Page 5 of 10 · complaints 201–250 of 470

1992 Ford F-150 complaints

Owner reports filed with NHTSA about this vehicle, newest first and reproduced as filed. They are unverified accounts: one proves nothing, and a pattern across many is the thing worth reading. Back to the full 1992 record →

Electrical System › Alternator/Generator/RegulatorFire
Filed Mar 28, 2000TX

WHILE DRIVING ALTERNATOR OVERHEATED, CAUSING AN UNDERHOOD FIRE. CONSUMER PUT THE FIRE OUT. DEALER HAS NOT BEEN CONTACTED. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Mar 17, 2000WV

A MALFUNCTION WITHIN THE CHECK VALVE AND THE FUEL PUMP ASSEMBLY CAUSES UNUSED FUEL TO TRANSFER FROM ONE TANK TO THE SECOND, CAUSING FUEL LEAKAGE. *AK

Parking Brake › Conventional › Mechanical › Linkage and Cable
Filed Mar 17, 2000IL

THE PARKING BRAKE EQULIZER IS A C CHANNEL THAT CONNECTS THE CABLE FROM THE PEDAL ASSEMBLY TO THE TWO CABLES GOING TO THE REAR WHEELS. I HAVE HAD TWO EQULIZERS FAIL. THE FIRST ONE AT38000 MILES. THE SECOND AT 125000 MILES OR ABOUT 80000 MILES LATER. IN BOTH CASES THE EQULIZER BROKE WHERE THE PEDAL ASSEMBLY ATTACHES TO THE EQULIZER. THE TRUCK WAS PARKED WITH THE PARKING BRAKE APPLIED AND THE TRANSMISSION IN REVERSE. THE TRUCK HAS A STANDARD TRANSMISSION. THE NEXT MORNING I FOUND THE PARKING BRAKE PEDAL WOULDN'T MOVE WHEN RELEASED. I LOOKED UNDER THE TRUCK. THE BRAKE CABLE WAS LOOSE AND LAYING ON THE GROUND.THE ONLY THING KEEPING MY TRUCK FROM ROLLING DOWN MY DRIVE WAS THE TRANSMISSION. BOTH TIMES THE EQULIZER FAILED UNDER SIMILAR CIRCUMSTANCES. THIS IS A VERY UNSAFE CONDITION. I THINK THE EQULIZER SHOULD BE MADE FROM HEAVIER STEEL TO LAST THE LIFE OF THE VEHICLE. *AK

Parking Brake › Conventional › Mechanical › Linkage and Cable
Filed Mar 15, 2000IL

THIS PART CONNECTS THE PARKING BRAKE PEDAL TO THE TWO CABLES THAT GO TO THE REAR WHEELS. THE BRAKE WAS APPLIED AND THEN THE PART FAILED LEAVING THE TRUCK FREE TO ROLL. THIS IS THE SECOND EQULIZER I HAVE HAD. THE FIRST ONE FAILED IN THE SAME PLACE AND THE SAME WAY. I DON'T THINK IT IS MADE OUT OF HEAVY ENOUGH STEEL. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Mar 13, 2000MI

A PORTION OF UNUSED FUEL PASSES FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, CAUSING AN OVERFLOW OF FUEL AT THE FILLER NECK. ALSO, RECALL 93V125000 DEALS WITH THE SAME PROBLEM. HOWEVER, THIS VEHICLE IS NOT INCLUDED IN THE RECALL DUE TO VIN. PLEASE PROVIDE ANY FURTHER DETAILS. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Mar 13, 2000CA

A PORTION OF UNUSED FUEL FROM ON TANK IS BEING RETURNED TO THE SECOND TANK, CAUSING FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON THE VEHICLE'S MAKE AND MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Mar 13, 2000FL

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE FRONT FILLER CAP STARTS LEAKING FUEL. CONTACTED DEALER AND MANUFACTURER.*AK *ML

