MY 2006 JEEP WRANGLER HAS DEVELOPED A CONSISTENT FAILURE TO STOP PUMPS AT GAS STATIONS FROM CONTINUING TO PUMP FUEL EVEN THOUGH THE TANK IS FULL. AS A RESULT, GASOLINE IS SPAT OUT FROM THE FILLER NECK OF THE GAS TANK LIKE A BURST FROM A FOUNTAIN, SPLASHING OUT ON THE GROUND, ON THE SIDE OF THE VEHICLE, AND GENERALLY ON ME, THE OPERATOR OF THE GAS PUMP. IT STARTED ABOUT A YEAR AGO, AND IT NOW EXHIBITS THIS BEHAVIOR CONSISTENTLY EVERY TIME I FILL UP. THIS IS A PROBLEM NOT ONLY DUE TO THE CUMULATIVE ENVIRONMENTAL IMPACT OF SPILLING OUT RAW GASOLINE AND OF RUINING CLOTHING AND RESULTING IN CARRYING WITH ME THE STRONG SMELL OF GASOLINE ALL DAY AT WORK AND AT HOME, BUT IT IS ALSO A CLEAR AND APPALLING SAFETY HAZARD WITH RAW GASOLINE SPLASHED AROUND. THE JEEP DEALERSHIP HAS RECOMMENDED A VERY COSTLY REPLACEMENT OF THE ENTIRE GAS TANK ASSEMBLY AT MY OWN EXPENSE AND HAS SAID THAT THIS WILL ONLY TEMPORARILY RELIEVE THE SYMPTOMS, THAT THE DESIGN HAS NOT CHANGED AND THUS THE PROBLEM WILL CONTINUE TO RESURFACE. *TR
2006 Jeep Wrangler complaints
Owner reports filed with NHTSA about this vehicle, newest first and reproduced as filed. They are unverified accounts: one proves nothing, and a pattern across many is the thing worth reading. Back to the full 2006 record →
EVERY TIME I FILL MY FUEL TANK WITHOUT METERING THE FUEL THE LAST GALLON, THE SHUT-OFF VALVE FAILS AND FUEL POURS OUT OF THE FILLER NECK ONTO THE GROUND, JEEP, AND MYSELF IF I'M CLOSE ENOUGH. *TR
EVERY TIME I FILL MY 2006 WRANGLER WITH GASOLINE, IT SPILLS. *TR
GAS TANK OVERFLOW WHEN FILLING AT GAS PUMP. SPRAYS OUT OF FILL TUBE WHEN FILLING. *TR
MULTIPLE INSTANCES OF GAS TANK IN MY 2006 JEEP WRANGLER UNLIMITED OVERFLOWING, DUE TO POSSIBLE CHECK VALVE MALFUNCTION AND/OR IMPROPER DESIGN FROM FACTORY. *TR WHEN FILLING ONES GAS TANK, YOU WOULD EXPECT THE PUMP TO STOP ONCE THE TANK HAS REACHED ITS CAPACITY. HOWEVER DUE TO A FAULTY IN-TANK CHECK VALVE, THE PUMP NEVER GETS THE PRESSURE CHANGE AS A SIGNAL TO STOP THE FLOW. HENCE, EVERY TIME I FILL UP I END UP SPILLING A NOT-INSIGNIFICANT AMOUNT OF FUEL ON THE GROUND. THIS ISSUE IS ABSOLUTELY NOT OPERATOR ERROR, IT IS A KNOWN DEFECT BY JEEP/CHRYSLER.
