THE VEHICLE EXPERIENCED THREE BLOWOUTS, ONE WHICH DAMAGED THE FRONT END AND RIM. NLM
1993 Ford F-150 complaints
Owner reports filed with NHTSA about this vehicle, newest first and reproduced as filed. They are unverified accounts: one proves nothing, and a pattern across many is the thing worth reading. Back to the full 1993 record →
CONSUMER HAD FUEL PUMP REPLACED IN OCT 2000 DUE TO FUEL LEAKAGE, AT THIS TIME VEHICLE'S FUEL TANKS ARE LEAKING AGAIN. FUEL IS BEING PUMPED FROM ONE FUEL TANK TO THE OTHER.THIS VEHICLE IS NOT AFFECTED BY RECALL 00V424000. *AK *SLC
MY VEHICLE WAS RECALLED BY THE NHTSA FOR REPAIR. I TOOK MY VEHICLE TO THE LOCAL DEALERSHIP FOR REPAIR. THEY SAID THEY DID NOT HAVE ANY RECALL FROM FORD SAYING VEHICLE NEEDED REPAIRED AND THAT I SHOULD WAIT FOR NOTIFICATION IN THE MAIL FROM THE FORD COMPANY. STRONG GASOLINE FUMES WERE BEGINNING TO EMIT FROM THE ENGINE AND VEHICLE WAS CONTINUEING TO STALL WHILE DRIVING. I DID NOT WANT MY VEHICLE TO CATCH FIRE AND DUE TO IT STALLING I HAD IT REPAIRED AT MY OWN COST. I CALLED FORD AND ASKED IF THEY HAD THE RECALL AND THEY STILL HAVE NO RECALL. MY VEHICLE IS COMING UP ON THE 8 YEAR TIME LIMIT FOR RECALL WARRANTY. WHAT SHOULD I DO? WILL I BE REFUNDED ON MY COSTS? THE NHTSA CAMPAIGN ID NUMBER IS 00V424000 / ANOTHER IS 93V125000. THANK YOU. *AK
WHEN TURNING ON AIR CONDITIONING SAW A PUFF OF SMOKE COME FROM VENTS WHERE AIR BLOWS THROUGH. THEN, SMELLED SOMETHING ELECTRICAL BURNING LIKE WIRES. NEXT THE WHOLE VEHICLE CAUGHT ON FIRE. VEHICLE WAS TOTALLED. PLEASE PROVIDE ANY FURTHER INFORMATION.*AK
NO SUMMARY LISTED FOR ABOVE VEHICLE. *AK
CONSUMER HAS SOME FUEL LEAKAGE. FUEL WOULD SPURT OUT WHENEVER OPENING GAS TANK. THERE IS A RECALL ON VEHICLE FOR SAME PROBLEM, BUT CONSUMER'S VEHICLE IS NOT INCLUDED. *AK
FUEL WAS LEAKING AND SPILLING OUT OF FUEL TANK. CONSUMER TOOK VEHICLE IN, BUT RECALL 00V424000/ MANUFACTURER'S RECALL 00S57 DIDN'T APPLY TO THIS VEHICLE. DEALER HAD TO REPLACE CARBON STEEL PRESSURE REGULATOR. IT WAS CAUSING PRESSURE BUILD UP, AND PUSHING IT FROM ONE TANK TO OTHER. DEALER STATED VALVE WAS DEFECTIVE, AND DIDN'T STOP IT FROM FLOWING. *AK
RECALL OO V 424 000/FUEL LEAKAGE: A PORTION OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO SECOND TANK. WHEN THIS OCCURS SECOND TANK EXCEEDED ITS LIMITS, CAUSING FUEL SPILLAGES. SPILL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER NOTIFIED, AND INFORMED CONSUMER THAT THIS VEHICLE WAS NOT COVER UNDER RECALL DUE TO VIN. FEEL FREE TO PROVIDE US WITH ANY FURTHER INFORMATION CONCERNING THIS MATTER. *AK
