WILL LEAK ONTO THE TOP OF THE BLOCK AND THEN DOWN THE BACK OF THE ENGINE. THIS INTAKE DESIGN IS A KNOWN DEFECT BY FORD. BELOW IS AN "OWNER NOTIFICATION LETTER" FROM FORD: 97M91 APRIL, 1999 FORD MOTOR COMPANY IS PROVIDING A NO-CHARGE SERVICE PROGRAM NUMBER 97M91, TO OWNERS OF CERTAIN 1996 THROUGH 1998 CROWN VICTORIA TAXI, TOWN CAR LIMO PREP & DELIVERY PACKAGE, 1996 AND 1997 THUNDERBIRD, COUGAR AND MUSTANG VEHICLES EQUIPPED WITH 4.6L SOHC ENGINES. THIS SERVICE PROGRAM PROVIDES ADDITIONAL COVERAGE FOR THE INTAKE MANIFOLD. REASON FOR THIS PROGRAM FATIGUE CRACKS MAY DEVELOP IN SOME OF THE COMPOSITE INTAKE MANIFOLDS USED ON THE 4.6L SOHC ENGINES INSTALLED IN THE AFFECTED CARS. THIS CONDITION MAY RESULT IN ENGINE COOLANT LEAKAGE WHICH, IF NOT DETECTED OR IGNORED, WILL CAUSE ENGINE OVERHEATING. COMPLETE LOSS OF COOLANT MAY RESULT IN ENGINE DAMAGE OR ENGINE FAILURE. WHAT WE WILL DO IF THE ENGINE OF YOUR CAR SHOULD DEVELOP A COOLANT LEAK AT THE INTAKE MANIFOLD CROSS OVER COOLANT PASSAGE, LOCATED DIRECTLY BEHIND THE ALTERNATOR, YOUR DEALER WILL VERIFY THE CONDITION. IF THE COOLANT LEAKAGE IS FROM THE LOCATION DESCRIBED ABOVE, YOUR DEALER WILL REPLACE THE ENGINE INTAKE MANIFOLD ASSEMBLY FREE OF CHARGE. THIS NO CHARGE COVERAGE IS AVAILABLE FOR 7 YEARS FROM THE VEHICLE'S WARRANTY START DATE (NO MILEAGE LIMITATION) AND IS A

Engine and Engine Cooling › Engine
Filed Sep 3, 2010138,000 milesIL

WHILE DRIVING ON THE INTERSTATE AT 65MPH, THE INTAKE MANIFOLD CRACKED, SPRAYING COOLANT AND STEAM FROM THE HOT ENGINE OUT THE BACK OF THE HOOD. THIS COVERED THE WINDSHIELD, CAUSING ME TO LOSE ALL VISIBILITY. THIS IS VERY DANGEROUS, HAD THERE BEEN SOMETHING IN FRONT OF ME, I WOULD HAVE CAUSED AN ACCIDENT. I SEE THAT THERE ARE NUMEROUS RECALLS FOR THE SAME PART/ENGINE ON OTHER YEARS AND VEHICLES. THE DEALER ALSO REPLACES IT, WITH AN UPDATED VERSION TO AVOID FAILURE, AT A COST OF $900.00. IF IT IS RECALLED ON ONE CAR, WHY NOT THE REST. IT IS THE SAME PART NUMBER AND THE SAME ENGINE, IT SHOULDN'T MATTER WHAT MODEL VEHICLE IT IS IN. SOMEDAY THERE WILL BE A TERRIBLE ACCIDENT DUE TO THIS. *TR

Engine and Engine Cooling › Engine
Filed Nov 29, 200768,700 milesWI

INTAKE MANIFOLD FAILURE ON 1998 FORD MUSTANG GT / 4.6L / 2V PER CLASS ACTION SUIT US DISTRICT COURT / NORTHERN DISTRICT OF CALIFORNIA. *TR