THE GAS SPILLS OUT EVERYTIME I FILL UP. THE PUMP DOES NOT CLICK OFF UNTIL GAS SPRAYS OUT OF THE FILLER NECK. IT IS NOT THE GAS PUMP BECAUSE THIS IS AN ONGOING PROBLEM AND I FILL UP AND MAY DIFFERENT PLACES. *TR
FUEL SPEWS FROM FUEL TANK DURING FILL UP. FUEL NOZZLE WOULD SHUT OFF NORMALLY UNTIL RECENTLY IT HAS NOW BECOME A PROBLEM. THIS SHOULD NOT HAPPEN AND THIS PROBLEM IS POTENTIALLY VERY DANGEROUS TO NOT ONLY MYSELF BUT TO OTHERS SHARING ADJACENT PUMPS NOT TO MENTION THE ENVIRONMENT. *TR
GAS TANK OVERFLOWS EVERY TIME TANK IS FILLED. *TR
WHILE FUELING VEHICLE AT GAS STATION, FUEL SPLASHES OUT BEFORE FUEL PUMP SHUTS OFF AT FILL UP. REGARDLESS OF GAS STATION OR SPEED AT WHICH PUMP IS SET AT FUEL ALWAYS SPILLS UNTO VEHICLE AND GROUND. IT IS APPARENT THAT THE FUEL TANK'S ROLL OVER CHECK VALVE IS AT FAULT.
2006 JEEP WRANGLER RUBICON - DURING EVERY FUELING THE FUEL TANK WILL OVERFLOW, THIS ALLOWS GAS TO RUN ON THE GROUND AND ON MY PERSON IF STANDING TOO CLOSE TO THE VEHICLE. *TR
WHEN I ATTEMPT TO FILL MY GAS TANK, THE GAS COMES BACK OUT OF THE TANK. I HAVE TRIED THIS BY GOING SLOW & WHEN THE GAS SHUTS OFF, I SHAKE THE JEEP TO GET THE AIR OUT OF THE TANK - WHEN I DO THIS THE AIR POCKET PUSHES GAS BACK OUT OF THE TANK EVEN WHEN I DON'T HAVE THE FUEL NOZZLE STILL IN THE TANK. THIS ISN'T THE FIRST TIME THAT THIS HAS HAPPENED - I PURCHASED THE JEEP IN ST. AUGUSTINE, FL IN JAN., 2011 & I HAD TO GET GAS RIGHT AFTER PURCHASING IT. THE FIRST TIME I HAD THE AUTO SHUT-OFF ON THE GAS FILLER - IT CLICKED OFF & GAS STARTED FLOWING BACK OUT OF THE TANK. AT FIRST I THOUGHT THAT THE GAS FILLER NOZZLE WAS DEFECTIVE, & NOTIFIED THE CONVENIENCE STORE ABOUT THE OVERFLOW - I ASKED FOR SOME "DRY AGENT" TO CAPTURE THE GAS THAT HAD SPILLED OVER. THE ATTENDANT SHUT THE PUMP STATION DOWN, & SAID THEY WOULD CALL SOMEONE TO CHECK OUT THE FILLER NOZZLE. THE NEXT TIME THAT I NEEDED GAS (BACK IN ORLANDO, FL) THE JEEP WAS BACK NEAR EMPTY (FUEL LIGHT "ON"). I USED THE AUTO CLICK-OFF ON THE FILLER - SAME[XXX], DIFFERENT DAY! I HEARD THE "CLICK" OF THE AUTO-SHUT OFF & WITHIN A SECOND, GAS WAS POURING BACK OUT OF THE FUEL NECK OF THE JEEP. PEOPLE WHO WERE PUMPING THEIR OWN GAS HEARD THE FUEL COME OUT OF THE TANK (AND HEARD ME CURSE, LOL!) THEY COULDN'T BELIEVE WHAT THEY SAW. I'M NOT SURE HOW MUCH FUEL POURED BACK OUT OF THE FUEL NECK OF THE JEEP (AND THE TANK FOR THAT MATTER), BUT THERE WAS A POOL OF FUEL ON THE GROUND. I NOTIFIED THE FUEL ATTENDANT OF THE SITUATION & THEY DIDN'T HAVE A
