NHTSA campaign 03V275000 · Part 573 safety recall report

Utilimaster Corporation: Electrical System › Wiring › Fuses and Circuit Breakers

Utilimaster Corporation reported this defect to federal regulators on Jul 29, 2003 and put the number of vehicles at risk at 4,001. The repair is free for as long as the recall stands.

The defect

ON CERTAIN WALK-IN VANS, A FUSE WAS INSTALLED BY FORD. HOWEVER, UTILIMASTER INSTALLED A WIRE. THE FUSE IS NOT COMPATIBLE WITH THE WIRE GAUGE INSTALLED BY UTILIMASTER.

The risk

SHOULD A FAILURE OCCUR IN A VEHICLE COMPONENT SUCH AS A FAN, HEATED MIRROR AND/OR OTHER IGNITION-HOT OPTION, THE INSULATION AROUND THE WIRING TO THE FAN COULD MELT.

The remedy

OWNERS WILL BE PROVIDED WITH A REPLACEMENT FUSE. OWNER NOTIFICATION BEGAN OCTONER 1, 2003. OWNERS SHOULD CONTACT UTILIMASTER AT 1-800-582-3454.

What this page is, and what to do next

A recall is not an opinion. It is a Part 573 report a manufacturer is required by federal law to file once it decides a defect poses an unreasonable risk to safety, and it commits them to repairing the vehicle at no cost to the owner. The three passages above are the manufacturer’s own wording as published by NHTSA.

This page describes the campaign. It cannot tell you whether one particular car has already been through the shop — that is tracked by VIN, and only the manufacturer knows it. Check yours at nhtsa.gov/recalls or with a franchised dealer, quoting campaign number 03V275000.

Full record for the 2001 Utilimaster Walk-In Van → · Recalls carrying a do-not-drive advisory → · Where this data comes from →