WHEN FILLING BOTH TANKS, BACK TANK WILL FLOW GASOLINE INTO FIRST TANK. THERE IS A HUMMING NOISE IN REAR TANK WHERE THE PUMP IS LOCATED. HE WILL CONTACT DEALERSHIP. *AK *SLC
FUEL TANK LEAKED BECAUSE OF BUILT UP PRESSURE WHEN CONSUMER REMOVED THE CAP FROM TANK. MANUFACTURER INFORMED CONSUMER THAT THIS VEHICLE WAS NOT INCLUDED IN RECALLS 93V125000 OR 00V424000 DUE TO VIN. *AK *SLC
REAR TANK LEAKS. I TOOK TO DEALER THEY SAID THEY FOUND NO LEAK ,SINCE THEN IT STILL LEAKS AND RUINED THE SPARE,I NO LONGER USE THE REAR TANK
WHEN STARTING VEHICLE FOR FIRST TIME IT WILL NOT START. CONSUMER WOULD HAVE TO TRY A FEW TIMES. ALSO, WHILE TRAVELING VEHICLE WOULD RUN OUT OF GAS DUE TO FUEL TRAVELING INTO 2ND TANK. *AK *SLC
WHILE VEHICLE WAS IDLING AND IT HAD A FULL TANK OF GAS, FUEL BEGAN LEAKING FROM FUEL TANK FILLER HOSE. CONSUMER CONTACTED MANUFACTURER, AND WAS INFORMED THAT THIS VEHICLE WAS NOT INCLUDED IN RECALLS 00V424000 OR 93V12500. *AK *JB
DUAL TANKS; FUEL FLOWS FROM ONE TANK TO OTHER EXCEEDS LIMITS, AND EXPELS PART OF THE FLUID. *AK *JB
ONGOING / INTERMITTENT PROBLEM OF ENGINE STALLING WHILE DRIVING AT ANY GIVEN SPEED. DEALER NOTIFIED, AND WAS UNABLE TO LOCATE PROBLEM AT THIS TIME. FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER. *AK
A NOISE WAS COMING FROM SECOND TANK. DEALER WAS NOTIFIED, AND INFOMED CONSUMER THAT BOTH FUEL TANKS NEEDED TO BE REPLACED AT CONSUMER'S EXPENSE. PLEASE FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER. *AK
THIS VEHICLE NOT INCLUDED IN RECALL 93V125000. A MALFUNCTIONING CHECK VALVE ALLOWS FUEL FROM ONE TANK TO TRANSFER TO SECOND TANK, CAUSING FUEL LEAKAGE. *AK THE CONSUMER USED ONLY ONE OF THE FUEL TANK TO AVOID FUEL OVER FLOW. *YH
WAS DRIVING 35-40MPH DOWNHILL WHEN A DEER STEPPED OUT ON ROAD, CONSUMER APPLIED BRAKES, AND THEY FAILED TO STOP VEHICLE. PEDAL WENT TO FLOOR. HAD DOWNSHIFTED, AND ALSO USED EMERGENCY BRAKES. WENT THROUGH STOP SIGNS. FINALLY ,VEHICLE STOPPED. CHECKED VEHICLE OUT, AND NOTICED BRAKE LINE JUNCTION HAD CORRODED AND WAS RUSTY, AND BRAKE FLUID HAD LEAKED OUT. *AK *JB
FUEL STARTED FLOWING OUT OF MY FRONT FUEL TANK FILL CAP WHEN I WAS STOPPED AT A STOP SIGN, WHICH WAS CAUSED BY A BAD FUEL PRESSURE REGULATOR WHICH CAUSED THE FUEL PUMP CHECK VALVES TO GO BAD WHICH ALLOWED THE PUMPS TO PUMP THE GAS INTO THE OTHER TANK AND OUT THE FILL CAP. I WENT TO FOR TO SEE ABOUT A RECALL BUT THEY SAID THAT THERE WASNT ANY. I SAW A RECALL ON THE INTERNET FOR THE SAME PROBLEM AND IT IS SUPPOSED TO BE FOR THE SAME YEAR AS MY TRUCK. .*AK