OVER FLOW OF GASOLINE EVERY TIME I FILL UP AT THE GAS STATION. IT HAS BEEN AN ISSUE SINCE I BOUGHT MY JEEP BRAND NEW IN 2006. THE GAS STATION ATTENDANT HOLDS YOU RESPONSIBLE FOR ALL GASOLINE AND EXPECTS IT TO BE CLEANED. I DRIVE A 2006 JEEP WRANGLER X. *TR
DURING RE-FUELING MY 2006 JEEP WRANGLER, FUEL WILL COME BACK OUT OF THE INLET WHEN THE FUEL LEVEL REACHES THE TOP. IT SPILLS NO MATTER HOW SLOW OR FAST I FUEL THE VEHICLE. I HAVE BEEN READING ON INTERNET COMMUNITY SITES THAT THIS IS A LARGE SCALE PROBLEM AND THAT I SHOULD LOG A COMPLAINT. *TR
FAULTY FUEL TANK CAUSES FUEL SPILL EVERY TIME TANK IS FILLED. I BOUGHT THIS JEEP A YEAR AGO AND EVERY SINGLE TIME I'VE FILLED THE TANK IT SPITS BACK FUEL WHEN THE TANK IS FILLED. I WOULD GUESS 4-5 OUNCES OF FUEL GET SPILLED ON THE GROUND EVERY TIME THE TANK IS FILLED. DEALERSHIP DIAGNOSED THE PROBLEM AND SAYS THE TANK IS FAULTY AND NEEDS TO BE REPLACED. *TR
WHEN REFILLING MY JEEP WITH GAS IT OCCASIONALLY OVERFLOWS. I DIDN'T KNOW IF IT WAS A PUMP OR JEEP ISSUE UNTIL I STARTED HEARING MORE PEOPLE HAVING THE ISSUE AND REALIZED IT WAS A JEEP ISSUE AND NOT A PUMP ISSUE. I UNDERSTAND THAT THE 2007-2008S HAVE A TSB AND DJC WILL FIX FOR FREE, BUT MY JEEP IS A 2006 AND HAS THIS PROBLEM AND I AM NOT COVERED. I WOULD LIKE THE TSB TO INCLUDE ALL JEEPS.
IT SEEMS A CHECK VALVE THAT IS PART OF THE FUEL TANK FAILED. REGARDLESS OF GAS STATION, NOZZLE POSITION OR FLOW RATE I ALWAYS GET GAS SPLASH BACK WHEN I FILL UP THE TANK. IT IS MY UNDERSTANDING THAT REPLACEMENT GAS TANKS HAVE THE SAME DEFECT THAT WILL CAUSE THEM TO FAIL IN A SHORT PERIOD OF TIME.
TL* THE CONTACT OWNS A 2006 JEEP WRANGLER UNLIMITED. THE CONTACT STATED THAT AFTER REFUELING THE FUEL TANK, GASOLINE FUEL WOULD SPILL BACK OUT ONTO THE GROUND. THE VEHICLE WAS NOT INSPECTED BY A DEALER NOR WAS IT REPAIRED. THE FAILURE MILEAGE WAS APPROXIMATELY 34,000.
