Owners filed 32 complaints about this vehicle with federal regulators, most often about the power train › automatic transmission. It has been recalled 1 time.
What fails
Component
Reports
Crashes
Fires
Injuries
Tires
3
0
0
0
Power Train › Automatic Transmission
3
0
0
0
Engine and Engine Cooling › Engine › Gasoline
3
0
0
0
Tires › Sidewall
2
0
0
0
Seats › Front Assembly › Head Restraint
2
0
0
0
Seat Belts
2
1
0
1
Engine and Engine Cooling › Engine › Diesel
2
0
0
0
Suspension › Front › Wheel Bearing
1
0
0
0
Steering › Hydraulic Power Assist System
1
0
0
0
Steering › Steering Wheel/Handle Bar
1
0
0
0
1 safety recall
Part 573 reports
Fuel System, Gasoline › Storage › Tank Assembly › Filler Pipe and Cap01V106000
Filed Mar 27, 2001185 vehiclesFord Motor Company
Defect. VEHICLE DESCRIPTION: F-SUPER DUTY CREW CAB PICKUP TRUCKS (F-350 SHORT WHEELBASE TRUCKS EQUIPPED WITH A 6 3/4' PICKUP BOX AND DUAL REAR WHEELS) WERE BUILT AFTER A CHANGE WAS IMPLEMENTED TO DELETE A CLAMP, AND LATER A BRACKET THAT PROVIDED A GROUND FOR THE FUEL FILLER PIPE. THE PICKUP BOX MAY NOT HAVE BEEN PROPERLY GROUNDED.
Risk. WITHOUT PROPER GROUNDING, AN ELECTROSTATIC DISCHARGE COULD RESULT DURING FUEL FILL UP, POTENTIALLY LEADING TO A FIRE.
Remedy. DEALERS WILL INSTALL A FUEL FILLER PIPE GROUND. OWNER NOTIFICATION BEGAN MARCH 26, 2001. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT FORD AT 1-800-392-3673.
What owners reported
Newest filings
Seat Belts
Filed Feb 8, 2015GA
MY DRIVER SIDE FRONT SEAT BELT WILL COME UNBUCKLED FOR NO APPARENT REASON.NO MATTER SPEED ANGLE ETC. *JS
Engine
Filed Sep 4, 2014161,000 milesCO
FORD F250 2001 6.8 V-10 SPARK PLUG BLOW OUT I JUST HAD TWO OF MY TEN PLUGS BLOW OUT ON MY 2001 F250 GAS 6.8 V-10 WITH 161K MILES. I TUNED UP THE ENGINE AT THE RECOMMENDED 100K MILES USING THE SPECIFIED PROCEDURES FOR THIS ENGINE. I KNEW THERE WAS A PROBLEM WITH THIS ENGINE AND WAS EXTREMELY CAREFUL DURING THE TUNE-UP AND PLUG REPLACEMENT. I AM A CERTIFIED AIRCRAFT MECHANIC WITH FAA INSPECTION AUTHORIZATION. I USED A CERTIFIED TORQUE WRENCH TO INSTALL THE PLUG WITH THE CORRECT TORQUE. THERE WAS NO ERROR IN TECHNIQUE OR INSTALLATION ON THIS SPARK PLUG REPLACEMENT. I JUST PAID $720 TO HAVE TWO SPARK PLUG HELI-COIL INSERTS DONE ON THIS ENGINE THAT BLEW OUT THE TWO FRONT LEFT PLUGS. THERE IS A SIMILAR PROCEDURE FOR AIRCRAFT ALUMINUM CYLINDERS (CALLED JUGS) WITH STRIPPED SPARK PLUG BOSS DEFECTS. AN AIRCRAFT SPARK PLUG HAS A LARGER 18MM DIAMETER PLUG WITH FULL DEPTH THREADS (NOT THE ? THREAD OF THE FORD V-10 AND OTHER FORD ENGINE DESIGNS). AIRCRAFT SPARK PLUGS ARE TORQUED TO 35 FT/LBS (VS THE 8.9 FT/LBS (107 IN/LBS) SPECIFIED BY FORD). THE MAXIMUM RPM OF MOST AIRCRAFT ENGINES IS 2700 RPM AS OPPOSED TO 6000+ RPM IN THE FORD ENGINES. THIS RESULTS IN A SIGNIFICANTLY LESS STRESS ON THE PLUG BOSS AREA THAT IT WOULD HAVE IN A FORD ENGINE. THE ENGINEERING THOUGHT THAT WENT INTO THIS FORD DESIGN IS TOTALLY NONSENSICAL OR NON-EXISTENT. THERE IS NO LOGICAL REASON THAT THEY SHOULD DESIGN THIS THREAD DEPTH WITH ? DEPTH IN AN ALUMINUM HEAD INSTEAD OF THE FULLY AVAILABLE 7/8? OF THE SPARK PLUG TH