THERE IS A RECALL ON FUEL LEAKAGE; BUT THIS VEHICLE IS NOT INCLUDED ALTHOUGH IT HAS THE SAME SYMPTOMS AS IN RECALL. *AK
DUAL FUEL TANKS HAVE A MALFUNCTIONING CHECK VALVE WHICH ALLOWS FUEL TO FLOW FREELY BETWEEN TANKS. CONSUMER WAS INFORMED THAT THIS VEHICLE WAS NOT INCLUDED IN EITHER FUEL RELATED RECALLS 93V125000 OR 00V424000. *AK *JB
DUAL FUEL TANK SYSTEM IS LEAKING FUEL ONTO EXHAUST PIPE. CONSUMER CONTACTED MANUFACTURER , AND WAS INFORMED HIS VEHICLE WAS NOT INCLUDED IN EITHER NHTSA RECALL 00V424000 OR 93V125000. PLEASE PROVIDE ANY ADDITIONAL INFORMATION/ATTACHMENTS.*AK
FUEL TRANSFER FROM TANK TO TANK, OVERFLOW TO GROUND, LUCKY NO FIRE...YET. *AK
VEHICLE IS SHOWING THE SAME DEFECT AS LISTED IN RECALL CAMPAIGN 00V424000/ FUEL PUMP CHECK VALVE - DUAL FUEL TANK SYSTEM FAILURE. FUEL FROM ONE TANK WILL FLOW INTO OTHER TANK EVERYTIME CONSUMER DRIVES VEHICLE. DEALERSHIP INFORMED CONUMER THAT THERE WAS NO RECALL FOR THIS DEFECT. A PRIVATE MECHANIC GAVE CONSUMER A PRINT OUT REGARDING THE RECALL. *AK SPILLED FUEL COULD RESULT IN A FIRE UNLESS THE PRESSURE REGULATOR IS REPLACED AND REDUNDANT CHECK VALVE IS INSTLLED. *YH
VEHICLE IS SHOWING THE EXACT SYMPTOMS AS DESCRIBED IN RECALL 00V424000. CONSUMER HAD FRONT FUEL PUMP REPLACED LAST MONTH BECAUSE FUEL FROM FRONT TANK WAS BEING TRANSFERRED TO REAR FUEL TANK (DUAL TANK SYSTEM.) ALSO, CONSUMER FILLED FRONT TANK, THEN WENT TO FILL THE REAR TANK, HE WAS SHOWERED WITH FUEL. DEALERSHIP WAS SAYING THAT THEY WERE UNAWARE OF THIS RECALL SINCE CONSUMER NOTIFICATION WAS SCHEDULED TO BEGIN IN MAY OF 2001, MANUFACTURER AND DEALERSHIP WERE NOT ASSISTING CONSUMER IN ANY WAY TO REPAIR THIS DEFECT. HE HAS NO WAY OF KNOWING WHETHER HE IS INCLUDED IN THE RECALL. PLEASE PROVIDE ANY ADDITIONAL/INFORMATION.*AK
FUEL FROM ONE OF MY TWO GAS TANKS FLOWS INTO THE OTHER TANK. I THEN NOTE A DISTINCT ODOR OF GASOLINE, AND IF I REMOVE THE GAS CAP, GASOLINE WILL SPILL OUT OF THE TANK. IN ADDITION, THE REAR TANK HAS NOW DEVELOPED A LEAK. I UNDERSTAND THAT CERTAIN 1993 F150 FORD PICKUPS WERE RECALLED IN 1993 FOR HIGH FUEL PRESSURE DUE TO A FAULTY FUEL PRESSURE REGULATOR WHICH COULD DAMAGE THE FUEL PUMP CHECK VALVE. THIS ALLOWS FUEL TO TO TRANSFERRED FROM ONE TANK TO THE OTHER, POSSIBLY OVERFILLING THE NON-OPERATING TANK, RESULTING IN FUEL OVERFLOW PAST THE FILLER CAP (NHTSA #93V125000) AND MORE WILL BE RECALLED IN MAY (NHTSA #00V424000, MFG #00S57). I HAVE CALLED FORD, BUT THEY CANNOT TELL ME IF BY VEHICLE WILL BE INCLUDED IN THIS NEW RECALL. IT WAS NOT RECALLED IN 1993, EVEN THOUGH IT HAS EXPERIENCED THE SAME PROBLEMS AS NOTED IN THE TWO RECALLS THAT I REFER TO.*AK