MY GAS TANK WILL OVERFLOW IF I AM NOT INCREDIBLY CAREFUL WITH THE GAS NOZZLE. THIS HAS HAPPENED REPEATED TIMES AND ON ONE OCCASION POURED GAS ON MY SHOES. (I NOW STAND PRETTY FAR BACK WHENEVER I AM FILLING UP) IT HAS ALSO POURED DOWN THE SIDE OF THE JEEP, DISCOLORING THE FENDER AND PAINT, AS WELL AS LEAVING AN APPROXIMATE 1-2 FOOT PUDDLE OF GAS ON THE GROUND AT THE GAS STATION. I'D GUESS ABOUT 1/4 TO 1/3 GALLON OF GAS WILL GUSH OUT EACH TIME IT OVERFLOWS. TO FIX THIS (ACCORDING TO CHRYSLER) WOULD COST BETWEEN $800 AND $1000. HOW IS THIS IN ANY POSSIBLE WAY *NOT* A SAFETY HAZARD???! *TR
MY 2006 JEEP WRANGLER UNLIMITED RUBICON SPITS GASOLINE OUT OF THE FILL SPOUT AT EVERY FILL UP UNLESS MANUALLY SHUT-OFF BEFORE TANK IS FULL. *TR
2006 JEEP WRANGLER AND THE DEATH WOBBLE. JEEP HAS KNOW ABOUT THIS CONDITION FOR SOME TIME NOW AND SINCE MY WARRANTY IS UP AND THEY COULD NOT FIND THE PROBLEM BEFORE IT WAS UP, I AM NOW STUCK WITH IT OR PAY ALOT OF MONEY FOR A ISSUE THAT SHOULD HAVE BEEN ADDRESSED YEARS AGO BY JEEP. EVERY TIME I HIT A SMALL BUMP IN THE ROAD AT 60MPH THE JEEP GOES OUT OF CONTROL AND SHAKES THE VEHICLE UNTIL YOU CAN COME TO A COMPLETE STOP IN THE ROAD AND THEN ITS FINE. ALL YOU HAVE TO DO IS GOOGLE JEEP AND DEATH WOBBLE AND YOU WILL SEE HOW MANY COMPLAINTS ARE OUT THERE. *TR
WHEN FILLING JEEP WRANGLER, THE AUTOMATIC FUEL SHUTOFF FEATURE OF PUMP DOES NOT WORK, AND GAS SPRAYS OUT BRIEFLY BEFORE SHUTTING OFF, SPILLING ON VEHICLE, OPERATOR, AND GROUND. I HAVE HAD TANK REPLACED BY DEALER AT 50,000 MILES, COST OF $350 TO ME. I UNDERSTAND THAT YOU HAVE CLOSED THE INVESTIGATION INTO THIS, AND IF SO, YOU ARE TRULY INCOMPETENT IDIOTS (I'M SORRY, BUT COME ON). THIS IS A DEFECTIVE PRODUCT WITH SAFETY AND ENVIRONMENTAL NEGATIVE IMPACT! EVEN THOUGH I HAVE REPLACED MY TANK AT SOME PERSONAL EXPENSE, I BELIEVE THAT IT IS WITH THE SAME PRODUCT, AND I FULLY EXPECT IT TO FAIL AGAIN IN THE FUTURE. WOULDN'T YOU EXPECT A MODERN VEHICLE, EVEN A "SIMPLE" ONE TO BE ABLE TO FILL WITHOUT GETTING GAS ON YOURSELF, THE VEHICLE, AND THE GROUND?!!! PLEASE CONSIDER RE-OPENING THE CASE; THE IDEA THAT THE INTERNET CREATED THIS PROBLEM IS RIDICULOUS.
JEEP SUDDENLY LOST ALL POWER AT FREEWAY SPEED. ALMOST GOT CREAMED BY SEMI. CHECK ENGINE LIGHT CAME ON. PULLED OVER ON SHOULDER, RESTARTED ENGINE AND LIMPED HOME UNDER 2500 RPM. ANY HIGHER RPM RESULTED IN COMPLETE POWER LOSS. RAN OBD GOT "INTERMITTENT CAM SENSOR". TRIED TO CHANGE SENSOR BUT ASSEMBLY WAS FULL OF METAL SHAVINGS. DID RESEARCH FOUND OUT THAT THE OIL PUMP DRIVE ASSEMBLY IS FAULTY. PART ON BACK ORDER, NO ONE HAS IT. COMMON PROBLEM WITH 05 MODELS DUE TO FAULTY DESIGN. VERY DANGEROUS AND CAN DESTROY ENGINE.