Power Train › Automatic Transmission
Filed Oct 14, 201092,000 milesOR
I PURCHASED A 2001 FORD SUPER DUTY NEW. THE TRANSMISSION FAILED AT 61K MILES AT 6 YEARS OLD. I REPLACED THAT TRANSMISSION WITH A 'REBUILT BY FORD' TRANSMISSION WITH A 3 YEAR, 36K MILE WARRANTY. THAT TRANSMISSION FAILED (DISINTEGRATED) WITH 31K MILES AT 37 MONTHS. ALTHOUGH THE DEALER IS HELPING WITH THE COST OF REPLACING IT AGAIN, FORD WILL NOT HELP AT ALL. THE REPLACEMENT TRANSMISSION FAILED TWICE UNDER WARRANTY AND WAS SERVICED WITH 25K MILES ON IT. *TR
Engine and Engine Cooling
Filed Mar 19, 2010123,475 milesAR
WAS SITTING AT STOP LIGHT, AND ALL OF A SUDDEN THERE WAS A POP, AND THIS TERRIBLE NOISE STARTED COMING FROM ENGINE AREA. PULLED INTO A PARKING LOT, AND CALLED MY HUSBAND. HE CAME DOWN, AND INSPECTED THE ENGINE. HE FOUND THE NUMBER 4 SPARK PLUG MISSING. THIS IS THE FIRST TIME THIS FAILURE HAS HAPPENED. HAD TRUCK TOWED TO A FORD DEALER, AND THEY INSTALLED A SPARK PLUG INSERT, AND REPLACED SPARK PLUG, AND COIL. $424.52 WAS TOTAL REPAIR BILL WHICH INCLUDED TOWING. OLD PARTS ARE NOT AVAILABLE. *TR
Fuel System, Gasoline › Fuel Injection System › Fuel Rail
Filed Nov 27, 2007125,000 milesNH
MY 2001 FORD F350 SUPERDUTY EJECTED A SPARK PLUG FOR THE SECOND TIME IN A YEAR. I FINALLY HAD TO BUY AN INSERT KIT TO FIX THE PROBLEM MYSELF COST ME 450.00 PLUS A NEW IGNITION COIL FOR 55.00. FORD WOULD NOT EVEN THINK OF TAKING THE BLAME FOR THIS PROBLEM TELLING ME THAT IT IS VERY UNCOMMON FOR THIS TO HAPPEN???????I DIDN'T HAVE A FIRE BUT I DID SEE SOME SMOKE AND SMELLED GAS VAPORS WHEN THE PLUG EJECTED IT ALSO SCARED THE HELL OUT OF MY WIFE AND I..IF IT HAPPENED ON THE INTERSTATE THERE COULD HAVE BEEN AN ACCIDENT FROM THE LOSS OF POWER AND THE SUDDEN SHOCK FROM THE NOISE.. I REALLY THINK THIS FAILURE IN THE FORD TRITON MOTOR SHOULD BE LOOKED AT CLOSELY AND MAKE FORD RECALL THESE ENGINES....THANK YOU DAVE CURTIN *TR
Engine and Engine Cooling › Engine › Diesel
Filed Aug 24, 2007CA
ENGINE STALLS AT IDLE. *TR
Seat Belts › Front › Buckle Assembly
Filed May 24, 2007124,000 milesMI
DRIVERS SEAT BELT RANDOMLY DISCONNECTS. MAY DISCONNECT 2 TIMES WITHIN 5 MINUTES OR MAY DISCONNECT ONCE IN 2 WEEKS. EVERYTIME I CONNECT THE BELT I TUG AND YANK TO MAKE SURE IT IS CONNECTED BUT DOING THIS MAKES NO DIFFERENCE. I HOPE IT DOES NOT DISCONNECT IN AN ACCIDENT.
