2015 Spartan DR

Routine

No owner complaints are on file for this vehicle. It has been recalled 1 time.

1 safety recall

Part 573 reports
Service Brakes, Air14V747000
Filed Nov 24, 20141,059 vehiclesSpartan Motors, Inc.

Defect. Spartan Motors, Inc. (Spartan) is recalling certain model year 2013-2015 Gladiator, DR, K2, K3, MetroStar, MM, and NVS vehicles manufactured December 14, 2011, to October 21, 2014, equipped with certain Wabco Quick Release Valves with Double Check. In the affected valves, the rubber diaphragm may be damaged by sharp edges on the valve seat ribs, reducing the available air pressure in the air tanks.

Risk. The reduced air pressure levels may reduce braking performance and/or the parking brakes could reapply, increasing the risk of a crash.

Remedy. Spartan will notify owners, and dealers will inspect and replace the valve, free of charge. The recall began January 22, 2015. Owners may contact Spartan customer service at 1-517-543-6400. Spartan's number for this recall is 14021.

Across model years

Worst on record: 2015
YearComplaintsRecallsFiresDeathsAssessment
2015 — this page0100Routine
20140100Routine
20130100Routine

Compare every DR year →

Reading this record

No unusual pattern of severe incidents in the complaint record.

Complaint counts track how many cars were sold and how long they have been on the road as much as they track quality. A common model from 2013 has had a decade to accumulate reports; a rare one from last year has not. The signal worth weighing is in the severity columns, in whether the same component keeps appearing, and in whether the manufacturer eventually opened a recall for it.

Recall repairs are free for as long as the recall stands. Check whether a specific car still has open work at NHTSA's VIN lookup.

Most recent recall on file: Nov 24, 2014. Source: NHTSA Office of Defects Investigation.