GAS SPEWS OUT OF THE FILLER TUBE JUST BEFORE THE TANK REACHES FULL AND THE PUMP SHUTS OFF. THIS PROBLEM DID NOT APPEAR UNTIL I OWNED THE VEHICLE FOR OVER A YEAR AND NOW HAPPENS AT EVERY FILL UP. *TR
FUEL SPILLS OUT EACH TIME I FILL MY TANK. FUEL PUMP KICKS OFF AS DESIGNED, BUT IS FOLLOWED BY 2-3 CUPS OF GAS SPILLING OUT WITH FORCE THAT COVERS THE PUMP HANDLE, SIDE OF VEHICLE, GROUND UNDER VEHICLE, AND ANYONE STANDING TOO CLOSE. *TR
FUEL OVERFILLS AND SPILLS WHEN FUELING. *TR
WHEN FILLING THE GAS TANK IN MY 2006 JEEP WRANGLER TJ, THE FUEL OVERFLOWS AND SPILLS/SPLASHES ALL OVER THE SIDE OF THE VEHICLE, AND GROUND. JEEP KNOWS ABOUT THIS ISSUE BUT REFUSES TO DO ANYTHING ABOUT IT. *TR
NOTHING LEADING UP TO IT. IT HAPPENS EVERY TIME I FILL THE GAS TANK. IT OVERFLOWS ALL OVER THE GROUND. IT HAS HAPPENED SINCE I BOUGHT MY JEEP BRAND NEW IN 2006. I HAVE DONE NOTHING TO FIX IT EXCEPT NEVER ACTUALLY FILL IT ALL THE WAY I USUALLY STOP ABOUT A GALLON OR TWO SHORT. BUT SOMETIMES DON'T LET GO OF THE PUMP IN TIME AND IT STILL OVERFLOWS. *TR
FUEL SPILLS OUT AT EVERY TIME I FILL UP. *TR
FUEL SPILLS OUT OF FILL TUBE, AFTER PUMP SHUTS OFF. *TR
2006 RUBICON WITH 40K MILES. FUEL SPRAYS OUT FROM THE GASOLINE FILL TUBE AND RUNS DOWN THE OUTSIDE OF THE VEHICLE ONTO THE PAVEMENT EVERY TIME THE VEHICLE IS REFUELED. THE DEALERSHIP SAYS THE FUEL TANK MUST BE REPLACED TO CORRECT THE ISSUE. IT DOESN'T MAKE SENSE TO PAY FOR A NEW FUEL TANK WITH THE SAME DEFECT. THIS IS APPARENTLY A WIDESPREAD ISSUE AND SHOULD BE RECALLED. *TR
TL*THE CONTACT OWNS A 2006 JEEP WRANGLER. THE CONTACT STATED THAT THE VEHICLE WOULD IDLE IMPROPERLY AND STALL INTERMITTENTLY. THE CHECK ENGINE WARNING LIGHT WOULD ALSO ILLUMINATE. THE VEHICLE WAS TAKEN TO A PRIVATE MECHANIC WHO ADVISED THE CONTACT THAT THE OIL PICKUP DRIVE ASSEMBLY WOULD NEED TO BE REPLACED. BOTH THE DEALER AND MANUFACTURER WERE NOTIFIED AND WERE AWARE OF THE ISSUE; HOWEVER, INFORMED THE CONTACT THAT THE PARTS TO REPAIR THE FAILURE WERE ON BACK ORDER. THE VEHICLE WAS NOT REPAIRED. THE CURRENT MILEAGE WAS 29,556 AND THE FAILURE MILEAGE WAS 25,000.