Engine and Engine Cooling › Engine
Filed Aug 12, 200520,718 milesIA
2002 CLASS A MOTORHOME SPARK PLUG HAD BLOWN OUT THE ENGINE HEAD UPON START UP. *MR THE CONSUMER STARTED THE VEHICLE AND HEARD A LOUD NOISE. IT WAS DISCOVERED THAT THE #1 SPARK PLUG HAD EXITED THE ENGINE HEAD AND WAS LODGED IN THE FRONT AXLE. THE CONSUMER REQUESTED REIMBURSEMENT. *SC
Electrical System
Filed Aug 6, 200540,000 milesNM
MY 2001 FORD F-350 7.3 L POWER STROKE DIESEL HAS BEEN EXPERIENCING STALLING, MISSING,CUTTING OUT, ETC FOR ABOUT 6-8 MONTHS. THE TRUCK WAS TAKEN TO CAPITOL FRD IN SANTA FE, NM ON JUNE 7, 2005 AND PICKED UP ON JUNE 11, 2005. THE SERVICE TECHNICIANS REPLACED A "RELAY" OF SOME SORT NOT KNOWING WHAT THE PROBLEM REALLY WAS.(BY THEIR OWN ADMISSION).THE TRUCK STILL STALLS, MISSES AND CUTS OUT. I DO NOT WANT TO CONTINUE TAKING MY TRUCK IN FOR EXPERIMENTS TO DETERMINE THE CAUSE OF THE PROBLEM. THEY ARE VERY NICE AND TRY TO HELP BUT I CANNOT AFFORD TO BUY FUEL FOR THEM TO RECREATE THE PROBLEM. THE LAST TIME WAS 4 DAYS AND 15 GALLONS OF FUEL. THE TRUCK HAS DIED WHILE IN MOTION ON AT LEAST 6 DIFFERENT OCCASIONS AND NUMEROUS TIMES SITTING AT STOP LIGHTS. WHEN IT DIES IN MOTION, I LOSE POWER STEERING AND POWER BRAKES. PLEASE HELP!!! *JB
Power Train › Clutch Assembly › Pedal/Hand Lever(motorcycle)
Filed Jun 21, 200583,000 milesNC
CLUTCH DISENGAGEMENT NEEDING MORE TRAVEL UNTIL NEARLY TOUCHING THE FLOOR, OCCURED OVER A FEW WEEKS. THE CLUTCH STOPPED DISENGAGING WHILE TOWING A TRAILER OUT OF STATE AT A STOP LIGHT. IF THE IGNITION KEY WASN'T TURNED OFF IT WOULD HAVE PUSHED US INTO ONCOMING TRAFFIC. THE CLUTCH MASTER CYLINDER WAS REPLACED, THE OLD PART IS AVALIABLE. I UNDERSTAND THIS IS A COMMON PROBLEM WITH THE SUPER DUTY FORD PICKUPS WITH MANUAL TRANSMISSIONS. THIS IS THE SECOND TIME IT HAS HAPPENED. THE FIRST WAS ABOUT 43K MILES, NOW IT IS 83K MILES. SEVERAL OWNERS OF THE SAME TYPE TRUCKS (ALL WITH DIESEL ENGINES) HAVE HAD SIMILAR PROBLEMS.
