2010 Blue Bird All American

Routine

No owner complaints are on file for this vehicle. It has been recalled 42 times.

42 safety recalls

Part 573 reports
Parking Brake20V234000
Filed Apr 27, 20202,264 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain 2006-2021 Vision and 2007-2013 All American school buses. The floor-mounted parking brake may fail to hold the vehicle stationary on an incline when the vehicle is loaded to its maximum weight, due to an insufficient application force. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 105, "Hydraulic and Electric Brake Systems."

Risk. A parking brake system that is set to an insufficient application force may result in an increased possibility of unintended vehicle movement, which increases the risk of a crash.

Remedy. Blue Bird will notify owners, and dealers will inspect the floor mounted park brake application force hand lever assembly and correct the application force, as necessary, free of charge. The recall is expected to begin June 24, 2020. Owners may contact Blue Bird customer service at 478-822-2242. Blue Bird's number for this recall is R20AO-SB.

Seats › Barriers20V125000
Filed Mar 3, 20202,790 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain 2008-2021 Vision and All American school buses. The seat barrier behind the driver seat with an integrated 3-point seat belt may have been installed incorrectly and may be missing the reinforcing bracket. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 222, "School Bus Passenger Seating and Crash Protection."

Risk. In the event of a crash, the seat barrier may not adequately protect the occupant seated behind the seat barrier separating them from the driver seat with integrated 3-point seat belt, increasing the risk of injury.

Remedy. Blue Bird will notify owners, and dealers will inspect and properly install the seat barrier including adding reinforcing bracket, as necessary, free of charge. The recall is expected to begin April 23, 2020. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's number for this recall is R20AM-SB.

Equipment18V801000
Filed Nov 14, 201886 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain 2007-2019 Blue Bird All American ambulance buses. The clamps that secure the stacked stretchers may fail from repeated use or from high loads.

Risk. If the clamps fail with patients in the stretchers, it can increase the risk of injury.

Remedy. Blue Bird will notify owners, and dealers will install redesigned clamps, free of charge. The recall began December 12, 2018. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's number for this recall is R18ZQ-NSB.

Equipment Adaptive/Mobility15V731000
Filed Nov 4, 201590 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American and Vision and 2007-2011 Micro Bird transit buses equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured January 1, 2006, to August 25, 2014 by the Ricon Corporation. The affected lifts are equipped with folding link arms that may have pivot holes that are too big, allowing the bearings to move out of position.

Risk. If the bearings move out of position, the stowed platform may have excessive movement resulting in failure of the platform mounting. This failure could cause the wheel chair lift platform to fall out of the vehicle when the doors are opened, increasing the risk of injury for the lift operator.

Remedy. Blue Bird will notify owners, and Ricon dealers will inspect the link arms for damage or for displaced bearings. The platform will be inspected for cracks. Any damaged parts will be replaced, free of charge. The recall began on December 1, 2015. Owners may contact Blue Bird customer service at 1-478-822-2242, or Ricon Customer Service at 1-800-322-2884.

Equipment Adaptive/Mobility15V730000
Filed Nov 4, 20155,114 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American, Vision, 2007-2011 Micro Bird, and 2007-2008 Conventional school buses, equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured January 1, 2006, to August 25, 2014 by the Ricon Corporation. The affected lifts are equipped with folding link arms that may have pivot holes that are too big, allowing the bearings to move out of position.

Risk. If the bearings move out of position, the stowed platform may have excessive movement resulting in failure of the platform mounting. This failure could cause the wheel chair lift platform to fall out of the vehicle when the doors are opened, increasing the risk of injury for the lift operator.

Remedy. Blue Bird will notify owners, and Ricon dealers will inspect the link arms for damage or for displaced bearings. The platform will be inspected for cracks. Any damaged parts will be replaced, free of charge. The recall began on December 1, 2015. Owners may contact Blue Bird customer service at 1-478-822-2242, or Ricon Customer Service at 1-800-322-2884.

Engine and Engine Cooling › Engine15V294000
Filed May 19, 201534 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2009-2016 All American rear engine non school buses manufactured December 7, 2008, to May 11, 2015, and equipped with certain Cummins Westport ISL G engines. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.

Risk. If engine oil comes into contact with a hot surface, there is an increased risk of a fire.