I WOULD LIKE TO COMPLAIN ABOUT A 2006 RHD JEEP WRANGLER I PURCHASED FROM [XXX]. ON 4/01/10. LEMON IS NOT THE WORD. BEFORE DRIVING OFF THE LOT WITH VEH. I NOTICED THE FAN SWITCH FOR THE AC/HEATER ONLY OPERATED ON HIGH SPEED. HOURS LATER THE DEALERSHIP FINALLY REPLACED THE SWITCH FROM SOMEONES PERSONAL VEH. BECAUSE THE SWITCH IS SO HARD TO COME BY APPARENTLY. WITHIN 2 MOS THE SWITCH FOR THE FAN WENT OUT AGAIN. HAD TO WAIT ANOTHER 3 MOS. (ON BACK ORDER) THE GEAR SHIFTER CABLE BROKE NEXT AND HAD CAR TOWED AND REPAIRED. ALSO, IT WAS RUNNING EXTREMELY HOT, I WOULD HAVE TO SHUT VEH. DOWN TO COOL. THEN TO TOP IT OFF ON AUG. 13TH 2010 THE TRANS FELL OUT ON MY WAY TO WORK. I BOUGHT THE VEH ON APR 1ST (FOOLS DAY) AND BOY WAS I FOOLED. I THOUGHT THIS WOULD BE A DEPENDABLE, RELIABLE VEH. FOR MY JOB, THE POSTAL SVC EVEN GIVES $1000 INCENTIVES FOR THEIR CARRIERS TO BUY JEEPS. BIGGEST MISTAKE I'VE EVER MADE. I COULD OF LOST MY JOB TRYING TO DRIVE THIS JEEP IF MY BOSS HADN'T BEEN UNDERSTANDING ABOUT ALL THE BREAKDOWNS AND DOWNTIMES I HAD. I WOULD NOT RECOMMEND A JEEP TO MY WORST ENEMY. JEEP TO ME STANDS FOR JUST EMPTY EACH POCKET. EVEN JEEP WONT STAND BEHIND THEIR VEH. CAN'T BUY EXTENDED WARRANTY FOR A RHD JEEP THEY DESIGNED TO DELIVER MAIL IN. IS THAT A JOKE OR WHAT? I HAVE OWNED NUMEROUS VEH. AND NOT PAID NEAR THE PRICE I DID FOR THIS JEEP AND THIS HAS TO BE THE WORST EXPERIENCE EVER. BE SMART DON'T MAKE THE MISTAKE I DID. IF YOU DO BUY A JEEP BETTER BUY IT BRAND NEW UNDER WARRANTY CAUSE YO
FUEL SPILLS OUT DURING REGULAR PUMPING AT GAS STATION. THIS HAPPENS DURING THE END OF THE PUMPING WHEN THE TANK IS ALMOST FULL. GASOLINE WILL SHOOT OUT OF THE FILLER SPOUT AND ONTO THE GROUND. *TR
I HAVE A 2006 JEEP WRANGLER UNLIMITED, AND ALMOST EVERY TIME I FILL UP THE GAS TANK IT OVERFLOWS, OFTEN SPRAYING A SIGNIFICANT AMOUNT OF FUEL BEFORE THE PUMP SHUTS OFF. THIS DID NOT HAPPEN WHEN IT WAS NEW, BUT HAS BEEN HAPPENING OFF AND ON, GETTING PROGRESSIVELY WORSE, FOR THE PAST 3 YEARS. I BELIEVE THIS PRESENTS BOTH A FIRE HAZARD AND AN ENVIRONMENTAL HAZARD, AND I KNOW THAT MANY OTHER WRANGLER OWNERS HAVE OBSERVED THE SAME PROBLEM. *TR
GASOLINE SPLASH BACK FROM FILLER NECK WHEN FILLING TANK. THIS OCCURS EVERY TIME TANK IS FILLED.