Power Train › Automatic Transmission
Filed Nov 30, 200434,800 milesIN
NORMAL DRIVING RANSMISSION BROKE.FORD REPLACED TRANSMISSION. *AK
Engine and Engine Cooling › Engine › Diesel
Filed Jan 8, 200462,000 milesOH
I WAS DRIVING A 2001 FORD F250 SUPER DUTY TRUCK WITH A DIESEL MOTOR, I WAS DRIVING ON A RURAL ROAD GOING ABOUT 55 MPH WHEN THE MOTOR DIED FOR NO REASON. I COASTED TO THE SIDE OF THE ROAD AND CALLED FOR HELP BECAUSE THE TRUCK WOULD NOT START. I HAD THE TRUCK TOWED TO THE DEALER AND THEY SAID THE CAM POSITION SENSOR WENT BAD. WHEN THIS PART GOES BAD THE ENGINE GOES DEAD. THE PROBLEM IS THESE TRUCKS ARE MADE FOR TOWING TRAILER AND WHEN THE MOTOR DIES FOR NO REASON YOU HAVE NO POWER TO STEER THE TRUCK AND THE BRAKE NO LONGER WORK. THIS PART NEEDS TO BE RECALLED AND FIXED. I HAVE TALKED WITH SEVERAL PEOPLE WHO HAVE HAD THIS HAPPEN TO THEM AS WELL. THIS IS A VERY DANGEROUS PROBLEM THAT IS GOING TO GET SOMEONE HURT OR KILLED. *LA
Power Train › Automatic Transmission › Torque Converter
Filed Aug 23, 200379,000 milesIL
THE TRANSMISSION IN MY 2001 FORD F250 WAS REPLACED UNDER WARRANTY WITH A FORD REMAN UNIT LAST SUMMER (JULY 2002 WITH 59000 MILES). THIS AUGUST(2003) IT BEGAN PUMPING OUT TRANSMISSION FLUID FROM THE BELL HOUSING AT APPROXIMATELY 79000 MILES. THE DEALER DETERMINED THAT IT NEEDED A NEW TORQUE CONVERTER. THAT'S THE SAME DIAGNOSIS IT HAD LAST YEAR. OF COURSE, FORD WILL NOT WARRANTY IT. IT APPEARS TO ME THAT FORD HAS A SERIOUS PROBLEM WITH THEIR TRANSMISSIONS. THE SECOND ONLY LASTED 13 MONTHS AND 20000 MILES. THIS IS THE SECOND FORD VEHICLE I'VE OWNED WITH FAULTY TRANSMISSIONS. THE OTHER WAS THE 1999 WINDSTAR. THAT TRANSMISSION WENT AT 53,000 MILES AND HAD NEVER TOWED ANYTHING OR BEEN OVERHEATED.*AK
Tires
Filed May 20, 2003MO
MY REAR TIRE BLEW OUT WHILE TRAVELING 55 MILES AN HOUR. THE TIRE WAS PROPERLY INFLATED AND HAD LESS THAN 30000 MILES OF WEAR. THE TIRE LOOK AS IF IT CAME UNGLUED. *NLM
Service Brakes, Hydraulic › Foundation Components › Disc
Filed Sep 21, 2002ID
WHEN THE PICKUP IS PARKED ON A SLIGHT INCLINE IN FIRST,SECOND,THIRD GEAR, IF YOU DO NOT CRAM ON THE BRAKE AS HARD AS YOU CAN THE TRUCK WILL ROLL BACKWARDS! IF YOU DON'T HAVE BRAKE YOU WATCH TRUCK ROLL BACKWARDS. THE FORD HOTLINE SAID THIS NORMAL. I HAVE DROVE MANUEL TRANSMISSIONS ALL MY LIFE,THIS IS NOT NORMAL! MY TRUCK HAS ROLLED OVER 20 FEET OUT INTO THE STREET.I AM CONCERNED THAT IT COULD POP OUT OF GEAR AND CAUSE A ACCIDENT OR RUN OVER SOMEONE! THE BRAKE SYSTEM IS NOT GOOD ENOUGH AND THE TRANSMISSION OR REAREND HAS A PROBLEM.*AK
Tires › Sidewall
Filed Jul 15, 2002CA
SIDEWALL FAILER FOUND BY EAST COUNTY ALLINGMENT, SANTEE, CA. THEY HAVE FOUND MANY PROBLEMS WITH THIS MODEL TIRE. ON SEARCHING FOR A REPLACEMENT TIRE TWO DEALERS WOULD NOT RECOMEND THIS TIRE AND ONE, SOUTHERN TIRE, RAMONA CA. , HAD A NEW ONE BLOW UP.*AK
Tires › Sidewall
Filed Jun 27, 2002LA