Engine and Engine Cooling › EngineFire
Filed Nov 27, 2007140,000 milesFL

TL*THE CONTACT OWNS A 1998 FORD MUSTANG GT. APPROXIMATELY FIFTEEN MINUTES AFTER PARKING AND EXITING THE VEHICLE, THE ENGINE COMPARTMENT BECAME ENGULFED IN FLAMES. THE VEHICLE WAS DESTROYED. THERE WAS DAMAGE TO ANOTHER VEHICLE AND TO A NEIGHBORING HOME; HOWEVER, THE CONTACT DID NOT KNOW THE EXTENT OF THE DAMAGE. A FIRE REPORT WAS FILED. THE VIN AND PURCHASE DATE WERE UNKNOWN. THE CURRENT AND FAILURE MILEAGES WERE 140,000. UPDATED 03-04-08 *BF UPDATED 03/04/08 *TR

Electrical System › Wiring › Front UnderhoodFire1 injured
Filed Oct 9, 200747,000 milesWA

MY COMPLAINT IS IN REGARDS TO THE 05N04 RECALL ON MY MOTHERS 1998 FORD MUSTANG. LAST FRIDAY MY 80 YEAR MOTHER GOT LOST AND I SENT MY NIECE TO PICK HER UP, AND ON THEIR WAY HOME THE CAR CAUGHT FIRE AND DIED, MY NIECE THINKING QUICKLY TURNED THE CAR INTO FIRE STATION AND WAS ABLE TO GET HELP FAST. I THANK GOD MY MOTHER WAS NOT DRIVING WHEN THE HOOD FIRE STARTED, SHE WOULD HAVE WRECKED FOR SURE. I THEN HAD THE CAR TOWED TO WALT'S AUTO CARE THE NEXT DAY, WHICH WAS ON SATURDAY AND TESTS WERE RUN TO FIND THE REASON WHY THE CAR CAUGHT ON FIRE WITHOUT ANY TYPE OF PRIOR WARNING FROM THE CAR OBC. IT WAS NOT UNTIL THEN WE WERE INFORMED OF THE RECALL NOTICE AND TOLD THAT IT WAS COVERED UNDER THE RECALL NOTICE. HOWEVER, WE RECEIVED A CALL MONDAY FROM WALT'S STATING THAT THEY COULD NOT DO THE WORK AND THAT THEY HAD THE CAR TOWED TO ANOTHER SERVICE STATION NAMED RENTON AUTO REPAIR. I WAS CONTACTED BY THEM TO FIND OUT WHO WOULD BE PAYING FOR THE SERVICE REPAIRS AND IT WAS THEN I INFORMED HIM WITH THE SAME INFORMATION THAT WAS RELATED TO ME BY THE FIRST SERVICE STATION. UPON LOOKING IT UP, I WAS THEN TOLD THAT THEY COULD NOT DO THE WORK AND I WOULD HAVE TO TAKE IT TO A AUTHORIZED FORD REPAIR CENTER. I THEN CONTACTED SOUND FORD, THE PLACE OF PURCHASE AND WAS TOLD THAT IT WAS TOO LATE TO MAKE A CLAIM FOR REPAIRS, BECAUSE THE CAMPAIGN HAD CLOSED FOR OUR CAR YEAR IN 2006 AND IT WOULD HAVE HAD TO FAIL BEFORE THAT TIME. I THEN EXPLAINED THE CAR WAS BROUGHT IN FOR REPAIRS IN 2004 AND WE WERE NEVER I

Engine and Engine Cooling
Filed Sep 29, 200720 milesCA

SPARK PLUG SHOT OUT OF MY MUSTANG ENGINE THE DEALER SAID THEY FIXED THE PROBLEM BUT IT HAPPENED AGAIN. I PAID FOR THE REPAIRS TWICE AND THEN AGAIN FOR A 3RD TIME. IT SHOT OUT ON THE ROAD AND COULD HAVE CAUSED AN ACCIDENT. *JB

Engine and Engine Cooling › Exhaust System › Manifold/Header/Muffler/Tail Pipe
Filed Apr 23, 200794,000 milesPA

TL* THE CONTACT OWNS A 1998 FORD MUSTANG. WHILE DRIVING 60 MPH THE CONTACT SMELLED ANTI- FREEZE. THE CONTACT DID NOT REMEMBER IF THE AIR CONDITIONER WAS ON OR NOT. AFTER REMOVING THE THERMOSTAT SHE NOTICED THAT THE INTAKE MANIFOLD WAS CRACKED. THE VEHICLE HAS NOT BEEN DIAGNOSED BY THE DEALER. THE MANUFACTURER STATED THAT THERE WAS NOTHING THAT THEY COULD DO. THE FAILURE MILEAGE WAS 94,000, AND THE CURRENT MILEAGE WAS 95,427. *AK

