Transit Bus International: Fuel System, Other › Storage › Tank Assembly › Pressure Relief Devices
Transit Bus International reported this defect to federal regulators on Aug 14, 1995 and put the number of vehicles at risk at 94. The repair is free for as long as the recall stands.
The defect
UPON EXPOSURE TO IMPURITIES IN THE NATURAL GAS FUEL IN COLD WEATHER, AN INTERNAL O-RING ON THESE DEVICES CAN BLISTER DURING DECOMPRESSION AFTER "FAST-FILL" REFUELING RESULTING IN SEAL LEAKAGE.
The risk
INTERNAL DAMAGE TO THE O-RING SEAL COULD CAUSE ARELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.
The remedy
MIRADA IS CONDUCTING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. DEALERS WILL REPLACE RECALLED UNITS WITH NEW DEVICES THAT ARE NOT SUSCEPTIBLE TO O-RING DAMAGE FROM NON-METHANE COMPONENTS OF THE GAS SUPPLY WHEN THE DEVICES ARE DEVELOPED.
4 model years covered
Newest first| Vehicle | Complaints | Recalls | Fires | Crashes |
|---|---|---|---|---|
| 1994 Tbii T80206 | 0 | 1 | 0 | 0 |
| 1994 Tbii T80208 | 0 | 1 | 0 | 0 |
| 1993 Tbii T80206 | 0 | 1 | 0 | 0 |
| 1993 Tbii T80208 | 0 | 1 | 0 | 0 |
What this page is, and what to do next
A recall is not an opinion. It is a Part 573 report a manufacturer is required by federal law to file once it decides a defect poses an unreasonable risk to safety, and it commits them to repairing the vehicle at no cost to the owner. The three passages above are the manufacturer’s own wording as published by NHTSA.