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Mar 10, 2000TN

A PORTION OF UNUSED FUEL FROM ONE TANK IS BEING RETURNED TO THE SECOND TANK, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON THE VEHICLE'S MAKE AND MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. MANUFACTURER WILL BE NOTIFIED. TRANSMISSION ALSO FAILED AT 47000 MILES AND HAD TO BE REPLACED . *AK *ML

Power Train › Automatic Transmission
Filed Mar 10, 2000MO

WHEN DRIVING FROM A STOPPED POSITION VEHICLE WILL SHIFT INTO NEUTRAL. COMPUTER IS RESPONSABLE FOR THIS. TO RESET THE BATTERY CABLE, IT HAS TO BE UNHOOKED. DEALER HAS BEEN CONTACTED. *AK

Fuel System, Gasoline › Storage › Tank Assembly
Filed Mar 6, 2000GA

THE RECALLED CHECK VALVE FAILED CAUSES PORTIONS OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, WHEN THIS OCCURS THE CAPACITY OF THE SECOND TANK IS EXCEEDED, CAUSING FUEL SPILLAGE, THE ORIGINAL RECALL DID NOT FIX THE PROBLEM. NLM

Fuel System, Gasoline › Storage › Tank Assembly
Filed Feb 28, 2000WA

PRIOR TO RECALL FUEL TANK FAILED(93V-125).YH

Fuel System, Gasoline › Storage › Tank Assembly
Filed Feb 9, 2000CT

ON DEC. 26, 1999 IREAD IN THE HARTFORD COURANT ABOUT AN INVESTIGATION ON FORD PICK-UP TRUCKS F-150 FOR THE YEARS 1990-1993 FOR FUEL TANK LEAKAGES. IHAD TO PAY $538.55 TO HAVE ONE OF MY FUEL TANKS REPLACED DUE TO A LEAK ON 5-24-99. WHEN I CALLED FORD ON 12-27-1999 , THEY COULD NOT HELP ME, AND SAID MY VIN NUMBER WAS NOT THE NUMBERS RECALLED. I CALLED YOUR WASHINGTON PHONE NUMBER AND THE LADY TOLD ME TO FILL OUT THIS FORM ON THE INTERNET. PLEASE ADVISE ME. I BELIEVE MY TRUCK IS AMONG THE TRUCKS YOU ARE INVESTIGATING. THE FUEL TANK WAS REPLACED BY WILLIAMS FORD IN WEST HARTFORD CT. AND WE HAVE A COPY OF THE BILL IF NEEDED. PLEASE LET US KNOW THE RESULTS OF YOUR INVESTIGATION. I'M STILL SKEPITCAL IN DRIVING MY TRUCK IN FEAR THE UNREPAIRED TANK COULD LEAK. THANK YOU VERY MUCH FOR YOUR HELP WITH THIS MATTER. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Feb 8, 2000NJ

THE FRONT TANK DRAWS FUEL FROM THE BACK TANK, WHICH OVERFLOWS THE FRONT TANK. THIS CAUSES FUEL TO SPILL ONTO THE GROUND. TRUCK WAS TAKEN TO THE DEALERSHIP. DEALER STATED THAT TRUCK WAS NOT INCLUDED IN RECALL # 93V125000 FUEL: FUEL TANK: AUXILIARY SELECTOR AND SWITCH, AND WOULD NOT BE REPAIRED FREE. PLEASE PROVIDE ANY FURTHER INFORMATION. *AK

Fuel System, Gasoline
Filed Feb 8, 2000IL

FUEL WAS RETURNING TO THE WRONG TANK, CAUSING OVERFLOW ONTO THE GROUND, REPAIRED THEN FAILED AGAIN. *MJS

Electrical System › IgnitionFire
Filed Jan 28, 2000NV

VEHICLE WAS PARKED FOR OVER AN HOUR WHEN IT CAUGHT FIRE AROUND THE DASH OR WITHIN THE ENGINE COMPARTMENT. VEHICLE WAS TOTALED. CONTACTED FORD, BUT THEY WERE UNWILLING TO HELP PAY FOR COST OF NEW VEHICLE. *AK *ML