Engine and Engine Cooling › Cooling System
Filed Apr 19, 2007OH

OWNED CAR FOR OVER 5 YRS. ALMOST PAID OFF. DISCOVERED COOLANT LEAK. PUT IN NEW WATER PUMP, NEW PULLEYS, NEW THERMOSTAT, NEW THERMOSTAT HOUSING, NEW HOSES. ONLY TO DISCOVER THE JUNK PLASTIC INTAKE MANIFOLD IS CRACKED. NOW I FOUND OUT BY SEARCHING THE INTERNET THAT THIS IS A COMMON PROBLEM ON MY YEAR OF CAR. FORD IS AWARE OF SAID PROBLEM DUE TO CRAPPY ENGINEERING AND REFUSES TO MAKE IT RIGHT WITH CONSUMERS. THEY MADE IT RIGHT WITH THE FLEET CARS THAT ARE 1998'S AND CARS OTHER THAN MY YEAR. *TR

Engine and Engine Cooling › Cooling System
Filed Jan 28, 2007100,000 milesMI

1) PLASTIC MANIFOLD STARTED LEAKING. NO WARNING. 2) DUMPED ALL COOLANT ON MOTOR AND LEFT ME STRANDED. 3) WILL HAVE TO REPLACE AT A COST OF OVER $900. *NM

Engine and Engine Cooling › Engine › Gasoline
Filed Nov 9, 200661,250 milesFL

CRACKED COMPOSITE INTAKE MANIFOLD COOLANT CROSSOVER RESULTING IN COOLANT LEAK. MANIFOLD BEING REPLACED WITH NEW ALUMINUM MANIFOLD. I SUBSEQUENTLY BECAME AWARE OF SETTLEMENT IN CHAMBERLAN V. FORD. I NEVER RECEIVED NOTIFICATION OF SETTLEMENT AND MY VEHICLE WAS PAST THE 7 YEAR LIMIT AT THE TIME OF THE SETTLEMENT. I FEEL THAT FORD SHOULD EXTEND COVERAGE. *JB

Engine and Engine Cooling
Filed Oct 19, 2006MA

LAST YEAR I RECEIVED NOTIFICATION OF A CLASS ACTION SETTLEMENT. I HEARD NOTHING ELSE AFTERWARD, AND HAVE ONLY JUST REALIZED THAT I MISSED THE MARCH 16, 2006 DEADLINE. IS THERE ANYTHING THAT PEOPLE LIKE MYSELF CAN DO IN THIS INSTANCE? *NM

Engine and Engine Cooling › Cooling System
Filed Oct 17, 200660,000 milesMD

1998 FORD MUSTANG GT INTAKE MANIFOLD CRACKED AND LEAKING ANTIFREEZE. MISSED THE SILENT RECALL BY 6 MONTHS. *NM

Engine and Engine Cooling › Engine
Filed Oct 15, 200682,000 milesDE

FORD RECALL PLASTIC INTAKE MANIFOLDS.I HAVE PURCHASED A 1998 MUSTANG FROM A NON FORD DEALER THERE IS A DEFINITE LEAKING INTAKE ON THIS MOTOR,I HAVE CONTACTED A FORD DEALER IN MY AREA THEY SAID THE RECALL TIME HAS EXPIRED.THE PLACE OF PURCHASE AND MY SELF NEW OF NO RECALL UNTILL I STARTED LOOKING ON THE INTERNET,AND STARTED TO KEEP ADDING ANTIFREEZE TO THE SYSTEM,YOU CAN SEE THE LEAKING INTAKE,