FUEL ALWAYS SPEWS OUT OF TANK WHEN FILLING UP. WILL NOT ACTIVATE PUMP AUTO-SHUT-OFF. EXTREMELY DANGEROUS CONDITION! *TR
FUEL SPITS OUT OF TANK WHEN FILLING NO MATTER HOW YOU FILL TANK . WILL SPIT FUEL ON GROUND ON AUTO FILL OR MANUAL FILL ANY STATION. HAVE HAD FUEL ON MY SHOES AT TIMES MUST STAND BACK AROUND CORNER OF JEEP. *TR
1. REFILLING FUEL TANK. 2. ONCE TANK IS FULL AND PUMP HANDLE TURNS OFF; A SURGE OF FUEL IS SPIT OUT OF THE FUEL FILLER, ONTO THE SIDE OF THE VEHICLE AND ONTO THE GROUND. THIS HAPPENS EVERY TIME I REFILL THE TANK. 3. NO CORRECTIVE ACTION HAS BEEN TAKEN. *TR
EVERYTIME I FILL UP THE JEEP WITH FUEL, IT SHUTS OFF THE PUMP, THEN OVERFLOWS FUEL ONTO THE SIDE OF THE JEEP AND ONTO THE GROUND. *TR
EVERY TIME I FILL UP MY 2006 JEEP WRANGLER UNLIMITED GAS COMES SPILLING BACK OUT AS THE PUMP CUTS OFF. THIS STARTED HAPPENING THIS FALL AND HAS CONTINUED EVERY SINCE. FUEL GETS ALL OVER THE SIDE OF THE JEEP, THE GROUND AND WHEN NOT STANDING CLEAR ON MY CLOTHES AND SHOES. THIS NEEDS TO BE INVESTIGATED BEFORE SOMEONE GETS HURT. *TR
AT EVERY FILL UP ON MY 2006 WRANGLER RUBICON GAS SPITS BACK OUT ONCE IT'S FULL AND ABOUT A 1/2 GALLON OF GAS SPILLS EVERYWHERE AFTER THE AUTOMATIC STOP FUNCTION ON THE PUMPS CLICKS OFF. *TR
I HAVE A 2006 JEEP WRANGLER UNLIMITED 2 DOOR THAT EVERY TIME I FILL THE GAS TANK UP AT THE PUMP IT RELEASES A SUBSTANITIAL AMOUNT OF GASOLINE THROUGH THE INLET AS IT IS TURNING THE PUMP OFF. THIS OCCURS EVERY TIME I FILL MY TANK AND IS VERY DANGEROUS SEEING AS I GET FUEL ON MY SKIN AND THEN HAVE TO GET IN THE VEHICLE W/ MY 4YEAR OLD DAUGHTER. I AM NOT SURE WHAT TO DO TO CORRECT THE FAILURE.
I TRIED STARTING MY 2006 JEEP WRANGLER ONE MORNING AND WHEN I PUT THE KEY IN THE IGNITION IT JUST ROLLED OVER. I REMOVER THE LOCK CYLINDER AND TOOK IT TO THE PARTS DEPARTMENT AT MY LOCAL JEEP DEALERSHIP. THEY TOLD ME NOTHING WAS WRONG WITH IT. UPON FURTHER INSPECTION THEY FOUND THAT THE PIECE CONNECTING THE KEY CYLINDER TO THE SWITCH HAD SNAPPED SOMEHOW. THEY INFORMED ME THE ONLY WAY TO REPLACE THIS CHEAP LITTLE PIECE WAS TO BUY A NEW $400 STEERING COLUMN ( NOT INCLUDING LABOR )AND THAT THIS IS THE THIRD ONE IN THE LAST MONTH WITH THE SAME PROBLEM. IF THAT DOESN'T WAVE RED FLAGS THEN THEY, JEEP, CERTAINLY HAVE NO CONCERN WITH THE QUALITY OF THEIR PRODUCT. *TR
WHEN FILLING UP MY 2006 JEEP WRANGLER RUBICON GAS WILL SPRAY OUT ON INITIAL SHUT OFF OF THE GAS PUMP. I'VE HAD THIS PROBLEM LOOKED AT, BUT WAS TOLD IT WAS NORMAL FOR THAT TO HAPPEN FROM TIME TO TIME. THEN, I COMPLAINED TO JEEP AND THEY ALLOWED THE DEALERSHIP TO SWITCH OUT TANKS BECAUSE MY JEEP WAS UNDER WARRANTY. THIS WAS ONLY A TEMPORARY FIX...GAS STILL SPRAYS OUT!!! *TR