93 V 125 000/FUEL TANK ASSEMBLY: A PORTION OF THE UNUSED FUEL FROM ONE TANK WAS T RETURNED TO SECOND TANK. WHEN THIS OCCURRED, SECOND TANK EXCEEDEDITS LIMIT, CAUSING FUEL SPILLAGE. SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. DEALER / MANUFACTURER WERE NOTIFIED, AND INFORMED CONSUMER THAT VEHICLE WAS NOT COVERED UNDER A RECALL. PLEASE FEEL FREE TO PROVIDE ANY FURTHER DETAILS ON THIS MATTER . *AK
THIS HAS BEEN ADRESSED BY NHTSA /FORD SAYS MY VEHICLE IS NOT COVERED. SEEMS EQUIVALENT TO RECALL NO. OOV424. NO SAFETY DEFECT MENTIONED. *AK
THE FUEL TANK ASSEMBLY FAILED. NLM
DUAL FUEL TANKS WOULD HAVE FUEL OVERFLOWING FROM ONE TANK TO ANOTHER, AND THEN WOULD SPILL OUT. ALSO, WINDSHIELD WIPERS WOULD STOP ON THEIR OWN. WIPER PROBLEM WAS INTERMITTENT.*AK
THE SHOCK BRACKETS COLLAPSED AND THE PERSON LOSES CONTROL OVER THE VEHICLE.*AK
VEHICLE IS EQUIPPED WITH DUEL TANKS, AND WHEN ONE TANK IS FULL IT SPILLS INTO OTHER TANK. HAS NOT CONTACTED DEALER YET.*AK WHEN BOTH TANKS BECOME FULL, THE GAS DUMPS OUT OF THE TANKS ON THE GROUND. *YH
CONSUMER CONTACTED DEALER IN REFERENCE TO RECALL 93V125000/MANUFACTURER'S RECALL 93S68. DEALER AND MANUFACTURER NOTED THIS VEHICLE NOT INCLUDED IN RECALL. VEHICLE WAS PASSING FUEL FROM ONE TANK TO ANOTHER WHICH CAUSED A FUEL LEAKAGE AT THE SIDE OF TRUCK. *AK THE PRESSURE INSIDE THE TANK GETS EXTREMELY HIGH CAUSING FEELER CAPS TO BLOW OUT AND GAS LEAKING IN FRAME RAIL. THE VEHICLE'S BODY SIDE MOULDING WAS PERMANENTLY DISCOLORED. HOWEVER, THE MANUFACTURER SAYS THIS VEHICLE WAS NOT INCLUDED IN THE RECALL. *YH
FUEL TANK ASSEMBLY (FRONT AND REAR) IS LEAKING AT SEAMS. FRONT TANK BEGAN LEAKING 2 MONTHS AGO, AND REAR TANK BEGAN LEAKING ON MARCH 19TH, 2001. *AK CONSUMER STATES REAR TANK RUSTED OUT BETWEEN SUPPORT BANDS AND TANK, FRONT TANK RUSTED OUT AT SEAMS, DEALER HAS REPLACED. *SLC
A PORTION OF FUEL FROM ONE TANK IS BEING RETURNED TO SECOND TANK ,CASUING FUEL LEAKAGE. A RECALL HAS BEEN ISSUED ON VEHICLE'S MAKE AND MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED DUE TO VIN. MANUFACTURER HAS BEEN NOTIFIED.*AK *SLC
FUEL WAS ERUPTING FROM MY REAR FUEL TANK, I SWITCHED TANKS WHICH (TEMPORARLY) SOLVED THE PROBLEM. 1 WEEK LATER MY TRUCK STALLED AND WOULD NOT START. HAD IT TOWED TO VANCOUVER FORD IN VANC. WA AND $995.78 WORTH OF REPAIR/SERVICE CHARGES; JEREMY Z. SERVICE ADVISOR VERBALIZED THAT THERE IS NO CURRENT CAMPAIGN OR RECALL NOTICES RE THIS FUEL SPILLAGE PROBLEM AND MAJOR FUEL SUPPLY MALFUNCTION. THOUGH MY TRUCKS PROBLEMS ARE ACCURATELY DESCRIBED IN DETAIL AS STATED FOR NHTSA CAMPAIGNS 93V125000 AND 00V424000 I STRONGLY BELIEVE THAT MY VEHICLE SHOULD QUALIFY.*AK
