NHTSA campaign 03V089000 · Part 573 safety recall report

American Lafrance: Electrical System › Alternator/Generator/Regulator

American Lafrance reported this defect to federal regulators on Mar 13, 2003 and put the number of vehicles at risk at 9. The repair is free for as long as the recall stands.

The defect

ON CERTAIN FIRE TRUCKS EQUIPPED WITH HARRISON HYDRA-GEN GENERATOR PUMPS, THE TUBING CONNECTING THE SOFT START TO THE GENERATOR PUMP CAN BREAK AWAY FROM THE FITTING AND SPRAY HYDRAULIC FLUID ONTO THE EXHAUST.

The risk

THIS CAN CAUSE A FIRE THAT COULD ENDANGER PEOPLE IN THE VICINITY, THE VEHICLE ITSELF, AND NEARBY PROPERTY.

The remedy

HARRISON HYDRA-GEN NOTIFIED OWNERS ON JANUARY 15, 2003. DEALERS WILL REMOVE TWO PIECES OF STEEL TUBING AND REPLACE THEM WITH A HIGH PRESSURE HOSE. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITH A REASONABLE TIME SHOULD CONTACT HARRISON HYDRA-GEN AT 1-800-723-3334 OR AMERICAN LAFRANCE/FREIGHTLINER AT 1-800-385-4357.

2 model years covered

Newest first
VehicleComplaintsRecallsFiresCrashes
2002 American Lafrance Eagle0200
2002 American Lafrance Metropolitan0200

What this page is, and what to do next

A recall is not an opinion. It is a Part 573 report a manufacturer is required by federal law to file once it decides a defect poses an unreasonable risk to safety, and it commits them to repairing the vehicle at no cost to the owner. The three passages above are the manufacturer’s own wording as published by NHTSA.

This page describes the campaign. It cannot tell you whether one particular car has already been through the shop — that is tracked by VIN, and only the manufacturer knows it. Check yours at nhtsa.gov/recalls or with a franchised dealer, quoting campaign number 03V089000.

Full record for the 2002 American Lafrance Eagle → · Recalls carrying a do-not-drive advisory → · Where this data comes from →