Fuel System, Gasoline › Storage › Auxillary Tank
Filed Jan 22, 2000KS

EA99032, DUAL FUEL TANK CROSSFLOW/LEAKAGE; THE REAR TANK WAS REPLACED BECAUSE FUEL WAS LEAKING FROM THE BOTTOM REAR OF THE TANK. OWNER DISCOVERED FUEL LEAKAGE AFTER TRUCK WAS PARKED IN THE GARAGE OVER NIGHT. *AK

Fuel System, Gasoline
Filed Jan 22, 2000NY

GAS MOVES FROM REAR TO THE FRONT TANK DUE TO FUEL SYSTEM MALFUNCTIONING. YH

Fuel System, Gasoline › Storage › Tank Assembly
Filed Jan 18, 2000OH

RECALL WORK COMPLETED ON 93V-125 (FUEL TANK ASSEMBLY), THE VEHICLE DID NOT EXPERIENCE FAILURE PRIOR TO RECALL HOWEVER AFTER REPAIR THE FAILURE WAS EXPERIENCED. NLM MJS

Fuel System, Gasoline
Filed Jan 18, 2000MI

DUAL GAS TANK FUEL SYSTEM OVER PRESSURIZED CAUSING GAS TO TRANSFER FROM ONE TANK TO ANOTHER RESULTING IN SPILLAGE. NLM

Fuel System, Gasoline › Delivery › Fuel Pump
Filed Jan 13, 2000FL

FUEL PUMP ASSEMBLY/CHECH VALVE FAILED CAUSING FUEL TO COME STREAMING OUT WHEN CONSUMER LOOSENED GAS CAP. NLM

Electrical System › Alternator/Generator/RegulatorFire
Filed Jan 11, 2000FL

WHILE DRIVING BATTERY LIGHT CAME ON. OWNER PULLED OVER AND OPENED THE HOOD, AND FLAMES WERE COMING FROM IT DUE TO ALTERNATOR CATCHING ON FIRE. DEALER HAS VEHICLE CURRENTLY. *AK *ML

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Jan 10, 2000CT

RECALL # 93V125000 FUEL: FUEL TANK ASSEMBLY: AFTER BOTH TANKS WERE FILLED OWNER DROVE TRUCK ABOUT 2 MILES FOR HOME. OWNER OPENED REAR TANK TO FILL WITH DRY GAS, AND ABOUT 5 GALLONS OF GAS FLEW OUT OF THE TANK ALL OVER OWNER AND GROUND. AFTERING SWITCHING TO THE FRONT TANK, OWNER DROVE ABOUT 8 MILES, MADE A STOP, AND NOTICED GAS SPILLING FROM THE FRONT TANK. TRUCK WAS DRIVEN TO THE DEALERSHIP. A FUEL PUMP WAS ORDERED FOR THE FRONT TANK. THE PUMP HAS NOT BEEN REPLACED. PLEASE PROVIDE ANY FURTHER INFORMATION. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Jan 10, 2000OH

A PORTION OF UNUSED FUEL FROM ONE TANK IS RETURNING FUEL TO THE SECOND TANK, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON THE VEHICLE'S MAKE AND MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. MANUFACTURER HAS BEEN NOTIFIED. *AK

Fuel System, Gasoline › Delivery › Fuel Pump
Filed Jan 10, 2000IL

FUEL PUMPS FAILED CAUSING GAS TO SPRAY AT GOOSE NECK. VEHICLE WAS RECALL IN 1993 BUT ORIGINAL DEALER HAS NO RECORD OF REPAIR (TIME LAPSE). *NLM

Engine and Engine Cooling › Cooling System
Filed Jan 3, 2000SC

WHILE DRIVING ON THE HIGHWAY, THE VEHICLE CUT OFF / COMPLETELY STOP WORKING. DEALER WORKED ON VEHCILE AND PUT A NEW THERMOSTAT IN THE MOTOR TO CORRECT PROBLEM. WHILE IN THE PROCESS OF REPAIR, DEALER SMELLED GASOLINE DUE TO ONE TANK PUMPING THROUGH THE OTHER WHICH COULD HAVE CAUSE A SPILLAGE / FIRE HAZARD. *AK *YC

