No owner complaints are on file for this vehicle. It has been recalled 4 times.
4 safety recalls
Part 573 reports
Fuel System, Diesel › Fuel Injection System › Fuel Rail21V790000
Filed Oct 11, 2021245 vehiclesHme, Inc.
Defect. HME, Inc. (HME) is recalling certain 2017-2020 Ahrens-Fox model 34 Type 3, Rescue, Pumper, Tanker, Aerial, CommFox, WolfSA Tanker, 1871-SFO, 1871-W, 1871-Spectr, and AF1 fire trucks. The sealing washer may not seat correctly in the pilot boreholes, allowing the high-pressure fuel rail assembly to leak.
Risk. A fuel leak in the presence of an ignition source increases the risk of a fire.
Remedy. Dealers will inspect the rail threads and fuel lines, and replace the rail as necessary, free of charge. Owners were notified on January 20, 2021. Owners may contact HME's customer service at 1-616-534-1463.
Defect. HME, Inc. (HME) is recalling certain 2016-2021 AF1 and 1871 vehicles. The self-leveling function may malfunction, causing the aerial bucket to move beyond the level position.
Risk. Unexpected movement of the aerial bucket increases the risk of an injury.
Remedy. HME will reprogram the aerial controls and modify the hydraulic system, free of charge. Owner notification letters were mailed on June 2, 2021. Owners may contact HME customer service at 1-616-534-1463.
Electrical System › Wiring21V282000
Filed Apr 22, 202130 vehiclesHme, Inc.
Defect. HME, Inc. (HME) is recalling certain 2013-2021 AF1, 1871, and SFO vehicles. Insufficient voltage and/or cracked wiring insulation may cause the aerial controls system to fail.
Risk. Exposed wires can create a shock risk to the vehicle operator.
Remedy. HME will inspect and service all affected vehicles, including installation of new and replacement aerial components, free of charge. The manufacturer has not yet provided a schedule for recall notification. Owners may contact HME customer service at 1-616-534-1463.
Electrical System › Wiring › Fuses and Circuit Breakers20V104000
Filed Feb 24, 2020174 vehiclesHme, Inc.
Defect. HME, Inc. (HME) is recalling certain 2016-2020 AF1, 1871 and SFO emergency vehicles. The fuse box may be missing an O-Ring seal, potentially allowing moisture or contaminants into the fuse box.
Risk. If moisture or contaminants enter the fuse box, the fuse box may overheat or malfunction, increasing the risk of a crash.
Remedy. HME will notify owners and will provide replacement fuse boxes, free of charge. The recall began May 18, 2020. Owners may contact HME customer service at 1-616-534-1463.
No unusual pattern of severe incidents in the complaint record.
Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.
Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.
Most recent recall on file: Oct 11, 2021. Source: NHTSA Office of Defects Investigation.