TRAVELLING WITH EMPTY PICKUP TRUCK BED AND 1 ADULT AND 3 CHILDREN PASSENGERS. 50 MILES FROM LAKE CHARLES, LA. AFTER DRIVING FOR 9 HOURS, THE RIGHT REAR FIRESTONE STEELTEX 16 INCH TIRE HAD A CATASTROPHIC SIDEWALL FAILURE. THE SIDEWALL SEPARATED ENTIRELY FROM THE OUTSIDE OF THE TIRE. I HAVE PHOTOS AND HAVE THE ORIGINAL TIRE AND SIDEWALL. I REPLACED ALL THE FIRESTONE TIRES WITH MICHELINS. SOMEONE NEEDS TO GET FIRESTONE TO LOOK INTO THIS. THE TIRE WAS MADE IN CANADA AND THE FOLLOWING NUMBERS ARE ON THE SIDEWALL IN VARIOUS LOCATIONS: 30362 EX BM14480-3 BM14973 AND BM15211 ON THE TIRE BEAD. THEY ARE E RATED TUBELESS RADIAL ORIGINAL EQUIPMENT TIRES ON MY FORD SUPERDUTY. FEEL FREE TO CONTACT ME FOR PHOTOS OR TO SEE THE TIRES.*AK
Power Train › Clutch Assembly
Filed Dec 27, 2001MN
PROBLEM WITH CLUTCH FAILUE DUE TO LOSS OF FLUID.*AKTHE PINS HOLD THE CONNECTION BETWEEN THE CLUTCH MASTER CYLINDER AND THE SLAVE CYLINDER CAME OUT CAUSING FLUID TO LEAK AND RESULTING IN THE CLUTCH FAILING, THIS FAILURE OCCURED TWICE AND WAS NOT FIXED PROPERLY THE FIRST TIME. *NLM
Seat BeltsCrash1 injured
Filed Dec 27, 2001CA
FRITTS FORD SOLD ME THE TRUCK WITHOUT CHECKING WHEN I BROUGHT IN FOR SERVICE - A FEW DAYS LATER I WAS INJURED WHEN THE SEAT BELT FAILED. I HAVE REPLACED THE BELT.*AK
Engine and Engine Cooling › Engine › Gasoline
Filed Dec 18, 2001AK
MY TRUCK HAS STARTED TO STALL OUT IN REVERSE SINCE 9/19/01. THE PROBLEM HAS CONTINUED SINCE THAN. I HAVE BEEN IN CONTACT WITH THE DEALERSHIP AND FORD CUSTOMER ASSISTANCE. THE SERVICE MANAGER AT SEEKINS FORD IN FAIRBANKS ALASKA HAS SEEN THIS PROBLEM SINCE 1998 AND THERE HAS BEEN NO SOLUTION. CURRENTLY HE HAS 12 FORD F-SERIES TRUCK THAT ARE STALLING OUT IN REVERSE. IT ONLY STALLS OUT AT -10DEGREES OR COLDER. THE DEALERSHIP HAS CHANGED THE TRANSMISSION FLUID TO A SYNTHETIC FLUID BUT AN HOUR AFTER DRIVING OFF THE LOT IT STALLED 5 TIMES AND HAS CONTINUED SINCE. I HAVE HAD NO HELP FROM FORD AND I AM VERY WORRIED THAT MY TRUCK WILL STALL OUT AND NOT START IN THE MIDDLE OF AN INTERSECTION AND I WILL BE INVOLVED IN AN ACCIDENT. I CANNOT BACK OUT OF A PARKING SPACE WITHOUT STALLING OUT 3-5 TIMES. MY STARTER IS NOW GETTING USED 5 TIMES AS MUCH AND I THINK THE REST OF MY TRUCK IS ALSO GETTING DAMAGE DUE TO THIS PROBLEM. I HAVE BEEN TOLD TO CALL MANY DIFFERENT NUMBERS AND NOW I AM ALMOST TWO MONTHS INTO THIS PROBLEM WITH NO SOLUTION IN SIGHT. THERE ARE MANY OTHER PEOPLE WHO OWN THESE VEHICLES WHO HAVE THE SAME PROBLEM BUT THE FORD DEALERSHIP ASKS PEOPLE NOT TO CALL CUSTOMER ASSISTANCE TO REPORT THIS PROBLEM. THE SEEKINS FORD SERVICE MANAGER(AL) 907-459-4079 HAS A LIST OF ALL THE PEOPLE WITH THE SAME PROBLEM. I HOPE THAT YOU CAN HELP. THANK YOU. *AK
No unusual pattern of severe incidents in the complaint record.
Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.
Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.
Most recent recall on file: Mar 27, 2001. Source: NHTSA Office of Defects Investigation.