Fuel System, Gasoline › Storage › Tank Assembly
Filed Jan 3, 2000VA

CONSUMER RECEIVED RECALL 93V125000/ MFR 93S68 REGARDING THE FUEL TANK, WORK WAS DONE IN 1993. CONSUMER IS HAVING PROBLEMS WITH A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP. THIS PROBLEM IS THE SAME IDENTICAL PROBLEM LISTED IN THE RECALL. PLEASE PROVIDE ANY FURTHER DETAILS. *AK

Fuel System, Gasoline › Fuel Injection SystemFire
Filed Jan 3, 2000KS

NO SUMMARY LISTED FOR ABOVE VEHICLE. *AK

Engine and Engine Cooling › Exhaust System › Emission Control › Crankcase (pcv)
Filed Jan 3, 2000MI

BAD CHECK VALVE CAUSED THE FUEL PUMP TO FAIL RESUTING IN FUEL TO OVER FLOW FROM THE TANK (93V-125). YH

Fuel System, Gasoline › Storage › Tank Assembly
Filed Dec 30, 1999NY

FUEL TANK LEAKS. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Dec 28, 1999AZ

TRUCK HAS DUAL FUEL TANKS. WHEN RUNNING OFF OF THE FRONT TANK IT WILL PUMP GAS TO THE REAR TANK, OVERFILLING IT AND CAUSING A FIRE HAZARD. RECALL #93V125000 SHOULD COVER THIS PROBLEM BUT FORD SAYS MY TRUCK VIN IS NOT INCLUDED AND REFUSES TO ADDRESS THIS VERY DANGEROUS DEFECT. TRUCK WAS PURCHASED USED IN JUNE 1999 FROM A PRIVATE PARTY AND HAS HAD THIS PROBLEM SINCE I PURCHASED IT. PLEASE TRY TO MAKE FORD ADDRESS THIS ISSUE. THANK YOU. *AK

Fuel System, Gasoline › DeliveryFire
Filed Dec 28, 1999MD

IN SEPTEMBER OF 1998 MY 1992 F-150 CAUGHT FIRE FOR NO APPARENT REASON. I WAS OUT DRIVING, WHEN I GOT TO MY DESTINATION I PARKED. A FEW HOURS LATER MY TRUCK WAS ON FIRE. I DID NOT HERE ABOUT A RECALL ON THE FUEL SYSTEM UNTILL A WEEK AGO. I AM SENDING THIS TO YOU IN CASE THERE IS SOME RELATION BETWEEN THE FIRE AND THE RECALL. ANY INFORMATION YOU CAN SEND BACK WOULD BE GREATLY APPRECIATTED.

Fuel System, Gasoline › Storage › Tank Assembly
Filed Dec 27, 1999CT

ON DEC 26, 1999 I READ IN THE HARTFORD COURANT ABOUT AN INVESTIGATION ON FORD PICK-UP TRUCKS F-150 FOR THE YEARS 1990-1993 FOR FUEL TANK LEAKAGES. I HAD TO PAY $538.55 TO HAVE MY FUEL TANK REPLACED DUE TO A LEAK ON 5-24-99. WHEN I CALLED FORD TODAY, 12-27-99, THEY COULD NOT HELP ME, AND SAID MY VIN NUMBER WAS NOT THE NUMBERS RECALLED. I CALLED YOUR WASHINGTON PHONE NUMBER AND THE LADY TOLD ME TO FILL OUT THIS FORM ON THE INTERNET. PLEASE ADVISE ME. I BELIEVE MY TRUCK IS AMONG THE TRUCKS YOU ARE INVESTIGATING. THE FUEL TANK WAS REPLACED BY WILLIAMS FORD IN WEST HTFD,, AND WE HAVE A COPY OF THE BILL IF NEEDED. PLEASE LET US KNOW THE RESULTS OF YOUR INVESTIGATION. THANK YOU VERY MUCH FOR YOUR HELP WITH THIS MATTER. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Dec 24, 1999IL

