NHTSA campaign 04V339000 · Part 573 safety recall report

Crane Carrier Company: Fuel System, Other › Storage › Tank Assembly › Pressure Relief Devices

Crane Carrier Company reported this defect to federal regulators on Jul 21, 2004 and put the number of vehicles at risk at 3. The repair is free for as long as the recall stands.

The defect

CERTAIN TRUCKS EQUIPPED WITH NEXGEN LIQUID NATURAL GAS (LNG) TANKS ARE BEING RECALLED. THE INTRODUCTION OF WATER INTO THE DISCHARGE SIDE OF BOTH THE PRIMARY AND SECONDARY RELIEF VALVES SIMULTANEOUSLY AND SUBSEQUENT FREEZING IN SERVICE CAN RENDER THE VALVES TEMPORARILY INOPERATIVE.

The risk

IF NOT INSPECTED THE RISK OF TANK OVER-PRESSURIZATION AND A CATASTROPHIC TANK RUPTURE CAN OCCUR, POTENTIALLY RESULTING IN SERIOUS INJURY OR DEATH.

The remedy

CRANE WILL PERFORM AN INSPECTION AND PROVIDE INSTRUCTIONS FOR ORDERING AND INSTALLING THE RETROFIT KIT. THE RECALL IS EXPECTED TO BEGIN DURING JULY 2004. OWNERS SHOULD CONTACT CRANE AT 918-832-7305.

2 model years covered

Newest first
VehicleComplaintsRecallsFiresCrashes
2003 Crane LCF0300
1997 Crane Coe0300

What this page is, and what to do next

A recall is not an opinion. It is a Part 573 report a manufacturer is required by federal law to file once it decides a defect poses an unreasonable risk to safety, and it commits them to repairing the vehicle at no cost to the owner. The three passages above are the manufacturer’s own wording as published by NHTSA.

This page describes the campaign. It cannot tell you whether one particular car has already been through the shop — that is tracked by VIN, and only the manufacturer knows it. Check yours at nhtsa.gov/recalls or with a franchised dealer, quoting campaign number 04V339000.

Full record for the 2003 Crane LCF → · Recalls carrying a do-not-drive advisory → · Where this data comes from →