JEEP SPILLS OUT LARGE AMOUNT OF GASOLINE EVERY TIME IT IS FILLED UP. *LN
EVERY TIME I FILL UP MY GAS TANK, IT WILL OVERFLOW AND LEAK GAS ALL OVER THE GROUND AND ALONG THE SIDE OF THE CAR. *TR
MY JEEP IS EXPERIENCING PREMATURE FAILURE OF THE OIL PUMP DRIVE ASSEMBLY (OPDA), WITH ONLY 31,000 MILES ON THE JEEP. THE FAILURE WAS NOTICED WHEN A CHIRPING WAS HEARD COMING FROM THE OPDA UPON ENGINE START UP. I CONTACTED CHRYSLER WHO HAD ME GET THE PROBLEM DIAGNOSED AT A LOCAL JEEP DEALER, WHICH LED TO THE REPLACEMENT OF THE OIL PUMP DRIVE GEAR. THE REPLACEMENT OF THE DRIVE GEAR DID NOTHING TO ELIMINATE THE CHIRPING. THERE WAS SOME WEAR ON THE DRIVE GEAR WHEN IT WAS REPLACED. A SEARCH ON JEEPFORUM.COM INDICATES THE PROBLEM WITH THE OPDA IS A BUSHING THAT ISN'T GETTING OIL, DUE TO A SEAL THAT IS BLOCKING OIL FLOW. THE PART COMES PACKED WITH GREASE, BUT WHEN IT WEARS OUT THERE IS NO LONGER LUBRICATION. CHRYSLER RELEASED A SERVICE BULLETIN (E05) REFERENCE THIS ISSUE, BUT REFUSES TO ACKNOWLEDGE THAT THE OPDA IS OF FAULTY DESIGN AND CONTINUES TO SUPPLY FAULTY OPDA'S WHEN A REPLACEMENT IS IN FACT SUPPLIED. A RECALL SHOULD BE IN PLACE, BUT IS NOT. IN FACT CUSTOMERS ARE LUCKY TO GET ANY ASSISTANCE IN COVERING THE COST OF REPAIRS IF THEY ARE NOT THE FIRST OWNER OR ARE NOT COVERED UNDER THE FACTORY WARRANTY. THIS PROBLEM PLACES ALL JEEP OWNERS WITH 2005 BUILD DATES AT RISK OF ENGINE FAILURE, DUE TO A KNOWN FAULTY FACTORY PART, WHICH COULD RESULT AT ANYTIME, INCLUDING AT HIGHWAY SPEEDS. THIS COULD RESULT IN A TRAFFIC ACCIDENT, FIRE OR BOTH, WHICH IN TURN COULD RESULT IN INJURY OR DEATH OF THE OCCUPANTS OF SAID VEHICLES.
GASOLINE OVERFLOWS EVERY TIME WHEN FILLING TANK ON 2006 JEEP WRANGLER. IT IS RIDICULOUS THAT THIS DANGEROUS ISSUE HAS NOT BEEN RESOLVED. *TR
WHEN REFUELING OUR JEEP THE PUMP DOES NOT SHUT OFF IN TIME SPRAYING FUEL ALL OVER THE SIDE OF THE VEHICLE AND GROUND. TO FIX THIS THE DEALER WANTS TO REPLACE THE FUEL TANK. THIS IS A VERY COMMON ACROSS THE BOARD CHRYSLER PROBLEM THAT THEY ARE NOT OWNING UP TO. *TR
FUEL OVERFLOWS AFTER NOZZLE CUTS OFF WHEN FILLING GAS TANK.
Reading these
NHTSA publishes every complaint as the owner wrote it and investigates only a fraction. Spelling, capitalisation and judgement are the filer’s own. What carries weight is repetition: the same component failing the same way across many filings, and whether the manufacturer eventually opened a recall for it.