Engine and Engine Cooling
Filed Aug 22, 200689,500 milesAZ

MY 98 GT MUSTANG PLASTIC RADIATOR INTAKE HAS RUPTURED AT 89,000 MILES. IT SEEMS ALL OF FORD'S EQUIPPED WITH FORD'S 4.6L V-8 CONTAIN AN INTAKE MANIFOLD THAT IS PRONE TO FAILURE. DUE TO ORIGINAL DESIGN, THIS PART HAS A TENDENCY TO CRACK RESULTING IN SOMETIMES OVER HEATING, ENGINE FAILURE AND WORSE CASE DAMAGE TO OTHER PARTS OF THE CAR'S ENGINE. FORD RECOGNIZES THIS PROBLEM BUT WILL NOT RECALL MOST CARS OTHER THAN FLEET VEHICLES AND THOSE LISTED IN THE TSB #97M91. 1. 1998 MUSTANG WAS OVERHEATING WHILE DRIVING DOWN THE HIGHWAY. 2. WHEN CAR WAS TAKEN TO A REPAIR SHOP THE MECHANIC NOTICED A CRACK IN THE MANIFOLD AND ADVISED ME TO TAKE IT TO MY LOCAL DEALER. IT WAS BROUGHT TO MY ATTENTION THAT IF THIS PART WAS NOT CORRECTED ENGINE FAILURE COULD OCCUR DUE TO COOLANT LOSS RESULTING IN SEVERE DAMAGE. 3. CAR WAS TAKEN TO LOCAL FORD DEALERSHIP AND I GAVE THEM THE TSB #97M91 AND TOLD THEM TO REPLACE THE PART. 1998 MUSTANG WAS NOT LISTED AND THE CAR AND CAN'T BE FIXED AT DEALER'S COST ONLY CONSUMER'S. I CALLED FORD MOTOR COMPANY AND HAVE NOT HAD ANY LUCK TALKING TO CUSTOMER SERVICE ABOUT THIS PROBLEM. FORD OWNERS BE AWARE OF THIS PROBLEM.*AK

Engine and Engine Cooling › Cooling System
Filed May 12, 200694,000 milesKY

FORD MOTOR COMPANY SETTLED THE LAWSUIT WITH THE DEFECTIVE INTAKE MANIFOLD THAT WAS TO CRACKING BUT DID NOT INCLUDE ALL VEHICLES AND I HAPPEN TO BE ONE OF THEM. I SHOULD NOT HAVE TO PAY FOR THEIR DEFECTIVE PARTS. THEY EXTENDED THE WARRANTIES OR SEVEN YEARS BUT ONLY AFTER A CERTAIN DATE AND MANY FORD OWNERS WERE LEFT OUT IN THE COLD. THEY SHOULD REPLACE ALL OF THEM NO MATTER WHAT!! *NM

Engine and Engine Cooling › Engine
Filed Sep 22, 200596,203 milesTX

AFTER SERVICE OF MY 4.6 MUSTANG GT, MY CAR BEGAN MISSING AND I HAD THE DIAGNOSTIC COMPLETE IT REPORTED A MISFIRE ON PLUG 7 & 8, SO I HAD THE PLUGS REPLACED. DURING THE REPLACEMENT, I SAW COOLANT UNDER BOTH THE 7 & 8 PLUG. THE MISFIRE CONTINUES, AND I TOOK IT TO THE DEALER THEY TOLD ME THE INTAKE MANIFOLD HAD FAILED AND THAT THERE IS NO REMEDY FOR THE CONSUMER EVEN THOUGH FORD IS AWARE OF THE PROBLEM AND HAS A KIT TO SELL TO THE CONSUMER FOR 900+ DOLLARS. FLEET CARS TAXI, CROWN VIC'S USED BY SHERIFF DEPARTMENTS WERE CLEARED FOR REPLACEMENT, BUT NO THE CONSUMER CIVILIAN. WHAT SENSE DOES THAT MAKE? IF THE ENGINEERING IS BAD, AND IT IS, THE REPLACEMENT SHOULD BE FOR ALL OWNERS OF THE 4.6 LITER ENGINE. HOW IS THE SEGREGATION OF FLEET CARS FROM PERSONAL USE VEHICLES LEGAL IN THIS COUNTRY? EVERYONE WHO OWNS THESE DEFECTIVE VEHICLES SHOULD HAVE A REPLACEMENT MADE AVAILABLE REGARDLESS OF WHEN THE FAILURE OCCURRED, AND WHAT OTHER DAMAGE CAN I EXPECT TO FIND? WILL THIS HAVE A DAISY CHAIN OF FAILURES DUE TO THE BAD DESIGN? I UNDERSTAND THE COST TO REPLACE WILL BE $1,200.00 + WITH THE DEALERSHIP ESTIMATE PARTS AND LABOR. *JB

