2001 Forest River Tsunami

Routine

No owner complaints are on file for this vehicle. It has been recalled 3 times.

3 safety recalls

Part 573 reports
Equipment › Recreational Vehicle/Trailer11V152000
Filed Mar 1, 201138 vehiclesForest River, Inc.

Defect. FOREST RIVER IS RECALLING CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH 1200-SERIES NORCOLD REFRIGERATORS. THE POPULATION OF REFRIGERATORS BEING ADDRESSED CONTAINS EITHER A SENSING ALGORITHM OR THERMAL SWITCH TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED IN ORDER TO PREVENT A POTENTIAL FIRE. THE RESPONSE TIMES OF THE SENSOR ALGORITHM AND THERMAL SWITCH DEVICES TO STOP POWER ARE NOT SUFFICIENT.

Risk. THE SENSING ALGORITHM OR THERMAL SWITCH INSTALLED TO SHUT OFF POWER TO THE REFRIGERATOR WHEN HIGH TEMPERATURES ARE DETECTED DUE TO A POSSIBLE HYDROGEN GAS LEAK MAY NOT SHUT OFF IN SUFFICIENT TIME TO PREVENT A FIRE.

Remedy. FOREST RIVER IS WORKING WITH NORCOLD TO IDENTIFY AND NOTIFY ANY AFFECTED OWNERS. OWNERS WILL BE INSTRUCTED TO CONTACT NORCOLD DEALERS TO RECEIVE THE REMEDY FREE OF CHARGE. PLEASE SEE NORCOLD'S DEFECT REPORT 10E-049 FOR ADDITIONAL INFORMATION. THE SAFETY RECALL BEGAN ON MARCH 14, 2011. OWNERS MAY CONTACT NORCOLD AT 1-800-767-9101.

Equipment › Recreational Vehicle/Trailer08V277000
Filed Jun 20, 20081 vehiclesForest River, Inc.

Defect. FOREST RIVER IS RECALLING 1 MY 2001 TSUNAMI CLASS A DIESEL PUSHER MOTOR HOME MOTOR HOMES EQUIPPED WITH A NORCOLD REFRIGERATOR. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE LIQUID SOLUTION TO SLOWLY LEAK.

Risk. EXTENDED OPERATION OF A LEAKING COOLING UNIT COULD LEAD TO A FIRE FROM GAS WHICH MIGHT ESCAPE.

Remedy. FOREST RIVER IS WORKING WITH NORCOLD TO REPAIR THESE REFRIGERATORS. NORCOLD WILL PROVIDE THERMAL SWITCH KITS TO OWNERS ALONG WITH THE NECESSARY FORMS AND INSTRUCTIONS. THE RECALL IS EXPECTED TO BEGIN DURING JULY OR AUGUST 2008. OWNERS MAY CONTACT NORCOLD AT 1-800-767-9101 OR FOREST RIVER AT 1-574-389-4600.

Equipment › Recreational Vehicle/Trailer07V085000
Filed Mar 5, 2007128,000 vehiclesForest River, Inc.

Defect. CERTAIN RECREATIONAL VEHICLES EQUIPPED WITH A TWO-DOOR REFRIGERATOR, MANUFACTURED BY THE DOMETIC CORPORATION, MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.

Risk. RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.

Remedy. FOREST RIVER WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST YOU IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR FOREST RIVER AT 1-574-389-4600,

Across model years

Worst on record: 2005
YearComplaintsRecallsFiresDeathsAssessment
20080100Routine
20070100Routine
20060300Routine
20052400Routine
20040400Routine
20030500Routine
20020400Routine
2001 — this page0300Routine
20000200Routine
19990100Routine
19980100Routine
19970100Routine

Compare every Tsunami year →

Reading this record

No unusual pattern of severe incidents in the complaint record.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.

Most recent recall on file: Mar 1, 2011. Source: NHTSA Office of Defects Investigation.