NHTSA campaign 04V227000 · Part 573 safety recall report

Mercedes-Benz USA, LLC.: Electrical System › Wiring › Fuses and Circuit Breakers

Mercedes-Benz USA, LLC. reported this defect to federal regulators on May 13, 2004 and put the number of vehicles at risk at 54,454. The repair is free for as long as the recall stands.

The defect

ON CERTAIN PASSENGER VEHICLES, DURING THE PRODUCTION PROCESS OF THE BLOWER MOTOR FUSE HOLDER, THE SIZE OF THE ELECTRIC CONDUCTOR OF THE HOLDER MAY BE BELOW APPROPRIATE TOLERANCES.

The risk

CONSEQUENTLY, THE ELECTRIC CONDUCTOR OF THE BLOWER MOTOR FUSE HOLDER MAY DISSIPATE MORE HEAT THAN THE PLASTIC FUSE HOLDER WAS DESIGNED TO WITHSTAND, WHICH COULD RESULT IN OVERHEATING OF THE HOLDER AND DISABLING OF THE BLOWER MOTOR AND THE ABILITY TO DEFROST OR DEFOG THE WINDSHILED IN COLD OR HOT AND HUMID WEATHER CONDITIONS. DEPENDING ON THE OCCURRENCE AND WEATHER SITUATION, DRIVER VISIBILITY COULD BE REDUCED, WHICH COULD RESULT IN A CRASH.

The remedy

DEALERS WILL INSTALL NEW BLOWER MOTOR FUSE HOLDERS. THE RECALL BEGAN DURING OCTOBER 2004. OWNERS SHOULD CONTACT MERCEDES-BENZ AT 1-800-367-6372.

4 model years covered

Newest first

What this page is, and what to do next

A recall is not an opinion. It is a Part 573 report a manufacturer is required by federal law to file once it decides a defect poses an unreasonable risk to safety, and it commits them to repairing the vehicle at no cost to the owner. The three passages above are the manufacturer’s own wording as published by NHTSA.

This page describes the campaign. It cannot tell you whether one particular car has already been through the shop — that is tracked by VIN, and only the manufacturer knows it. Check yours at nhtsa.gov/recalls or with a franchised dealer, quoting campaign number 04V227000.

Full record for the 2001 Mercedes Benz CL Class → · Recalls carrying a do-not-drive advisory → · Where this data comes from →