FUEL FROM REAR FUEL TANK IS PUMPED INTO FRONT TANK, CAUSING FRONT TANK TO OVER FLOW. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Dec 23, 1999IL

NHTSA RECALL # 93V125 000: FUEL TANK ASSEMBLY AND EA # 99 032: DUAL FUEL TANK CROSSFLOW/ LEAKAGE: VEHICLE EXPERIENCES A PROBLEM WITH PORTION OF THE UNUSED FUEL FROM ONE TANK RETURNED TO SECOND TANK. WHEN THIS OCCURRED THE SECOND TANK EXCEEDED, CAUSING FUEL SPILLAGE. SPILLAGE COULD RESULT IN A FIRE WHEN EXPOSED TO A SOURCE OF IGNITION. ON TWO OCCASIONS, THIS INCIDENT HAS OCCURRED. FIRST TIME, REPAIRS WERE DONE UNDER WARRANTY. CURRENTLY, REOCCURRING PROBLEM IS BEING REPAIRED AT CONSUMER'S COST WITH THE SAME CHECK VALVE REPLACMENT. COULD NHTSA SHARE SOME LIGHT ON THE DEFECTIVE CHECK VALVE. *AK

Fuel System, Gasoline › Storage › Tank Assembly
Filed Dec 22, 1999MA

WHILE VEHICLE WAS PARKED IN DRIVEWAY NOTICED FUEL LEAKING, PUDDLE ON GROUND. MANUFACTURER HAS BEEN NOTIFIED. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Dec 22, 1999OH

EA99032, DUAL FUEL TANK CROSSFLOW/LEAKAGE; WHEN BOTH FUELTANKS ARE FILLED, THE FUEL FLOWS TO THE TANK THAT IS NOT BEING USED, CAUSING THE FUEL TO SPILL ONTO THE GROUND. DEALER KNOWS THAT THIS IS A VERY COMMON PROBLEM. THE PROBLEM HAS NOT BEEN CORRECTED. *AK *ML

Fuel System, Gasoline › Storage › Auxillary Tank
Filed Dec 21, 1999MO

SECOND FUEL TANK CRACKED, CAUSING A FUEL LEAK WHICH MAY RESULT IN A FIRE. DEALER NEEDS TO REPLACE THE REAR FUEL TANK. *AK

Fuel System, Gasoline › Storage › Tank Assembly
Filed Dec 21, 1999NC

FUEL TRANSFER SYSTEM FAILS. GAS SPILLS INTO THE ENGINE COMPARTMENT. I HAVE HAD THE RECALL WORK DONE. *AK

Power Train › Manual Transmission
Filed Dec 16, 1999LA

VEHICLE JERKS WHEN CHANGING GEARS AT ABOUT 35 AND 50 MPH BUT DEALER IS UNABLE TO FIX THE PROBLEM. NLM

Fuel System, Gasoline › Storage › Tank Assembly
Filed Dec 1, 1999VA

PRIOR TO RECALL AND AFTER RECALL WORK PERFORMED ON THE FUEL TANK, CONSUMER HAS EXPERIENCED SEVERAL OCCASIONS OF THE GAS LEAKING OUT OF THE FUEL FILLER AREA AND PROBLEMS WITH FUEL SYSTEM DUE TO FAILURE. MJS (93V-125)

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Nov 29, 1999GA

A PORTION OF UNUSED FUEL FROM ONE TANK IS RETURNING TO THE SECOND TANK, CAUSING THE CAPACITY OF THE SECOND TANK TO BE EXCEEDED, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON VEHICLE MAKE/MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED. DEALER AND MANUFACTURER HAVE BEEN NOTIFIED. *AK

Vehicle Speed Control
Filed Nov 23, 1999CD

CRUISE CONTROL MALFUNCTIONS, STICKING WHILE IN USE ON OCCASIONS. YH

Electrical System › Alternator/Generator/RegulatorFire
Filed Nov 17, 1999TX

CONNECTION WITHIN THE WIRNING HARNESS WHICH IS ATTACHED TO THE ALTERNATOR TYPE IAR, THE PLASTIC CONNECTION SHORTED OUT, CAUSING AN ELECTRICAL FIRE. *AK