Remedy. Cummins will notify owners on behalf of Blue Bird, and Cummins service centers will administer the repairs which include securing the ends of the 90-degree elbow and reprogramming the electronic control module (ECM) with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 12, 2015. Owners may contact Blue Bird customer service at 1-478-822-2242 or Cummins Inc. at 1-800-343-7357. Blue Bird's number for this recall is R15YE-NSB.

Engine and Engine Cooling › Engine15V293000
Filed May 19, 2015840 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2009-2016 All American rear engine school buses manufactured December 7, 2008, to May 11, 2015, and equipped with certain Cummins Westport ISL G engines. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.

Risk. If engine oil comes into contact with a hot surface, there is an increased risk of a fire.

Remedy. Cummins will notify owners on behalf of Blue Bird, and Cummins service centers will administer the repairs which include securing the ends of the 90-degree elbow and reprogramming the electronic control module (ECM) with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These repairs will be performed free of charge. The recall began on June 12, 2015. Owners may contact Blue Bird customer service at 1-478-822-2242 or Cummins Inc. at 1-800-343-7357. Blue Bird's number for this recall is R15YE-SB.

Equipment Adaptive/Mobility14V511000
Filed Aug 19, 201490 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American, 2007-2010 Micro Bird, and 2007-2014 Vision non-school buses equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon Corporation. The platform side plate of the affected wheelchair lifts may crack.

Risk. If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.

Remedy. Blue Bird will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on October 1, 2014. Owners may contact Blue Bird customer service at 1-478-822-2242 or Ricon customer service at 1-800-322-2884. Blue Bird's number for this recall is R14XN.

Equipment Adaptive/Mobility14V510000
Filed Aug 19, 20145,114 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2007-2015 All American and Vision, 2007-2011 Micro Bird, and 2007-2008 Conventional school buses equipped with certain model S2005, S2010, S5005, S5010, S5505, and S5510 wheelchair lifts manufactured by Ricon Corporation. The platform side plate of the affected wheelchair lifts may crack.

Risk. If the platform side plates crack, the lift platform can separate from the lift and come to rest against the vehicle's lift door. When the doors are opened, the platform may fall out, increasing the risk of injury to the lift operator.

Remedy. Blue Bird will notify owners to take buses to a Ricon dealer or service center who will install supplemental platform support bumpers. Any platform that has already started cracking will be replaced, free of charge. The recall began on October 1, 2014. Owners may contact Blue Bird customer service at 1-478-822-2242 or Ricon customer service at 1-800-322-2884. Blue Bird's number for this recall is R14XN.

Engine and Engine Cooling › Cooling System › Hoses/Lines/Piping/Fittings14V314000
Filed Jun 11, 2014587 vehiclesBlue Bird Body Company

Defect. Blue Bird Body Company (Blue Bird) is recalling certain model year 2008-2013 All American rear engine non-school buses manufactured May 9, 2007, to November 12, 2012. Due to the design of the thermostat, a heater hose may rupture which could result in hot coolant entering the passenger compartment.

Risk. Hot coolant leaking into the passenger compartment increases the risk of injury to the passengers.

Remedy. Blue Bird will notify owners, and dealers will replace the thermostat and change the passenger compartment heater supply hose, free of charge. The recall began on July 15, 2014. Owners may contact Blue Bird customer service at 1-478-822-2242. Blue Bird's number for this recall is R14XF.

Showing 10 of 42 campaigns, newest first.

Across model years

Worst on record: 1992
YearComplaintsRecallsFiresDeathsAssessment
201922600Routine
201801900Routine
201701000Routine
201612000Routine
201532700Routine
201402600Routine
201312800Routine
201203000Routine
201103500Routine
2010 — this page04200Routine
200933300Routine
200843200Routine
200742110Routine
200621500Routine
200511300Routine
2004101500Routine
200321100Routine
200211400Routine
200111400Routine
200001600Routine
199901600Routine
19981900Routine
19970300Routine
19960600Routine
199501100Routine
19940900Routine
19930700Routine
199216900Routine
19910900Routine
19900900Routine

Compare every All American year →

Reading this record

No unusual pattern of severe incidents in the complaint record.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.

Most recent recall on file: Apr 27, 2020. Source: NHTSA Office of Defects Investigation.