FUEL TANKS LEAKED AND VALVES BETWEEN TANKS FAILED CAUSING GAS TO BE PUMPED OUT OF THE SIDE OF THE TRUCK EVERY TIME THE VEHICLE WAS STARTED.I CALLED FORD AND THEY SAID THAT OTHER VEHICLES WERE RECALLED FOR THE SAME REASON BUT DENIED RESPONSIBILITY AND REFUSED TO FOREWARD MY REQUEST*AK
DUAL FUEL TANKS WOULD HAVE AN OVERFLOW WHEN FUEL GOES FROM ONE TANK TO ANOTHER. ENGINE CHECK LIGHT WOULD COME ON. VEHICLE WAS CHECKED WITH MANUFACTURER'S REPRESENTATIVE, BUT NO RECALLS WERE FOUND.*AK
VEHICLE IS SHOWING THE SAME SYMPTOMS AS DESCRIBED IN RECALL 00V424000. DEALERSHIP INFORMED CONSUMER THAT HIS VEHICLE WAS NOT A PART OF RECALL. *AK
A PORTION OF UNUSED FUEL FROM ONE TANK IS BEING RETURNED TO SECOND TANK, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON MAKE/MODEL; HOWEVER, THIS VEHICLE WAS NOT INCLUDED DUE TO VIN. MANUFACTURER HAS BEEN NOTIFIED.*AK RECALL NUMBER 93V125. *SLC
WHILE FILLING FIRST TANK FUEL WOULD TRAVEL TO SECOND TANK AND SPILL OUT. *AK BOTH PUMPS WERE REPLACED UNDER WARRANTY. ALSO, THE OXYGEN SESOR WAS REPLACED AND THE PLUG WIRES WERE REROUTED. *YH
SAME PROBLEM AS IN RECALL 93V125000, CONSUMER HAD BEEN SMELLING GASOLINE. ALSO, VEHICLE LEAKING GAS. WENT TO DEALER TO INQUIRE ABOUT RECALL, DEALER SAID NO RECALL.*AK
WITHIN 60,000 MILES OIL PAN HAS PREMATURELY RUSTED, CAUSING OIL LEAKAGE. PLEASE GIVE ANY FURTHER DETAILS.*AK
SAME PROBLEM AS IN RECALL 93V125000, VEHICLE NOT INCLUDED ALTHOUGH IT HAD SAME PROBLEM. *AK
FRONT FUEL TANK LEAKING. HAVE SPOKEN TO SEVERAL OTHER FORD TRUCK OWNERS WITH THE SAME PROBLEM.*AK
EXPERIENCED SAME PROBLEM AND SYMPTOM AS RECALL 00V424000 WITH FUEL TANK OVERFILLING AND SPILLAGE. *AK
TRANSMISSION SHIFTS VERY HARSHLY INTO REVERSE AND SOMETIMES SKIPS THIRD GEAR.*AK
NO SUMMARY LISTED FOR ABOVE VEHICLE. *AK
IF THERE IS MORE THAN A HALF A TANK, FUEL WILL LEAK TO GROUND.*AK *SLC
FUEL TRANSFERING FROM ONE TANK TO THE OTHER COUSING FUEL TO LEAK OUT. *AK
Reading these
NHTSA publishes every complaint as the owner wrote it and investigates only a fraction. Spelling, capitalisation and judgement are the filer’s own. What carries weight is repetition: the same component failing the same way across many filings, and whether the manufacturer eventually opened a recall for it.