NHTSA campaign 04V308000 · Part 573 safety recall report

Gillig Corporation: Fuel System, Other

Gillig Corporation reported this defect to federal regulators on Jun 23, 2004 and put the number of vehicles at risk at 3. The repair is free for as long as the recall stands.

The defect

CERTAIN LOW FLOOR BUSES POWERED BY A GASEOUS HYDROGEN FUEL SYSTEM. THESE TRANSDUCERS WERE MADE OF 17-4 PH STAINLESS STEEL MATERIAL WHICH MAY BE SUSCEPTIBLE TO EMBRITTLEMENT IN A HIGH-PRESSURE HYDROGEN APPLICATION ENVIRONMENT.

The risk

EMBRITTLEMENT COULD POTENTIALLY LEAD TO A TRANSDUCER DIAPHRAGM FAILURE.

The remedy

DEALERS WILL REPLACE THE TRANSDUCER. THE RECALL BEGAN JULY 12, 2004. OWNERS SHOULD CONTACT GILLIG AT 1-510-785-1500.

2 model years covered

Newest first
VehicleComplaintsRecallsFiresCrashes
2004 Gillig Low Floor0800
2003 Gillig Low Floor1900

What this page is, and what to do next

A recall is not an opinion. It is a Part 573 report a manufacturer is required by federal law to file once it decides a defect poses an unreasonable risk to safety, and it commits them to repairing the vehicle at no cost to the owner. The three passages above are the manufacturer’s own wording as published by NHTSA.

This page describes the campaign. It cannot tell you whether one particular car has already been through the shop — that is tracked by VIN, and only the manufacturer knows it. Check yours at nhtsa.gov/recalls or with a franchised dealer, quoting campaign number 04V308000.

Full record for the 2004 Gillig Low Floor → · Recalls carrying a do-not-drive advisory → · Where this data comes from →