Latches/Locks/Linkages › Doors › Latch
Filed Nov 1, 1999IA

THE INSIDE DOOR LATCH WILL NOT OPEN THE DOOR FROM THE INSIDE CAUSING THE DRIVER TO ROLL THE WINDOW DOWN AND OPEN THE DOOR FROM THE OUTSIDE. NLM

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Oct 25, 1999VA

DUAL TANKS : THE FRONT FUEL TANK WOULD PUMP GAS INTO THE REAR TANK, SPILLING FUELON THE GROUND. CONSUMER HAS TAKEN VEHICLE TO THE DEALERSHIP SEVERAL TIMES. HAS HAD SEVERAL PARTS REPLACED, BUT VEHICLE IS STILL EXPERIENCING THE SAME PROBLEM OVER AND OVER. *AK

Service Brakes, Hydraulic › Antilock/Traction Control/Electronic Limited Slip
Filed Oct 17, 1999TN

THE ABS AND PARKING BRAKE LIGHTS REMAIN ON CONTINOUSLY. I HAVE TESTED ALL COMPONENTS ACCORDING TO CHILTONS AND CAN FIND NO DEFECTIVE PARTS, I BELIEVE IT IS A MANUFACTURERS DEFECT, IT IS IMPOSSIBLE TO KNOW IF THE BRAKES ARE FUNCTIONING PROPERLY. I HAVE FOUND A TSB THROUGH YOUR DATABASE BUT IT IS VAGUE, DOES MY VEHICLE POSE A SAFETY HAZARD? THIS VEHICLE IS COMPLETELY ORIGINAL, EXCEPT TIRES. PLEASE ADVISE. *AK

Fuel System, Gasoline › Storage › Tank Assembly
Filed Oct 14, 1999TX

RECALL 93V-125000/FUEL TANK ASSEMBL WAS RECEIVED AND REPAIRED. LATER, PROBLEM REAPPEARED, WAS NOT CORRECTED PRPERLY, RETURNED TO DEALER AND INFORMED CONSUMER THAT BOTH FUEL PUMPS IN TANK MALFUNCTION ED AND NEEDS REPLACING AT APPROX. $800 . CAN NHTSA PROVIDE INFORMATION ON THIS MATTE., IS DEALER STILL RESPONDSIBLE? YOUR HELP IN THIS MATTER IS NEEDED. *AK

Electrical System › Ignition › Switch
Filed Oct 7, 1999AZ

IGNITION SWITCH BECAME LOOSE, REPAIRED ON SEVERAL OCCASIONS HOWEVER CONTINUES TO BE LOOSE AND ABLE TO BE STARTED WITHOUT THE KEY. MJS

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Oct 6, 1999IL

THIS VEHICLE IS EQUIPPED WITH A DUAL VALVE GAS TANK WHICH HAS A SWITCH TO CHANGE FROM THE FRONT TANK TO THE REAR TANK. IN THE PROCESS OF SWITCHING TANKS THE FRONT TANK OVERFLOWED, CAUSING THE FUEL T SPILL OUT. DEALER HAS BEEN CONTACTED. *AK

Fuel System, Gasoline › Storage › Auxillary Tank › Selector Devices
Filed Sep 24, 1999MO

THE VEHICLE HAS TWO TANKS, WHEN THE VEHICLE IS SUPPOSED TO PUMP GAS INTO THE FUEL TANK IT IS PRODUCING GAS INTO THE WRONG TANK CAUSING GAS TO OVER FLOW OUT OF THE VEHICLE. MJS

Reading these

NHTSA publishes every complaint as the owner wrote it and investigates only a fraction. Spelling, capitalisation and judgement are the filer’s own. What carries weight is repetition: the same component failing the same way across many filings, and whether the manufacturer eventually opened a recall for it.

Full record for the 1992 Ford F-150 → · Every F-150 year → · How the figures are calculated →