Interior Lighting
Filed Aug 30, 200547,000 milesWI

I DO NOT KNOW IF THIS IS A SAFETY HAZARD. I HOPE YOU WILL LET ME KNOW. I OWN A 1998 FORD MUSTANG GT. IT HAS 48,620 MILES ON IT. ABOUT A YEAR AGO, THE CRUISE CONTROL AND INSIDE LIGHTS STOPPED WORKING. I TOOK IT IN TO A FORD DEALERSHIP. THEY TOLD ME IT WAS SOME KIND OF SENSOR OR SOMETHING LIKE THAT. I DO NOT REMEMBER SPECIFICS. THEY TOLD ME IT WOULD BE ABOUT $500.00 PLUS TO FIX IT. I COULD NOT AFFORD TO FIX. LAST MONTH THE ABS LIGHT CAME ON IN THE CAR. I TOOK IT IN LAST WEEK AND THEY TOLD ME THE HYDRAULIC CONTROL UNIT WAS BAD. IT WOULD BE $992.00 PLUS TO FIX IT. I SPENT $115.00 JUST SO THEY COULD TELL ME THIS. I AM FINANCIALLY STRAPPED, I DO NOT HAVE THIS KIND OF MONEY. THE CAR IS IN MINT CONDITION. YES, IT IS ABOUT 8 YEARS OLD BUT, AS YOU CAN SEE BY THE MILES IT HAS HARDLY BEEN DRIVEN. FORD DOESN'T SEEM TO WANT TO DO ANYTHING ABOUT IT. I DO NOT THINK ALL OF THESE SENSORS AND OTHER THINGS SHOULD BE GOING WRONG WITH IT. I FEEL LIKE THIS IS A MANUFACTURING ERROR AND PROBLEMS ON FORDS END. I THINK THEY SHOULD BE FIXING THESE THINGS. I COULD SEE IF MY CARD HAD MORE MILES ON IT AND I HAD THESE PROBLEMS BUT, NOT AT 48,620 MILES. I DO NOT KNOW WHAT CAN HAPPEN IF THE ABS UNIT IS NOT REPLACED. THE FORD DEALERSHIP WOULD NOT GO INTO DETAILS. SO, COULD YOU PLEASE TELL ME WHAT YOU CAN DO FOR ME. *NM

Engine and Engine Cooling › Exhaust System › Manifold/Header/Muffler/Tail PipeCrashFire1 injured
Filed Jun 14, 2005CA

INTAKE MANIFOLD DEFECTS.. IT'S MADE FROM PLASTIC AND IT CAN NOT WITHSTAND ALL THE PRESSORE AND HEAT THAT IT WILL CRACK VERY EALRY AND CAUSE COOLING FLUID TO LEAK , AND WITH ALL THAT STEM COMING FROM THE HOOD IT WILL BE SO HARD TO SEE THE ROAD AND WILL CAUSE A FIRE FROM THE ELECTRIC SYSTEM SHORTING OUT FROM THE FLUID.

Engine and Engine Cooling › Exhaust System › Manifold/Header/Muffler/Tail Pipe
Filed May 27, 200579,000 milesCA

INTAKE MANIFOLD CRACKED UNDER NORMAL OPERATION WITH NO REAL REASON AS TO IT'S FAILURE OTHER THAN STRUCTURAL FLAWS IN IT'S ORIGINAL DESIGN.

20 of 53 complaints, reproduced as filed.

Across model years

Worst on record: 2005
YearComplaintsRecallsFiresDeathsAssessment
2006151110Routine
2005163110Routine
200414000Routine
200351000Routine
200248010Routine
200159007Fatalities reported
200064110Routine
199936000Routine
1998 — this page53030Routine
199723000Routine
199632020Routine

Compare every Mustang GT year →

Reading this record

No unusual pattern of severe incidents in the complaint record.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Most recent recall on file: none. Source: NHTSA Office of Defects Investigation.